INTRODUCTION

Thank you for choosing the VISTADOOR intercom system. You have 
purchased a high quality system with a stainless steel cover. The elabo-
rate stainless steel covers are made by hand and thus have individual 
characteristics that should be considered a sign of quality. 

NOTES ON CARING FOR STAINLESS STEEL

Please never clean the stainless steel surfaces with standard cleaning 
materials, as these are too harsh. Please simply clean using spray desi-
gned for the cleaning and care of stainless steel. If this is not available 
please use only clear water. 
Brushed surfaces should always be cleaned with the grain and never in 
a circular motion. This will avoid the creation of scratches. 
Failure to observe these notes may lead to discolouration or even to 
corrosion damage in extreme cases.

The system should be assembled by a specialist.

KEY

1  Outdoor unit
1.1  Wall box
1.2 Stainless steel front plate
2  Indicator field
4  Loudspeaker perforations
5  Bell button
6  Microphone
7  Casing screws
8  Lightness sensor
9   Volume potentiometer
10  Dip switch for the opening time of the door opener
11  Dip switch for the ID code
12  Connection terminal door opener
13  Connection terminal power supply
14  Connection terminal signal line
16  Installation aid

SCOPE OF DELIVERY

1x Outdoor unit
1x Wall box
1x Plaster aid
7x Torx screw for front plate (1pc. spare)
3x Installation aid incl. screw
8x Dowel and screw

PREPARATION FOR INSTALLATION

The following lines are required:
Single-family house: 3 lines from the outdoor unit to the indoor unit 
and 2 lines from the outdoor unit to the door opener. 

Multi-family house (from ADV-320): In this case 3 lines are required per 
bell button from the outdoor unit into each residential unit. 
Example ADV-340: 12 lines are required at the outdoor unit for the 
residential units (3 lines each x 4 bell buttons) and 2 lines to 
the door opener.

Up to four indoor units can be connected in parallel per residential unit. 
The connection can either be laid from the indoor station or in a star 
formation from a central point (distribution box).

The lines should be laid in such a way that they are fed out of the wall 
directly behind the relevant outdoor/indoor unit. 

Note: It is also possible to combine video and audio 
components with the VISTADOOR system.

INSTALLATION OF THE OUTDOOR UNIT

The intercom system is designed to be flush-mounted.

Preparation

When removing the front cover, take care that the indicator field and 
the nameplate do not fall out and get damaged.

The outdoor unit should be mounted at a height of approx. 1.5-1.6m 
(middle of unit). If necessary, adjust the installation height and 
location to suit the local conditions.

1.  Remove the six screws from the stainless steel front plate using 

a Torx screwdriver (T10) and then lift it upwards. Now you can 
uncover the wall box by carefully removing the rubber seal and 
taking out the actual outside station.

2.  Hold the wall box straight on the wall and draw around it on the 

wall with a suitable pencil. Take care that the necessary connecting 
cables are in the middle part of the wall box. The cables should not 
be measured too short.

3.  The cable feedthrough can be detached with a sharp knife.

Note

:

The hole for the intercom system should be measured so that the wall 
box fits precisely inside and is flush with the building wall.

4.  In order to anchor the wall box to the wall, first use the holes in 

the base of the wall box to mark the 8 fixing holes in the wall and 
then drill corresponding holes (diameter approx. 6 mm).

5.  Next place the supplied dowels in the holes. The wall box can now 

be affixed with the 4 outer screws. Take care here to ensure that 
the wall box is level; check this if necessary with a spirit level. The 
wall box must also not be twisted.

NOTE

: If the wall box is affixed only insecurely by the screws, the 

wooden frame can be filled along the sides with appropriate glue.

6.  For plastering insert the supplied plaster aid into the wall box. This 

prevents the wall box from being filled with mortar / plaster. When 
plastering make sure that the threaded inserts will not be soiled 
with mortar / plaster.

7.  Insert the outer unit into the wall box. In order to prevent the outer 

unit from falling out, use the supplied installation aid (16). It is 
easily screwed to the wall box using one of the Torx screws and 
holds the outer unit in position.

ADV-300_I-Manual_Fin1.indd   7

29.10.12   11:46

Summary of Contents for VISTADOOR-System ADV-310

Page 1: ...ADV 300 BETRIEBSANLEITUNG OPERATING INSTRUCTIONS MODE D EMPLOI GEBRUIKSAANWIJZING ADV 300_I Manual_Fin1 indd 1 29 10 12 11 46...

