SHEET 2
1.) DETERMINE DESIRED SHELF SPACING WITHIN
SHELVING SECTION. ASSEMBLE SHELVING AS
DESCRIBED IN THE INSTALLATION SHEET
PROVIDED WITH THE SHELVING UNIT, OMITTING
THE SHELF DIRECTLY ABOVE THE MODULAR
DRAWER UNIT. ONE 12" UNIT REQUIRES A SPACE
OF 13 1/2", ONE 18" UNIT REQUIRES A SPACE OF
19 1/2", ONE 24" UNIT REQUIRES A SPACE OF
25 1/2", AND ONE 36" UNIT REQUIRES A SPACE OF
37 1/2". THIS SPACE IS MEASURED FROM TOP OF
SHELF TO TOP OF SHELF.
2.) ATTACH THE FRONT AND REAR BRACKETS BY
ALIGNING THE TANGS TO THE SQUARE HOLES IN
THE POSTS AND PRESSING DOWN. SECURE
BRACKETS IN PLACE WITH (1) 1/4"-20x1 BOLT AND
NUT AT THE BOTTOM OF EACH BRACKET. WHEN
ASSEMBLING A ROW OF SHELVING WITH
MATCHING MODULAR DRAWER UNITS, THE SAME
BOLT CAN BE USED TO ATTACH ADJACENT
MOUNTING BRACKETS TO AN INTERMEDIATE
SHELVING UPRIGHT.
1/4"-20 X 1"
SLOTTED HEAD SCREW
1/4"-20 HEX NUT
(4 PIECES)
(4 PIECES)
Contact us direct for fast friendly service (800) 477-1255
9117-CA
NOTE: 18" HIGH BRACKETS SHOWN
OTHER SIZES SIMILAR
REAR
FRONT