background image

Page 4 of 4                                                                                                                                                                                                                                  P/N 11864.00 Rev A 

1

2

3

4 4

3

2

1

N

Receptacle

Plug

G

L1

18 B #12

18 G #11

18 W #13

18 W #25
18 B #24
18 BL #23
18 R #22

18

 W #

 1

5

12

 B 

#1

18

 R 

#4

18

 BL #

3

18

 B 

#2

FIG - 6

1. Remove Shaded Twist Ons

2. Remove Wires At Receptacle

N

G

L1

18

 R 

#4

18

 W #

 1

5

12 W #13

12

 B 

#1

18 G #11

12 B #12

18

 B 

#2

18

 BL #

3

4

4

2
3 3

2

1 1

White

Black

Blue
Red

Remote Blower

Junction Box

Conduit

Receptacle

Hood 

Box

Power Supply

Capacitor

Yellow

Yellow

Motor

Green

Change #12 & #13 TO 12GA Wire (Supplied)

Model LOHE Only

Receptacle

Hood 

Box

Power Supply

 

 

A.

 

Access the hood junction box, remove the designated twist on connectors. 

B.

 

Access the remote blower wiring box by removing the top cover, set aside screws for later use. 

C.

 

Run four wires per local code, in conduit from remote blower to hood. 

NOTE:

 maintain white, black, blue and red color code from blower wiring box to hood connections. 

D.

 

Connect 4-wire from blower to hood with twist-on connectors from step – A; remote white to #13 & 15, remote black to 
#24 black, remote blue to #23 blue and remote red to #22 red.  

NOTE: 

When connecting the hood to power supply, replace the black #12 wire and white #13 wire on hood with the 12 

ga. wires supplied with the ventilator. See Fig – 6. 

  

When remote blower is to be grounded to the Power Supply Main Ground use appropriate wire gage per local 
codes. See Fig – 6. 

  

If the blower is grounded through the Hood the 16 ga Green Pigtail wire at the hood 

Must Be Changed to 12 

Ga, or Appropriate Wire Gage to Comply With Local Codes.

 

CAUTION:

 To prevent malfunction and/or harm to electrical components, connections are to be made per diagram and 

instructions. 

E.

 

Check rotation of blower wheel to be sure it rotates freely and does not rub brackets. 

F.

 

Replace blower top cover and screws from step – B. 

 

 
 