Page 2: ...0 DEUTSCH 2 5 6 Abb 1 DIAGRAM 1 ILLUSTRATION 1 AFBEELDING 1 Abb 2 DIAGRAM 2 ILLUSTRATION 2 AFBEELDING 2 1 4 1 1 2 1 2 3 14 11 12 13 10 9 16 1 2 2 2 16 2 8 1 2 Nm ADV 300_I Manual_Fin1 indd 2 29 10 12...

Page 3: ...t 4 Um die Unterputzschale mit der Wand zu verankern markieren Sie zun chst mittels der L cher im Boden der UP Schale die 4 u eren Befestigungsl cher an der Wand und bohren Sie dann die entsprechenden...

Page 4: ...em Kleber f llen 6 Beim Verputzen stecken Sie die mitgelieferte Einputzhilfe in die UP Schale Dadurch wird verhindert dass die UP Schale sich mit M rtel Putz f llt und anschlie end aufw ndig ges ubert...

Page 5: ...h Fachmann beheben lassen Keine eigenen Reparaturversuche durchf hren 2 JAHRE BESCHR NKTE GARANTIE Es wird f r die Dauer von 2 Jahren ab Kaufdatum gew hrleistet dass dieses Produkt frei von Defekten i...

Page 6: ...he wird es besch digt DE Diese Bedienungsanleitung ist eine Publikation der m e GmbH modern electronics An den Kolonaten 37 26160 Bad Zwischenahn Diese Bedienungsanleitung entspricht dem technischen...

Page 7: ...bution box The lines should be laid in such a way that they are fed out of the wall directly behind the relevant outdoor indoor unit Note It is also possible to combine video and audio components with...

Page 8: ...bell button terminal 2 for the bell button above it etc Video is not connected Connecting a door opener The door opener is connected directly to the outdoor station by two lines figure 2 2 no 12 No a...

Page 9: ...SAFETY NOTES The warranty will be null and void in case of damages arising from violations of these operating instructions We are not liable for consequential damages We accept no liability for materi...

Page 10: ...t possible de connecter en parall le jusqu 4 unit s int rieures par unit d habitation La connexion peut tre install e soit depuis la station int rieure ou en forme d toile depuis un point central bo t...

Page 11: ...application du cr pi positionnez l aide l encastrement sur le bo tier encastrable Celle ci emp che que le bo tier encas trable ne se remplisse de cr pi enduit et pr vient un nettoyage fastidieux Veil...

Page 12: ...r un sp cialiste Ce produit doit tre manipul avec pr caution Les coups les chocs ou une chute m me d une faible hauteur peuvent l endommager Temps d ouverture de la g che Les commutateurs DIP fig 2 3...

Page 13: ...ci t m e GmbH modern electro nics An den Kolonaten 37 26160 Bad Zwischenahn Allemagne Cette notice est conforme la r glementation en vigueur lors de l impression Sous r serve de modifications techniqu...

Page 14: ...oeten zo aangelegd zijn dat ze telkens direct achter de overeenkomstige buiten binnenunit uit de wand worden geleid Tip u kunt bij het VISTADOOR systeem ook videocomponen ten combineren met audiocompo...

Page 15: ...orzien en moeten slechts 1 1 met elkaar worden verbonden Opmerking voor versies van meergezinswoningen Per wooneenheid is een 4 polige aansluitklem voorzien De aansluitklem men zijn genummerd Aansluit...

Page 16: ...epogingen uitgevoerd zijn Deze garantie beperkt op geen enkele wijze uw wettelijk rechten als consument Aansprakelijkheidsbeperking De fabrikant kan niet aansprakelijk worden gesteld voor verlies of b...

Page 17: ...5 6 Abb 1 DIAGRAM 1 ILLUSTRATION 1 AFBEELDING 1 Abb 2 DIAGRAM 2 ILLUSTRATION 2 AFBEELDING 2 1 4 1 1 2 1 2 3 14 11 12 13 10 9 16 1 2 2 2 16 2 8 1 2 Nm ADV 300_I Manual_Fin1 indd 17 29 10 12 11 46...

Page 18: ...ADV 300_I Manual_Fin1 indd 18 29 10 12 11 46...

Page 19: ...ADV 300_I Manual_Fin1 indd 19 29 10 12 11 46...

Page 20: ...in bereinstimmung mit den grundlegenden Anforderungen und den brigen einschl gigen Bestimmungen befindet KONFORMIT TSERKL RUNG kann unter folgender Adresse gefunden werden http www m e de download ce...

Reviews: