Installation 

Mechanical 

Stand Alone Operation 

The D AD 3260 MiniModule can be used in a stand 
alone application. There are two options for the use 

of the module in this way. 
 

a)

 

Using the R FR 3005 Rack Frame 1 option. This 

allows up to any 10 of the MiniModules to be 
secured onto a rack frame assembly for 19 inch 

rack mounting. This keeps the modules secured, 

organized and out of the way. The R PS 3001 
power brick option or the R FR 3010 option is 

required to power each module. Please refer to 

the R FR 3005 Reference Manual supplied with 
this option for more details. 

 

b)

 

Single Use. The MiniModule can be powered 
independently with the R PS 3001 option and 

used in any location where this functionality is 

required. 

 

 

Caution.

 Care needs to be taken 

when using the module in this way, as 
it is not physically secured. Keep the 

module away from the floor to avoid 

the risk of someone stepping or 
tripping on the unit, and locate the 

unit away from excessive sources of 

heat and any sources or moisture.  

 

If using more than one MiniModule in any 

installation, the R FR 3005/3010 Rack frame 
combination is highly recommended. 

 
 

 

Summary of Contents for D AD 3260 BS

Page 1: ...Series 3000 LYNX Technik AG Brunnenweg 3 64331 Weiterstadt Germany www lynx technik com Reference Manual DAD3260BS 6 x AES3 id to AES3 converter DAD3260SB 6 x AES3 to AES3 id converter MiniModules...

Page 2: ...tten permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Except...

Page 3: ...ranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty a...

Page 4: ...ated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interfer...

Page 5: ...nnections 9 Audio Input Connections 9 Audio Output Connections 9 Audio Connections balanced 9 Power Connections 10 DC Power Connector 10 Installation 11 Mechanical 11 Stand Alone Operation 11 Multiple...

Page 6: ...Reference Manual D AD 3260 Version1 1 Page 6 This Page is intentionally left blank...

Page 7: ...co screw terminal style connections Conversion is active providing 4Vpp nom output level D AD 3260 SB 6 Channels of digital balanced Audio AES3 on 110 Ohm Weco screw terminal style connections are con...

Page 8: ...ure 2 shows the physical layout of the D AD 3260 MiniModule If the module is being used in a stand alone application then the optional power supply R PS 3001 E R PS 3001 U R PS 3001 3 or R PS 3004 is...

Page 9: ...ssary to use a connection tool to secure the BNC video connectors to the module Audio Output Connections The D AD 3260 MiniModule is configured for Weco type audio connections for the balanced AES3 au...

Page 10: ...ower Connector The MiniModule has a captive power lead fitted to the module with a male 5 pin locking bayonet connector This connection provides DC power and also data connectivity to the module Conne...

Page 11: ...3010 option is required to power each module Please refer to the R FR 3005 Reference Manual supplied with this option for more details b Single Use The MiniModule can be powered independently with the...

Page 12: ...ack frame option Each module plugs into a connection bus which provides common power for all modules no R PS external power supplies are needed Remote control and status monitoring of all modules is p...

Page 13: ...nection is solid and locked in place A strain relief is included within the module to prevent excessive strain on the connection Signal connections should be made with care please ensure connections a...

Page 14: ...60 BS Inputs Signal 6 x AES balanced transformer isolated inputs Input Impedance 110 Ohms Connection WECO Return Loss 25dB 32KHz to 100KHz Outputs Signal 6 x AES 3 id unbalanced transformer isolated o...

Page 15: ...dance 110 Ohms Connection Weco Output Level 4 0v p p nominal Electrical Specifications Operating Voltage 5VDC Power Consumption 3 0 VA Connection DC input via 5 pin locking bayonet connector Safety IE...

Page 16: ...l desk power supply module for Series 3000 MiniModules 110 240 VAC input 5V DC output R FR 3004 Mounting Support for 4 MiniModules R FR 3005 Rack Frame 1 This is a basic 19 inch rack mountable frame w...

Page 17: ...3 to AES3 id Converter Model Number D AD 3260 BS Part Number 5 155 003 291 Service If you are experiencing problems or have questions concerning your D AD 3020 MiniModule please contact your local dis...

Page 18: ...Technik can be contacted directly using the information below Address LYNX Technik AG Brunnenweg 3 64331 Weiterstadt Germany Website www lynx technik com E Mail info lynx technik com LYNX Technik man...

Page 19: ...Reference Manual D AD 3260 Version1 1 Page 19 This Page is intentionally left blank...

Page 20: ...Reference Manual D AD 3260 Version1 1 Page 20 Notes...