LUNA 1000DH/CL/CR/DC - 1150DH - 1300DH/CL/CR/DC - 1600DH/CL/CR/DC GOLD - GAS
12
Pic. 5 ROOF EXIT with 90° bends
CAUTION :
if the vertical lenght is over 3 meter longer than the horizontal lenght, you will
need to place a reduction ring of
Ø 60.
Appliance
Ø 150/100 and Ø 200/130
1000 / 1150
1300 / 1600
for each 90° bend substract 1 m horizontaly or add 1 m verticaly.
1000 / 1150
1300 / 1600
for each 45° / 30° / 15° bend substract 0,5 m horizontaly or add 0,5 m
verticaly.
Pic. 5
Fig. 5 ROOF EXIT with 90° bends
Ø 150/100
WITH REDUCTION USVK13 oN APPLIANCE
Aplliance
A (min)
B (max)
C (min)
(A+B+C )max
1000 DH / CL / CR / DC
1,25 m
A+C
B-A-1m
17m
1150 DH
1,25 m
A+C
B-A-1
16m
1300 DH / CL / CR / DC
1,25 m
A+C
B-A-0,5
15m
1600 DH / CL / CR / DC
1,25 m
A+C-1m
B-A
14m
Ø 200/130
without reduction
Appliance
A (min)
B (max)
C (min)
(A+B+C )max
1000 DH / CL / CR / DC
1 m
(A+C) + 8m
B-A-9m
19m
1150 DH
1 m
(A+C) + 7m
B-A-8m
18m
1300 DH / CL / CR / DC
1 m
(A+C) + 6m
B-A-7m
17m
1600 DH / CL / CR / DC
1 m
(A+C) + 3m
B-A-4m
17m
DH = Double Face CL = Corner Left CR=Corner Right DC = Double Corner
DH = Double Face CL = Corner Left CR=Corner Right DC = Double Corner
WITH REDUCTION USVK13
oN APPLIANCE
Summary of Contents for LUNA 1000 CL Gold Gas
Page 22: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 22 LUNA 1150 DH GAS 6 7 ...
Page 43: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 43 ...
Page 46: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 46 15 CE CERTIFICATION ...
Page 47: ...LUNA 1000DH CL CR DC 1150DH 1300DH CL CR DC 1600DH CL CR DC GOLD GAS 47 ...