Using the Pulsar II 

 
The M-Audio Pulsar II microphone outputs a balanced low-impedance signal. It is designed to 
be connected to the mic-level inputs of a mixer channel or a dedicated high-quality preamp. 

As with all condenser microphones, your Pulsar II requires power in order to operate. You will 
need to connect the Pulsar II via an XLR microphone cable to a preamp or mixer channel input 
that su48V phantom power. (Phantom power shares the same XLR cable as the audio 
from the microphone.) In order to avoid pops and surges that can damage components like 
speakers and microphones, always perform the following steps when connecting the mic and/or 
cable: 
 
1.

 

Turn the volume/gain on your preamp and/or mixer all the way down. 

2.

 

Make sure that phantom power is turned off. 

3.

 

Connect the microphone via a high-quality XLR cable. 

4.

 

Turn on phantom power. 

5.

 

Slowly turn up the gain on your preamp and/or mixer. 

 
Before disconnecting the mic and/or cable, repeat Steps 1 and 2.  
 

Cardioid Pattern 

 
Cardioid is the most commonly used polar pattern engineered into microphones. This design 
causes the rear of the microphone to reject incoming sound, allowing the engineer to isolate the 
signal source from other performance elements or background noise by just pointing the mic at 
the sound source. 
 

Microphone Care 

 
Here are a few tips for care of your Pulsar II microphone: 

 

Never subject the Pulsar II to physical shock. 

 

Always use a stand and always use the included hard mount when securing to a stand. 

 

Avoid harmful moisture condensation on the diaphragm when moving the microphone 
between outdoor and indoor environments by allowing the microphone to acclimate to 
room temperature before connection. 

 

Always use high-quality cables in order to avoid electrical problems that may damage the 
microphone's electronics. 

 

Avoid subjecting the Pulsar II to any kind of moisture. In vocal applications, use the 
enclosed windscreen to protect the diaphragm from breath condensation and saliva build-
up. 

 

Never disassemble the Pulsar II microphone. There are no user-serviceable parts inside. 

 

Avoid temperature extremes above 95°F and below 50°F. 

 

Always wipe the Pulsar II exterior down with a soft dry cloth and return it to its case after 
each use to prevent damage from dust. 

 

In the event that your Pulsar II needs more extensive cleaning, lightly dampen a soft cloth 
with water or mild household soap and clean the metal exterior, wiping it completely dry 
when finished. Never spray a cleaning agent on the microphone itself, as the moisture can 
damage the unit. 

Summary of Contents for Pulsar II

Page 1: ...PULSARII User Guide English 3 6 Gu a del usuario Espa ol 7 10 Guide d utilisation Fran ais 11 14 Guida per l uso Italiano 15 18 Benutzerhandbuch Deutsch 19 22...

Page 2: ......

Page 3: ...perfect for stereo use keep in mind that they can also be used in mono applications just like standard Pulsar II microphones The Pulsar II s clean electronics combine with an evaporated gold diaphragm...

Page 4: ...te the signal source from other performance elements or background noise by just pointing the mic at the sound source Microphone Care Here are a few tips for care of your Pulsar II microphone Never su...

Page 5: ...method is excellent mono mixdown compatibility This means that your left and right channels can be summed together into mono with little or no phase related issues such as cancellation or comb filter...

Page 6: ...5 dB A weighted Output Impedance 300 600 Suggested Mic Pre Input Impedance 1 2 5 k Preamp Topology Class A FET transformerless Power Requirement 30 VDC 50 VDC phantom power Connector 3 pin male XLR Di...

Page 7: ...est ndar Pulsar II La electr nica de primera calidad utilizada por Pulsar junto con su c psula ntegramente fabricada con un diafragma de oro vaporizado produce un sonido extraordinariamente transpare...

Page 8: ...ido Por ello el t cnico puede aislar la se al de otras fuentes o del ruido ambiente simplemente orientando el micr fono hacia el sonido Cuidado del micr fono He aqu algunas instrucciones b sicas para...

Page 9: ...s canales derecho e izquierdo pueden agregarse en mono sin que apenas surjan problemas de fase del tipo cancelaci n o filtrado de combinaci n ORTF Este m todo de grabaci n fue desarrollado originalmen...

Page 10: ...cia de salida 300 600 Impedancia entrada previo micro recomendada 1 2 5 k Topolog a de preamplificaci n FET Clase A sin transformador Alimentaci n Phantom 30 VDC 50 VDC Conector XLR macho de 3 patilla...

Page 11: ...si tre utilis s pour des applications mono comme n importe quel micro Pulsar II standard L lectronique propre du Pulsar II se combine un diaphragme en or vapor pour fournir un son doux ce qui en fait...

Page 12: ...du son d isoler la source des signaux d autres sons et bruits de fond simplement en pointant le micro dans la direction de la source sonore Entretien du microphone Vous trouverez ci dessous quelques c...

Page 13: ...de de prise de son offre une excellente compatibilit de mixage mono Ce qui signifie que vos canaux gauche et droit peuvent tre additionn s en mono avec des probl mes de phase r duits ou inexistants te...

Page 14: ...ance de sortie 300 600 Imp dance d entr e micro conseill e 1 2 5 k Topologie de pr ampli FET Classe A sans transformateur Alimentation requise 30 VDC 50 VDC alimentation fant me Connecteur XLR m le 3...

Page 15: ...r l utilizzo stereo tenere presente che possono essere utilizzati anche in applicazioni mono come i microfoni Pulsar II standard L elettronica pulita del microfono Pulsar II si abbina alla capsula in...

Page 16: ...one o dal rumore di sottofondo semplicemente puntando il microfono alla sorgente del suono Cura del microfono Di seguito sono illustrati alcuni suggerimenti per la cura del microfono Pulsar II Evitare...

Page 17: ...patibilit di mixdown mono Ci significa che i canali sinistro e destro possono essere sommati insieme in mono con pochi o nessun problema correlato alla fase quale la cancellazione o il filtro a pettin...

Page 18: ...uscita 300 600 Impedenza di ingresso Pre Mic consigliata 1 2 5 k Topologia preamplificatore FET di classe A senza trasformatore Requisiti di alimentazione 30 VDC 50 VDC alimentazione phantom Connetto...

Page 19: ...t warden Das Zusammenspiel seiner elektronischen Komponenten und der goldbedampften Membran hat einen weichen Sound zu Folge der Pulsar II zu einem idealen Mikrofon f r die Aufnahme von Instrumenten m...

Page 20: ...s Mikrofon auf die Klangquelle gerichtet wird erlaubt es dem Tontechniker die Signalquelle von anderen Instrumenten oder Hintergrundger uschen zu trennen Pflege F r die optimale Pflege ihres Pulsar II...

Page 21: ...n Mono Mixdown Linker und rechter Kanal k nnen ohne nennenswerte Phasenprobleme wie etwa Phasenausl schungen oder dem Kamm Filter Effekt zu einem Monosignal summiert werden ORTF Diese Aufnahmemethode...

Page 22: ...Ausgangsimpedanz 300 600 Empfohlene Mic Eingangsimpedanz 1 2 5 k Vorverst rker Klasse A FET ohne Wandler Spannungsversorgung 30 VDC 50 VDC Phantomspeisung Anschluss XLR Stecker 3 Pin Ma e Durchmesser...

Page 23: ......

Page 24: ...m audio com MANUAL VERSION 1 0...

Reviews: