1
Installation, Operation & Maintenance CM MAG-P series Manual ENG 2012 ISM0059 REV 01
if
instructions,
including
recommended
precautions, are not followed.
CAUTION
The use of the word “CAUTION” signifies
possible hazards or unsafe practices which
could not result in minor injury, product or
property
damage
if
instructions
and
recommended precautions are not followed.
MAGNETIC
CM MAG-P are magnetic driven pumps.
The use of the w
ord “Magnetic” indicates the
persistent presence of a magnetic field.
Such fields present immediate danger to
individuals having electronic medical devices,
metallic heart valves, metallic prosthetics or
metallic surgical clips.
2 INSPECTIONS
All M PUMPS products unit are inspected
prior to shipping and prepared for safe
transportation.
Upon receipt of CM MAG-P pump, check
usually for any damage which may have
occurred during shipment.
Notify the courier and M PUMPS promptly if
damage has occurred.
3 STORAGE
If the pump is not installed immediately, it
should be protected from exposure to
moisture and dust.
Shipping protections of the ports installed at
the factory, must be kept securely in place.
Storage instruction provided by the driver
manufacturer should be observed.
4 INSTALLATION
Locate the pump on a firm base close to the
liquid source, preferably below liquid level in
such a way to be easily accessible for
maintenance and inspection.
5 OPERATION SAFETY BASICS
Listed below are some of basics you should
keep during mind in addition to your own
company
rules
regarding
installation,
operation and maintenance:
NEVER:
start this pump without proper prime
(casing must be full of liquid)
NEVER:
operate these pumps with the
suction or the discharge valve closed.
NEVER:
run this pump dry over a few
minutes
.
NEVER:
operate pump if there are question
signs of leakage.
NEVER:
change pump condition of service
without
approval
of
your
M
PUMPS
representative.
NEVER:
loosen port connection while system
is under pressure.
NEVER:
attempt to clean the pump while it is
operating.
NEVER:
operate
pump
above
rated
temperature and pressure.
NEVER:
Pump
liquids
containing
ferromagnetic particles of any size, or
substances which will erode or chemically
attack the internal parts of the pump.
If in doubt, please contact your pump supplier
for advice.
NEVER:
Restrict both the inlet and the
discharge lines while the pumps are running.
Restriction of the inlet may cause the pump to
cavitate, leading to loss of efficiency and
rapid wear.
If the pump is to be shutdown for an extended
period, circulate clean water (or other suitable
solvent compatible with pump materials) for
several minutes, to avoid the risk of internal
precipitation or encrustation.