LZR U920 User Manual Download Page 6

6

SAFETY

Do not stare into the 

visible laser beams.

The warranty is void if 

unauthorized repairs are 

made or attempted by 

unauthorized personnel. 

Only trained and qualified 

personnel may install and 

adjust the sensor. 

INSTALLATION AND MAINTENANCE

Avoid extreme

vibrations.

Do not cover 

the front screens.

Avoid moving objects 

and light sources in 

the measurement 

field.

Avoid condensation.

Avoid the presence 

of smoke and fog 

in the measurement 

field.

Avoid exposure to 

sudden and extreme 

temperature changes.

Keep the sensor 

permanently powered 

in environments where 

the temperature can 

descend below 0°C.

Wipe the front 

screens regularly 

with a clean and 

damp cloth.

Do not use aggressive 

products to clean 

the front screens.

Avoid direct exposure 

to high pressure 

cleaning.

CAUTION!

 

Use of controls, adjustments or performance of procedures other than those specified herein 

may result in hazardous radiation exposure.

The device emits invisible (IR) and visible laser radiations.

IR laser: wavelength 905nm; output power <0.10 mW 

(Class 1 according to IEC 60825-1)

Visible laser: wavelength 635nm; output power <1 mW 

(Class 2 according to IEC 60825-1)

The visible laser beams are inactive during normal functioning.

The user can activate the visible lasers if needed. Do not stare into the 

visible beams.

For more information see application note LZR

®

-U920/-U921 Protocol.

Summary of Contents for U920

Page 1: ...ide for software version 0500 and higher refer to tracking label on product LASER MEASUREMENT DEVICE WITH BIDIRECTIONAL BUS COMMUNICATION This user s guide is an informative document and can not be se...

Page 2: ...2...

Page 3: ...djustments of the device LASER MEASUREMENT DEVICE 1 laser sweep emission 2 laser sweep reception 3 LED signal 4 4 holes for M5 screws 5 holes for UNC N 10 screws 6 cable conduit 7 visible laser beams...

Page 4: ...nt range Drill 3 holes as indicated on the mounting template Make a hole for the cable Pass the cable through the cable opening Position the sensor and fasten the screws firmly If the heartbeat mode1...

Page 5: ...elength 905 nm output power 0 10 mW CLASS 1 wavelength 635 nm output power 1 mW CLASS 2 10 35 V DC sensor side to be operated from SELV compatible power suppliers only 5 W 1 8 A max 80 ms 35 V see AN...

Page 6: ...ure can descend below 0 C Wipe the front screens regularly with a clean and damp cloth Do not use aggressive products to clean the front screens Avoid direct exposure to high pressure cleaning CAUTION...

Page 7: ...and connections Check the power supply voltage Verify the outside temperature where the sensor is installed Eventually protect the sensor from sunlight using a cover Wait a few seconds If the LED rem...

Page 8: ...declares that the LZR U920 U921 is in conformity with the European directives 2011 65 EU and 2014 30 EU The complete declaration of conformity is available on our website This product should be dispo...

Reviews: