background image

ENGLISH  |      ADV-100

7

VISTADOOR VIDEO OUTDOOR UNIT

Thank you for purchasing a VISTADOOR Audio Outdoor Unit. You have 
purchased a high-quality product with stainless steel cover. The stainless 
steel covers are carefully hand-crafted and therefore have features 
unique to each of them and which should be seen as a mark of quality 
in themselves.

How to care for stainless steel

Never clean stainless steel surfaces with standard cleansing agents, as 
these are too abrasive. Clean only using stainless steel cleaner or care 
spray. If none is available, just use clean water.
Make sure you follow these tips on care, otherwise discolouration may 
occur, or even rust damage.

PACKAGING CONTENTS

ADV 110.1 EG

1x One-family external unit
1x Fixing materials
1x Operating and installation instructions

ADV 120.1 EG

1x One-family external unit
1x Fixing materials
1x Operating and installation instructions

Key

1.  External unit
2.  Housing screws
3.  Terminal cover
4.  Screws for terminal cover
5.  Connection terminal
6.   Volume potentiometer
7.   ID switch
8.   Connecting plug for main board/connection terminal
9.  Luminous field
10. Loudspeaker
11.  Name tag
12. Microphone
13.  Cable entry
14. Screws for fixing the front cover in place
16.  Mounting holes
17. Base
18.  Housing upper part

INSTALLATION

The following cables are needed:
One-family house

: 3 cables from the external unit to the internal 

unit, and two from the external unit to the door opener.

Two-family house

: 3 cables per bell push, so 6 cables in total at the 

external station (3 cables in apartment A and 3 cables in apartment B), 
and two cables from the external unit to 
the door opener.

Additional internal units can be connected to the first internal unit in 
parallel. We recommend star wiring for the system, i.e. the cables of all 
devices meet at a star point in the house and are connected together 
accordingly. The power supply unit for the system power supply should 
likewise be mounted at the star point so as not to increase 
the cable length.
The cables should be laid so that they each exit the wall behind the 
relevant external/internal unit. 

NOTE

: You can also use the VISTADOOR system in combination with 

video and audio components. (video requires 4 cables)

NOTE

: Various connection diagrams can be found in the service area 

on our homepage (www.m-e.de).

Connecting the power supply

We recommend feeding in the power supply at the star point, as shown 
on the example connection diagram. Should this not be possible, the 
power supply can also be connected to the internal or external station. 
One power supply unit can supply power to up to 8 audio units. For 
more than eight units, a second power supply unit is needed. This 
should preferably be connected to the most remote station.

NOTE

: Since functions may be adversely affected by interference, it 

is often useful to connect the negative pole of the power supply unit 
output to the equipotential bonding (earthing).

NOTE

: Do not connect the power supply unit to the mains until the 

system has been fully installed. Otherwise short circuits may occur 
during installation that could irreparably damage the units.

NOTE

: The external station is splashproof according to IP44. During 

heavy rain, especially if there are also strong winds, water may 
nevertheless penetrate the housing. We therefore recommend that the 
unit is only mounted in a sheltered location outside. If installation in 
a sheltered location outside is not possible, a weather protective cover 
should be mounted over the external station.

MOUNTING

Before fitting the external station in the desired location, you should 
connect up the system with an internal station for test purposes and 
try it out at the desired location. Furthermore, the wall should be level, 
and when screwing the external station in place make sure that it does 
not warp.

1.  Unscrew the two screws (14) which fix the front cover in place and 

remove them from the external station.

2.  Lift off the stainless steel front cover. To do this, grasp the sides 

with your fingers while pressing the name tag back with both 
thumbs. The large luminous field may become stuck and you may 
need to press it back a bit.

3.  The housing screws (2) and the screws (4) for the terminal cover 

(3) can now be accessed. First, unscrew the screws for the terminal 
cover and place the terminal cover to one side.

4.  Unscrew the 6 housing screws (2) and place them to one side.
5.  Now carefully detach the housing base from the housing upper 

part. The two 6-pin plugs which connect the main board to the 
connection terminals can now be removed.

ADV-100.1 I-Manual_Fin5.indd   7

31.08.20   17:05

Summary of Contents for ADV-100.1

Page 1: ...ADV 110 1 ADV 120 1 BETRIEBSANLEITUNG OPERATING INSTRUCTIONS MODE D EMPLOI GEBRUIKSAANWIJZING ADV 100 1 I Manual_Fin5 indd 1 31 08 20 17 05...

Page 2: ...1 ILLUSTRATION 1 AFBEELDING 1 Abb 2 DIAGRAM 2 ILLUSTRATION 2 AFBEELDING 2 Abb 3 DIAGRAM 3 ILLUSTRATION 3 AFBEELDING 3 1 2 3 3 14 2 16 5 5 9 12 140 160cm 11 10 4 4 5 5 6 7 8 8 18 17 16 13 ADV 100 1 I M...

