INSTRUCTION FOR INSTALLATION AND USE - LUNA 700-1000-1150-1300-1600-1900H GOLD - GAS
5
1. GENERAL REMARKS
This is a moulding of the closed combustion system, designed for the atmosphere and comfort of
your living-room. It constitutes an efficient source of heat and gives the impression of a real chim
-
ney fire.
The gas with air-vent furnaces are based on the principle of natural extraction from the furnace,
which eliminates flue gas outside and brings in air (oxygen) from outside the house which is neces
-
sary for combustion of the gas. It uses to this effect two concentric pipes. The internal pipe ensures
the elimination of burned gases and the external pipe brings in combustion air. The advantage of
this principle is that the equipment works independently of the atmosphere which predominates
in the house.
2. CONNECTION
This appliance must be connected by an approved installer in accordance with the most recent
regulations in force. On the basis of your order specifications, this appliance is designed for natural
or propane gas.
Read the instructions before installing and using this appliance. Before installing the furnace, please
check the local regulations about this type of furnace (identification of the type of gas, etc.) and
check that the furnace is adapted to your means of installation.
CAUTION
: The furnace must be connected to the type of gas mentioned on the appliance. Never
connect a propane burner to natural gas or vice versa!
It is imperative that the installer sees to the following:
• The appliance must be subject to a water tightness test of the gas and elimination of flue
gases.
• The concentric pipe, if already available, must be working correctly.
• The running of the control valve, lighting of the pilot light, the main burner and the
thermocouple must all be checked.
This appliance has been programmed and factory sealed. The sealed parts cannot be modified. The
appliance may therefore also be installed in watertight accommodation and accommodation equip-
ped with mechanical ventilation. It constitutes ambient heating even in accommodation equipped
with a closed ventilation system.