d. Rotate the Adjustment Handle counter-
clockwise until the pusher block has fully
unthreaded from the Adjustment Screw.
e. Remove the straight pusher and install the
angled pusher by rotating the Adjustment
Handle clockwise to thread the pusher onto
the Adjustment Screw.
f. Once the angled pusher has been threaded
on you can reinstall the Adjustment Screw
Retaining screw. Bronze thrust washer
goes on first, followed by steel washer.
Tighten Retaining screw.
Section I
Setting up and using the Lyman AccuSight
Handgun Sight Tool for Non-1911 Type Pistols
1. Remove slide from pistol. Remove recoil
spring/guide rod and barrel.
Slide MUST be removed from frame
prior to using tool, failure to do so
may result in damage to the frame.
2. Use tape and a marker to mark the current
position of the sight relative to the pistols
slide. Photo A.
3. Make sure all the side clamps are fully
retracted and then place the slide onto the
bottom assembly with the flat part of the
bottom assembly facing you.Photo B.
Helpful Hint
The side clamps are made of steel, you
should protect your slide with a layer of
tape. Photo C.
3
Angled Sight Pusher
Straight Sight Pusher
A
B
C