TELEPHONE CABLE CONNECTION

8

7

6

5

4

3

2

1

T568B

C

A

T5e

16

15

14

13

12

11

10

9

T568B

C

A

T5e

24

23

22

21

20

19

18

17

T568B

C

A

T5e

LN-2400DH

10/100 N

ETWORK SWI

TCH

TELEPHONE/IR DISTRIBUTION

JP1

JP2

REMOVE 

LINKS

 WHEN

ALARM 

INS

TALLED

TO  ALARM

FR

OM  ALARM

LINE 2

LINE 1

18VDC

BY

PASS LINKS

JP1

JP2

M

Security Alarm Panel

If a Security Alarm panel is installed, provision has been made to allow the main Telephone line to pass 

through the Secuirity panel. This enables the security system to take priority over the line in the event of 

an activation.
Using standard two core cable, connect the security panel as shown above. Remove the two “Links” JP1 

& JP2 to allow the phone line to pass through the system.

Main phone line input

Security  

alarm panel

Remove links when 

alarm installed

Telephone Distribution PCB

Optional second  

line input

Telephone line(s) 

Connect the main incoming Telephone 

line as shown below. Provision has also 

been made for the second line as shown

7

Summary of Contents for LN-2400DH

Page 1: ...www lynxnet co nz INSTALLATION MANUAL LN 2400DH Multi Room Distribution Hub M 100310 ...

Page 2: ...TENTS Multi Room Distribution Hub Qty 1 Pc Part Code LN 2400DH Computer Network Patch Cables Qty 8 Pcs Part Code LN CAT5 0 3BL Telephone Patch Cables Qty 8 Pcs Part Code LN CAT5 0 3GY IR Patch Cables Qty 2 Pcs Part Code LN CAT5 0 3RD IR Target Qty 1 Pc Part Code LN IRT IR Emitter Qty 1 Pc Part Code LN IRE 2 M ...

Page 3: ...ty of your Set top box location within the home combined with the balanced sharing of modulated signals All outlets are power pass capable allowing a Set top box to pass power to the Satellite dish The Satellite dish may also be powered from the Amplifier by setting the LNB switch to 13 or 18 volts A 12 volt output is provided through the UHF Input connector to power an optional not included Mast ...

Page 4: ...m 3 2 1 4 3 12 8 9 10 11 3 6 5 7 1 Telephone Alarm cable entry 2 RG6 RG59 Antenna cable entry 3 Mounting Holes 4 CAT5e cable entry 5 Removable door surround 6 230VAC Mains cable entry 7 Antenna Amplifier adjustments 8 RJ 45 Room outlets 9 RJ 45 Telephone ports 10 RJ 45 Infrared Repeater ports 11 RJ 45 Network ports 12 RJ 45 ADSL Modem port 4 ...

Page 5: ...or surround May be rotated and installed as Right or Left hanging door Additional framing maybe added to provide further support NOTE Ensure the case is installed 10mm proud of the framing to allow for the thickness of the plasterboard wall linning 350mm 95mm 10mm 5 ...

Page 6: ...2 LINE 1 18VD C M Cat5e Termination As shown in the above diagram terminate all room outlet CAT5e cables to conform with the T568B colour code standard Using a punch down cron tool start from the right outlet1 finishing on the left outlet 8 The cable clamp is designed to secure 8 cables In the event less than 8 cables are to be installed cables ties may be required INSTALLATION TIP When running ca...

Page 7: ... been made to allow the main Telephone line to pass through the Secuirity panel This enables the security system to take priority over the line in the event of an activation Using standard two core cable connect the security panel as shown above Remove the two Links JP1 JP2 to allow the phone line to pass through the system Main phone line input Security alarm panel Remove links when alarm install...

Page 8: ...tenuation 10dB Gain Includes 12VDC output for optional Masthead Amplifier power UHF1 470 862Mhz UHF Modulator input Adjustable 10dB Anttenuation 10dB Gain SAT 950 2150Mhz Satellite dish input Adjustable 10dB Anttenuation 10dB Gain 2 Satellite LNB voltage select switch 13V Vertical Polarisation Select switch to this position to provide 13VDC to the Satellite LNB from the Amplifier power supply 18V ...

Page 9: ...V power supply 1 5mm 2 TPS Electrical 230VAC Input This Distribution hub includes an internal switch mode power supply A 230V AC connection is required as shown above Use standard 1 5mm TPS cable for this connection NOTE This connection must be done by a registered Electrician 9 ...

Page 10: ...www lynxnet co nz LN 2400DH MULTI ROOM DI STRIBUTION HUB LN 2400DH MULT I ROO M D I ST RI BUT I ON HUB PATCHING M ADSL M COMPUTER NETWORK 10 ...

Page 11: ...www lynxnet co nz PATCHING M M TELEPHONE IR 11 ...

Page 12: ...xnet co nz LN 2400DH MULTI ROOM DISTRIBUTION HUB ROOM OUTLET TABLE Room Outlet Location ie boardroom 1 Kitchen etc Use ie telephone Data IR etc 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 12 ...

Reviews: