background image

 FIGURE 2

(7)  Route the power cord through the cable gland

and pressure block. (FIGURE 3)

 FIGURE 3

(8)  Strip approx. 6-8mm insulating part of the

wires from the power cord.

(9) Connect the 

BROWN 

wire to the terminal block 

 L

 

 mark (Live wire).

   Connect the 

BLUE 

wire to the terminal

   block 

 N

 

 mark (Neutral wire)

   Connect the 

YELLOW/GREEN 

wire to the

   terminal block 

 mark (Ground

   wire).(FIGURE 4)

FIGURE 4

(10) Use the pressure block and its two screws to

fix the power cord, then cover back the back
plate.

(11) Secure the Floodlight with its mounting

bracket using the screws provided.

 

    Note: The Floodlight can be installed only

horizontally (see the FIGURE 5a), not

 

    Vertically (see the FIGURE 5b).

 

 

2

HORIZONTAL          VERTICAL

FIGURE 5a & 5b

BULB INSTALLATION

CAUTION 

: Always handle quartz halogen bulbs with

a soft cloth.  Do not touch the bulb with your bare hand
as it will shorten the life of the bulb.

(1)  Do not touch the Floodlight while it is in use or still

hot. Allow it to cool (about 5 minutes) before
touching it.

(2)  Do not use halogen bulb rated higher than 500 watts.
(3)  Disconnect the power cord or wall switch and then

remove cover screw on the top of the unit to open.

(4)  Remove the glass cover.  The cover is mounted on

hinges and will swing open.

(5)  Install bulb by inserting one end first and depressing

until enough clearance is gained to seat the other
end of the socket.  Rotate halogen bulb to assure
proper seating.

(6)  To change a new bulb, lift one end of the bulb to

remove.  Install a new bulb with the same steps
above.

TROUBLESHOOTING

Lights do not light on at all.

l

 

Check power supply.

l

 

Make sure that the bulbs have not burned out.

l

 

Check all wiring and connections.

Others

l

 

The specification of protective shield shall

    consult to local service agent.

SPECIFICATIONS

Power Requirement

AC 220 ~ 240V/ 50Hz

Lighting Load

Max. 500W Halogen
Bulb

Waterproof

IP44

Protection Class

Class I

Power Cord Requirement

H05RN-F, 3G, 1.0mm²

Swiveling Angle

Vertical 90°

                   3         INS122EVSPEB