ENGLISH | VISTUS-VD
17
17
‚ID-CODE‘). This makes it possible to activate the individual outdoor
stations in turn from one indoor unit in order to be able to monitor the
scope of the corresponding outdoor units. The switch is activated on the
indoor station with the ‘monitor’ button.
ID1 = Switch 1 ‘on’, Switch 2 ‘on’
ID2 = Switch 1 ‘on’, Switch 2 ‘off’
ID3 = Switch 1 ‘off’, Switch 2 ‘on’
Note
: ID 4 is not available for the outdoor station. It is reserved for the
outdoor camera. If several outdoor stations are used in parallel then
only one outdoor station can be connected to the external camera.
Door opener time
The DIP switch (Figure A, ‚Door opener time‘) is used to set how long
the door opener should be activated for. The possible settings are 1
second or 5 seconds. 5 seconds is the factory setting and works for
most standard door openers.
Switch ‘off’ corresponds to an opening time of 1 second.
Switch ‘on’ corresponds to an opening time of 5 seconds.
POSSIBLE SETTINGS ON THE INDOOR STATION
The following settings are possible on the indoor station to adjust the
system to your personal circumstances:
Deactivate ring tone/melody (e.g. during the night)
The ring tone/melody can be deactivated, e.g. in order to prevent
disturbance during the night. Either press the mute button on the
indoor unit once briefly. The LED below the mute button lights up red
as a reminder that the melody is deactivated. To activate the melody
again press the mute button again briefly. When the red LED goes out
the melody has been re-activated.
The optical signal (surround light on the talk and door opener button)
remains active, even then the ring tone/melody is deactivated and still
rings. The red LED flashes if the bell is rung while the mute is activated.
NOTE
: If the VTX-BELL module is used then this will also be deactivated
in the silent mode, i.e. the connected receivers will not give a
signal either.
IMPORTANT
: The monitor on the indoor station needs to be
activated for the following settings (e.g. by pressing the screen button).
Otherwise it is not possible to set the talk/volume, brightness, contrast,
colour saturation and melody.
OSD Settings
(VD 607)
The following settings are made via the On-Screen Display (OSD). To
access the OSD, briefly press the menu button (C.8) on the indoor unit.
Each time you press the menu button briefly, it moves to the next menu
item. The plus and minus buttons (C.9 and C.10 respectively) can be
used to adjust the respective value. The values are stored automatically.
The OSD switches off automatically 6 seconds after the last button
press.
NOTE
: The call volume can also be changed directly using the C.12 and
C.13 buttons during the call.
OSD Settings
(VD 603)
The following settings are made via the On-Screen Display (OSD). To
access the OSD, briefly press the menu button (B.9) on the indoor unit.
Each further short press on the menu button jumps to the next menu
item. The plus and minus buttons (B.8 and B.10 respectively) can be
used to adjust the respective value. The values are stored automatically.
The OSD switches off automatically 6 seconds after the last button
press.
Brightness
Colour saturation
Contrast
Speech volume
Ring tone
Bell volume
VISTUS VD-600_I-Manual_210x240_Fin24.indd 17
10.12.19 14:24