 WIRELESS DUAL TECHNOLOGY DETECTOR FOR OUTDOOR USE

GENERAL NOTICES AND WARNINGS -  Read carefully before using the appliances

Installation:

 installation and maintenance of these   devices must be carried out by qualified technichians. Correct operations is dictated by the 

correct installation and positioning . The device can be used outdoor  but should be protected from exposure to very high and very low temperatures as 
well as tampering 

Batteries : 

these devices use  batteries, which are potentially dangerous as they are pollutant and  therefore constitute a health hazard if disposed 

incorrectly. Replace the batteries  with same models observing correct polarity as indicated in the instructions. 

Liability:

 MAMI declines all liability to incidents that were consequent to incorrect installation and/or failure to use the devices within the specifictions 

supplied. 

1. CONDITIONS FOR USE AND INSTALLATION CRITERIA:

 

Silentron DualTech is a detector with dual  technology (PIR = passive infra-red de MW = microwave Doppler detector) developed to detect the 
movement  of a  human  in  protected areas and it has been designed specifically for outdoor use. 
The use of Dual Tech technology and the “double alarm” function reduces the possibility of false alarms due to environmental factors typical of an 
outdoor installation (movement of animals of all types, movement of objects and /or meteorological phenomenon).
Correct  positioning and adjustment  of the unit are fundamental:

Brackets and supports:

 An adjustable  mounting bracket (supplied separately)  may be used to further correct the position of the unit.

2. FUNCTIONALITY:
a) General features:

 The device uses three   AA 1.5V   alkaline batteries and   on detection   transmits the alarm via radio, eliminating the need for 

physical wiring. The PIR part of the device is permanently on  and activates the MW part if an  intrusion is detected: the Doppler confirmation of the 
existence of a moving mass in the area generates the alarm state. The detection sequence is displayed by the LED on the front of the device, which 
changes colour (green-orange-red) through the various passages. The detector could   also transmit twice in a 45 seconds window   with 2 different 
codes:  
To reduce battery consumption after every alarm the device is  disabled for a while  and is restored after  no movement is detected  in the area for 2 
minutes. This to reduce consumption in busy areas. A special version will be  available where the 2 minutes are reduced to 5 seconds 

b) Double Alarm function: 

by switching ON the dip 5 the detector transmits a first alarm with a code, and a possible second alarm, detected within 45 

seconds, with a different code, as well as two different detectors. In this case the panel can apply the AND function, giving alarm only after the two 
different transmissions.

c) Adjustments:

 the PIR part can be adjusted in RANGE and in PULSE COUNTS, which provide an activation delay.   The MW may be   adjusted in 

RANGE and DELAY, which is the minimum duration time of the movement detected  required to trigger the alarm (see drawings).

d) Tamper   protection: 

a   magnet fixed to the wall where the mounting bracket is positioned provides tamper   protection. When the detector is 

correctly positioned on the bracket, the magnet closes a reed positioned inside the device: upward or downward sliding and/or the detachment of the 
appliance from the wall causes a "tampering" alarm and the successive "test" state. In the case of detector installation with swivel or angle brackets, 
the magnet must be correctly positioned in one of the three possible positions.
 

e) Opening detection:

 by opening the powered device, a relevant button controls the transmission of tampering independently from the condition of 

the anti-tamper  magnet.

f) Test mode:

 Silentron DualTech is in TEST mode when it is removed from its mounting bracket, where  the magnet is located.

 The test mode  expires  3 minutes after the correct re-positioning of the unit. The LEDs are used to indicate each detection

Note!

 The device will acknowledge use of the magnetic tamper through an internal reed switch. If it detects the rear magnet for 6 seconds after power 

up, the unit will make use of this tamper in its’ normal operation.  Should the device not find the magnet, this tamper operation will be disabled. 
To re-initiate test mode, simply slide the unit up or down on the bracket for 1second.

Note!

 The appliance remains permanently in TEST when the internal TAMPER pushbutton is open (box open)

g) Supervision:

 Silentron DualTech transmits the operating status signal every 40 minutes, which is monitored in the receiver control panels 

h) Low Battery signal:

 the appliance signals via radio to the control panel and locally using 5 beeps that the batteries must be replaced.

3. START-UP – follow these instructions correctly
a) Programming the appliance on the control panel or receiver (also see the instructions of the control panel/receiver used):

·

Open the appliance by loosening the screws on the bottom and open the lid of the battery compartment.

·

Place the control panel in PROGRAMMING mode, in detector learning condition on the desired zone

·

Extract the battery isolating film, powering the appliance: programming will be confirmed by a Beep from the control panel.

·

Terminate the procedure by assigning the name to the detector (if using the HomeGuard). Close the battery compartment.

b) Positioning:

 

Choose the position and the height of installation of the  device  in relation to the area to be protected keeping in mind of the area covered by the device 
PIR section (infra-red detector). It has a central detection beam of over 20m and a series of 4+4 side detection areas of   up to   10m. The highest   
sensitivity of the device is achieved when the intruder crosses the areas perpendicularly. The MW part (microwave) entirely covers the zone, but it is 
activated only after a detection of the infrared (see 2a - Long range version).  
All the detection areas operate on the same level, therefore the protected zone resembles an   anomalous open fan, with the central detection area   
twice the length of others. When the device is   installed vertically (normal position)the detection areas are   parallel to the ground. The height of 
installation must be determined according to the area that should be left not protected to  allow movement of small animals. 
When the device is installed  horizontally it  forms a vertical or diagonal  “curtain” 
 
Do not place the device in direct sunlight to prevent internal overheating (greenhouse effect): this does not damage the appliance but decreases the 
sensitivity of PIR section . Where  possible  protect the  detector from extreme weather conditions  and from gutter overflows

c) Adjustments (see diagram): 

To check the adjustments, use the devices’s LED, which must be placed in TEST state: The green LED indicates the PIR detection: successively it 
changes to orange when the movement is confirmed by the MW part; when the delay time has passed (PT2) the LED turns red indicating the alarm 
transmission. The detection tests must be performed with the device closed. 

·

Adjust the PIR sensitivity (dip-switch 2), with pulse count on 1 (off), limiting the range to what is strictly  necessary.

·

Adjust the sensitivity of the MW part (RANGE - PT1), with activation  time at minimum, as a consequence of the previous adjustment.

·

Close the appliance, position it and check the coverage of the protected area (watch the LED) , by moving the same: for a precise definition of the 
detection  area it is recommended that you move around .Iif necessary  open the unit  and reduce or increase the range and  repeat the previous 
tests.

M000060 

Reviews: