Lynx C DA 3002 Reference Manual Download Page 7

Reference Manual C DA 3002 Version 3.0

 

 

Page 7  

 

 

Getting Started 

Packaging 

The shipping carton and packaging materials 
provide protection for the module during transit. 

Please retain the shipping cartons in case 

subsequent shipping of the product becomes 
necessary. 

 

Product Description 

The C DA 3002 is a high quality dual 8 bit video 

digital to analog converter designed primarily for 

broadcast and professional applications.  
  

The module has two independent conversion 

channels and each channel accepts 1 SDI input 
signal. Each channel has three modes of operation 

using the shared connections on the front 

connection panel. GBR, YUV or S-Video and 

composite (CVBS) outputs. The module provides a 

re-clocked SDI loop through signal for further use 

downstream. 

 
The 

C DA 3002 

has a variety of features, which include: 

 

Two independent D to A conversion 

channels with separate control  

 

Component (RGB or YUV) or (S video and 
composite) output for each channel 

 

PAL or NTSC operation for each channel  

 

Internal color bars  

 

Internal 4x over sampling (54MHz) 

 

Reclocked SDI loop through output  

 

Local DIP-switches and LED's for control and 
status monitoring.  

 

Microprocessor controlled. 

 

Flash Ram storage for settings.  

 

Remote control interface.  

Summary of Contents for C DA 3002

Page 1: ...Series 3000 LYNX Technik AG Brunnenweg 3 64331 Weizterstadt Germany www lynx technik com Reference Manual C DA 3002 Dual SDI to Analog Video Converter MiniModules V 3 0...

Page 2: ...written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Exce...

Page 3: ...rranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty...

Page 4: ...is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful i...

Page 5: ...nnections 12 DC Power Connector 12 Installation 13 Mechanical 13 Stand Alone Operation 13 Multiple Units 14 Electrical Installation 15 Stand Alone Operation 15 Multiple Units 16 Settings and Control 1...

Page 6: ...Reference Manual C DA 3002 Version 3 0 Page 6 This Page is intentionally left blank...

Page 7: ...input signal Each channel has three modes of operation using the shared connections on the front connection panel GBR YUV or S Video and composite CVBS outputs The module provides a re clocked SDI loo...

Page 8: ...with the rack frame option and host controller The C DA 3002 is part of the 3000 series of MiniModules which offer high quality modularity and flexibility in a very small form factor ideal for applic...

Page 9: ...BNC video connections Module configuration is set via small dip switches located behind an access hole in the bottom of the module If the module is being used in a stand alone application then the opt...

Page 10: ...Reference Manual C DA 3002 Version 3 0 Page 10 Figure 2 Module Layout...

Page 11: ...ectors Connection is self explanatory We recommend the use of high quality video cable suitable for digital video connections to reduce the risk of interference or errors due to excessive cable attenu...

Page 12: ...ules DC Power Connector The MiniModule has a captive power lead fitted to the module with a male 5 pin locking bayonet connector This connection provides DC power and also data connectivity to the mod...

Page 13: ...option is required to power each module Please refer to the R FR 3005 Reference Manual supplied with this option for more details b Single Use The MiniModule can be powered independently with one of...

Page 14: ...05 Rack frame option Each module plugs into a connection bus which provides common power for all modules no R PS external power supplies are needed Remote control and status monitoring of all modules...

Page 15: ...system Please make sure the connection is solid and locked in place A strain relief is included within the module to prevent excessive strain on the connection Signal connections should be made with...

Page 16: ...nels are identical and only one is described below Switch Settings Below the switch settings for the 6 position dip switch are defined Please see the section following the table for more detail on the...

Page 17: ...disabled from remote LED 3 OFF please toggle Dip Switch 1 to reaquire local control Dip Switch 2 This switch selects either RGB or YUV component analog outputs from the module Only active when switch...

Page 18: ...present ON selects signal BLACK OFF selects signal COLOR BARS Factory Preset Condition The C DA 3002 is delivered preset for the following mode of operation Local control ENABLED Composite and S Video...

Page 19: ...ingle alarm LED on the front side of the module which is designed for quick and easy indication of a problem condition in installations where visible access to the bottom of the module is not convenie...

Page 20: ...odule LEDs yellow in the following continuous sequence 3 short flashes Pause 3 short flashes This uses the alarm LED located on the front of the module as well as any module edge LEDs that may be used...

Page 21: ...nal Return Loss 35dB 5 75MHz Signal to Noise 60 dB digital input black Operating Modes independent for each channel Outputs RGB or YUV or S Video and CVBS TV Standard NTSC or PAL selectable Test Inter...

Page 22: ...ing support for 1 MiniModule R FR 3004 Mounting support for 4 MiniModules R FR 3005 This is a basic 19 inch rack mountable frame which can accommodate 10 MiniModules with power bricks R PS 300x or can...

Page 23: ...001 284 Service If you are experiencing problems or have questions concerning your C DA 3002 MiniModule please contact your local distributor for assistance We offer a fixed cost service exchange pro...

Page 24: ...Technik can be contacted directly using the information below Address LYNX Technik AG Brunnenweg 3 64331 Weiterstadt Germany Website www lynx technik com E Mail info lynx technik com LYNX Technik man...

Page 25: ...Reference Manual C DA 3002 Version 3 0 Page 25 Notes...