Trouble-Shooting

If you are having problems using your MM-401 it is probably a
good idea to reread this manual and make sure you have prop-
erly installed the card.  If you can’t find the source of your diffi-
culty check the following typical fixes:

SYMPTOM

The  computer  won’t  boot  with  the  card  in.

Everything is fine without the card.  (This may include strange
error messages.)

SOLUTION

:   

Run  the  INSTALL program  and  make  sure  the

interrupt/IRQ you have set the card to is free.  Also, make sure
the card is recognized at the address selected and that all of the
diagnostics pass.  

SYMPTOM:

The diagnostic program finds the address that the

card is at, but says “No Interrupt Detected.”

SOLUTION:

You are probably running Windows in your system.

Go ahead and quit Windows before running 401TEST.EXE. When
Windows is running, even in the background, it steals the inter-
rupt/IRQ from the MM-401 (even if you run 401TEST.EXE from
the  DOS  Prompt).    Try  running  the  program  from  DOS  —  it
should now work.

SYMPTOM:

My  computer  can’t  find  the  card  when  I  run  my

sequencer program. 

SOLUTION

:   

Same as above.

SYMPTOM

:   

The  card  works  fine  with  my  DOS  programs  but

Summary of Contents for MM-401

Page 1: ...401 MPU 401 Compatible MIDI Interface for the IBM PC and Compatibles 45 E Saint Joseph St Arcadia CA 91006 Tel 626 445 2842 FAX 626 445 7564 Tech 626 445 8495 Http www midiman net techsupt midiman ne...

Page 2: ...401 FCC identification is IMJMM 401 READ THIS READ THIS Included with MM 401 is a factory diskette containing diagnos tic software a number of helpful DOS MIDI utility programs and Windows help files...

Page 3: ...ronome output Runs on any PC at any speed including PC AT 386 486 s Can be reset via a computer hardware reset Accepts MIDI Time Code data in intelligent mode Built in internal timer in UART mode Driv...

Page 4: ...in your appli cations instruction manual Interrupt IRQ and Address Selection It is vital to make sure the interrupt IRQ and address set tings are correctly set on the card The default settings for the...

Page 5: ...er Some older software may not allow you to change the interrupt and will only work on interrupt 2 If this is the case you may need to change the interrupt of conflicting devices instead of the interr...

Page 6: ...tion Hex off off off off 200H off off off ON 210H off off ON off 220H off off ON ON 230H off ON off off 240H off ON off ON 250H off ON ON off 260H off ON ON ON 270H ON off off off 300H ON off off ON 3...

Page 7: ...ff 2 default off ON off off 3 off off ON off 5 off off off ON 7 After setting the interrupt and address as described above you will now need to mechanically install the MM 401 into your com puter Reme...

Page 8: ...ard is firmly and square ly seated into the slot 5 Screw the MM 401 s metal bracket into the screw hole inside the back of your computer 6 Place the cover back on your computer 7 Connect the MM 401 MI...

Page 9: ...t and output First Time Windows Driver Install If there is no current MM 401 Windows MIDI driver installed on your system follow these steps to install MM 401 Windows driv er 1 Start Windows as you us...

Page 10: ...ing the SYSTEM INI file in your Windows root directory and changing the address port listed under the MPU401 DRV for your hardware Warning Be careful when doing this An incorrect setting may result in...

Page 11: ...o is free Also make sure the card is recognized at the address selected and that all of the diagnostics pass SYMPTOM The diagnostic program finds the address that the card is at but says No Interrupt...

Page 12: ...Your Windows application must select the MPU 401 MM 401 as its MIDI Input and Output device This is done from within the application itself SYMPTOM The card works fine with some of my programs but doe...

Page 13: ...e card is somehow connected back to the MIDI In This can be avoided by turning off the MIDI Thru on either your key board or in the application software If this is not the case your computer may be to...

Page 14: ...systems and is the most common setting for MPU 401 compatible cards However if your system includes a SoundBlaster or compatible soundcard it will generally have the same default settings for its MID...

Page 15: ...ot be liable for consequential special indirect or similar damages or claims including loss of profit or any other commercial damage even if its agents have been advised of the possibility of such dam...

Page 16: ...IMAN product we invite you to contact us directly at MIDIMAN 45 E Saint Joseph St Arcadia CA 91066 Or call us at Technical Assistance 626 445 8495 FAX 626 445 7564 http www midiman net techsupt midima...

Reviews: