Functional Diagram 

Figure 1 below is the basic functional diagram for 

the C AD 3110 MiniModule. 
 

 

 
 

 

 
 

 

 
 

 
 

 

 
 

 

                    

                
 

Figure 1- C AD 3110 Functional Diagram 

 
Module Layout 

Figure 2 shows the physical layout of the C AD 3110 

MiniModule. Connections are made through 
standard 75 Ohm BNC video connections. Module 

configuration is set via a small dip-switch located 
behind an access hole in the bottom of the 

module. 

 
If the module is being used in a stand alone 

application then the optional power supply (R PS 1 

E, R PS 1 U or R PS 3001-3) is required to power the 
module (not shown) 

 

Summary of Contents for C AD 3110 - 2

Page 1: ...Ver Series 3000 LYNX Technik AG Brunnenweg 3 64331 Weiterstadt Germany www lynx technik com Reference Manual C AD 3110 2 Analog Video to SDI Converter MiniModules...

Page 2: ...written permission of LYNX Technik AG LYNX Technik AG may have patents patent applications trademarks copyrights or other intellectual property rights covering the subject matter in this document Exc...

Page 3: ...rranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care LYNX Technik shall not be obligated to furnish service under this warranty...

Page 4: ...is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful...

Page 5: ...r Connector 12 Installation 13 Mechanical 13 Stand Alone Operation 13 Multiple Units 14 Electrical Installation 15 Stand Alone Operation 15 Multiple Units 15 Settings and Control 16 Switch Settings 16...

Page 6: ...Reference Manual C AD 3110 2 Version1 3 Page 6 This Page is intentionally left blank...

Page 7: ...ts these into 8 or 10 Bit SDI video signals SMPTE 259M C Three separate SDI outputs are provided The Module is dual standard PAL NTSC and Input detection is automatic One passive loop through of the C...

Page 8: ...Chroma Gain Pedestal and Hue Luma Chroma shaping filter for YC S Video and CVBS modes Luma Chroma Comb filter mode off 3h 5h adaptive Automatic Gain Control mode manual auto reference select CTI Colo...

Page 9: ...re 2 shows the physical layout of the C AD 3110 MiniModule Connections are made through standard 75 Ohm BNC video connections Module configuration is set via a small dip switch located behind an acces...

Page 10: ...Reference Manual C AD 3110 2 Version1 3 Page 10 Figure 2 Module Layout...

Page 11: ...ectors Connection is self explanatory We recommend the use of high quality video cable suitable for digital video connections to reduce the risk of interference or errors due to excessive cable attenu...

Page 12: ...odule has a captive power lead fitted to the module with a male 5 pin locking bayonet connector This connection provides DC power and also data connectivity to the module Connector wiring is shown bel...

Page 13: ...3010 option is required to power each module Please refer to the R FR 3005 Reference Manual supplied with this option for more details b Single Use The MiniModule can be powered independently with th...

Page 14: ...Rack frame option Each module plugs into a connection bus which provides common power for all modules no R PS external power supplies are needed Remote control and status monitoring of all modules is...

Page 15: ...connection Signal connections should be made with care please ensure connections are correct and compatible equipment is feeding receiving the signals from the module or damage can result Caution Only...

Page 16: ...ble for more detail on the switch function Step through test patterns by toggling SW3 within two seconds Only if SW5 is set to OFF Switch Setting Function ON Local control enabled 1 OFF Local control...

Page 17: ...et to OFF this will pass the input video signal Switching twice within two seconds activates the next pattern in the following sequence color bars color bars over red black signal PLL EQ pathological...

Page 18: ...AD 3110 2 Version1 3 Page 18 Auto Store If no parameters are changed for 10 seconds then the current settings will be written into flash memory automatically this can be seen by the front LED flashing...

Page 19: ...Chroma Gain 0dB Pedestal 0 Gain 0dB Hue 0 High Q mode If this is the mode of operation required then no adjustments are necessary Enhanced Operation Control An enhanced set of control parameters and...

Page 20: ...arm LED There is also a single alarm LED on the front side of the module which is designed for quick and easy indication of a problem condition in installations where visible access to the bottom of t...

Page 21: ...identified on the control system it is possible to initiate the locate function and flash the module LEDs yellow in the following continuous sequence 3 short flashes Pause 3 short flashes This uses th...

Page 22: ...tion Parameter settings can be stored with remote operation Test color bars color bars over red black signal PLL EQ pathological Performance Quantization 12 bits for Luma and Chroma Frequency Response...

Page 23: ...odules with power bricks R PS 3001 R FR 3005 Rack Frame 1 This is a basic 19 inch rack mountable frame which can accommodate 10 MiniModules with power bricks R PS 1 or can be extended with the R FR 30...

Page 24: ...5 001 270 Service If you are experiencing problems or have questions concerning your C AD 3110 MiniModule please contact your local distributor for assistance We offer a fixed cost service exchange pr...

Page 25: ...X Technik can be contacted directly using the information below Address LYNX Technik AG Brunnenweg 3 64331 Weiterstadt Germany Website www lynx technik com E Mail info lynx technik com LYNX Technik ma...

Page 26: ...Reference Manual C AD 3110 2 Version1 3 Page 26 Notes...