CAUTION:
Weight and Balance is affected by battery configuration
changes
– ensure within limits before take-off.
WARNING
:
Do not inhale any fumes or gasses resulting from a
battery fire.
Table 8-1 provides technical data of the RES HV batteries.
Batteries technical data
Manufacturer
Emectric GmbH
Type
BM 384
Configuration
96S4P
Battery Voltage
270V-400V
Nominal Voltage
350V
Max continuous current
60 A
Usable Energy
(available energy decreases with high power settings)
3.4
–
4.2 kWh per battery
Battery Weight (each)
~ 24.9 kg (54.8 lbs)
Dimensions (each)
725 x 347 x 82 mm
(28.5 x 13.7 x 3.2 in)
Table 8-1 Battery Technical Data
NOTE:
When operating the RES at higher power settings, the
voltage drop is greater and the minimum cell voltage
will be reached, even though more energy is still
available in the battery. Reducing the electrical load
(via power setting) will result in a rise in the measured
cell voltage.