Page 3: ...enstation heraus 2 Heben Sie das Edelstahlfrontcover ab Dazu fassen Sie es seitlich mit den Fingern und dr cken gleichzeitig mit beiden Daumen das Namensschild nach hinten heraus Evtl klemmt dabei da...

Page 4: ...rt der Au enstation anzuzeichnen 7 Bohren Sie die Befestigungslocher mit einem geeigneten 6mm Bohrer und stecken Sie in jedes Loch einen der mitgelieferten D bel 8 F hren Sie die Anschlussleitung durc...

Page 5: ...wurden Ihre gesetzlichen Rechte als Kunde werden in keiner Weise durch diese Garantie beeintr chtigt Bitte beachten Sie Es besteht kein Anspruch auf Garantie in u a folgenden F llen Bedienungsfehler...

Page 6: ...1 ILLUSTRATION 1 AFBEELDING 1 Abb 2 DIAGRAM 2 ILLUSTRATION 2 AFBEELDING 2 Abb 3 DIAGRAM 3 ILLUSTRATION 3 AFBEELDING 3 1 2 3 3 14 2 16 5 5 9 12 140 160cm 11 10 4 4 5 5 6 7 8 8 18 17 16 13 ADV 100 1 I M...

Page 7: ...equires 4 cables NOTE Various connection diagrams can be found in the service area on our homepage www m e de Connecting the power supply We recommend feeding in the power supply at the star point as...

Page 8: ...ed to terminal 10 If a locking system is used instead of a normal door opener we recommend using the SDO 10 security door opener module This means that the locking system cannot be bypassed by simply...

Page 9: ...airs have been undertaken Customer statutory rights are not affected by this guarantee Please note No claim can be made under guarantee in the following circumstances Operational malfunction Empty bat...

Page 10: ...1 ILLUSTRATION 1 AFBEELDING 1 Abb 2 DIAGRAM 2 ILLUSTRATION 2 AFBEELDING 2 Abb 3 DIAGRAM 3 ILLUSTRATION 3 AFBEELDING 3 1 2 3 3 14 2 16 5 5 9 12 140 160cm 11 10 4 4 5 5 6 7 8 8 18 17 16 13 ADV 100 1 I M...

Page 11: ...fonction Le bloc d alimentation pour l alimentation lectrique de l installation doit tre mont galement au point d toile afin de ne pas augmenter la longueur des c bles Les c bles doivent tre pos s de...

Page 12: ...t tre refoul e quelque peu 3 Les vis du bo tier 2 et les vis 4 du cache du bornier 3 sont pr sent accessibles D vissez d abord les vis du cache du borner et mettez celui ci de c t 4 D vissez ensuite l...

Page 13: ...es syndicats professionnels En cas de doute concernant le raccordement le fonctionnement ou la s curit de l appareil veuillez contacter un sp cialiste Ce produit doit tre manipul avec pr caution Les c...

Page 14: ...1 ILLUSTRATION 1 AFBEELDING 1 Abb 2 DIAGRAM 2 ILLUSTRATION 2 AFBEELDING 2 Abb 3 DIAGRAM 3 ILLUSTRATION 3 AFBEELDING 3 1 2 3 3 14 2 16 5 5 9 12 140 160cm 11 10 4 4 5 5 6 7 8 8 18 17 16 13 ADV 100 1 I...

Page 15: ...e moet ook op het sterpunt worden gemonteerd om te voorkomen dat de kabels nog langer worden De kabels moeten zo worden aangelegd dat deze telkens achter de bijbehorende buiten binneneenheid uit de mu...

Page 16: ...kabels van de externe stroombron naar de deuropener en naar de buitenunit zijn vereist Poort 1 van de deuropener is direct op poort 1 van de externe spanningsbron aangesloten Aansluiting 2 van de deur...

Page 17: ...atig wordt onderhouden De verplichtingen van deze garantie zijn beperkt tot de reparatie of de nieuwe montage van een of ander onderdeel van het toestel en gelden uitsluitend onder de voorwaarde dat e...

Page 18: ...ADV 110 1 ADV 120 1 ADV 100 1 I Manual_Fin5 indd 18 31 08 20 17 05...

Page 19: ...ADV 100 1 I Manual_Fin5 indd 19 31 08 20 17 05...

Page 20: ...ics dass dieses Ger t den folgenden Richtlinien entspricht RoHS 2011 65 EU LVD 2014 35 EU EMC 2014 30 EU Die KONFORMIT TSERKL RUNG kann unter folgender Adresse abgerufen werden http www m e de downloa...

Reviews: