background image

 

7

Chime  /  Siren:

  Pressing  the  “CHIME”  /  “SIREN”  button  will  activate  the  chime  or  siren  circuitry.   

The LED indicator above the button will be light up simultaneously. Pressing the “SIREN” button again 

will stop siren broadcasting and the LED will be turned off. 

 

Levels of priority muting:

 

MIC1, siren and chime have priority muting functions. MIC1 has the 

highest  level  of  priority  muting  and  can  override  all  other  input  signals.  Siren  has  the  second  level. 

Chime has the third level and can override all input signals except for MIC1 and siren. 

 

REC  input  /  output:

  REC  input  can  connect  to  an  external  source  (CD  player,  tuner,  cassette 

player, etc.) The volume of this input is not adjustable. While recording program signal can send to 

REC input and at the same time signal send out to recording equipment through REC output. REC 

output also can be used for monitoring the other input signals. 

 

PRECAUTION OF INSTALLATION 

   

1.  Do not block ventilation holes. 

2.  Do not use this amplifier if the power cord is frayed or broken. 

3.    The amplifier should not be placed in any of the areas: 

1) Poor ventilation. 

2) Exposed to sunlight directly. 

3) High ambient temperature or adjacent to heat-generating equipment; 

4) High humidity or heavy dust; 

5) Susceptible to vibration. 

4.    Make sure the plug connected to the socket. 

5.    For safety, please use electrical grounding. 

6.    Short-circuit fault happens when short circuit alarm rings during operation, In such case, switch off 

he power immediately and check for short circuit before switching on again.

 

CAUTION 

 

For safety, when “Power switch” is off, please detach the power plug from the power outlet. 

 

The apparatus shall not be exposed to dripping or splashing and objects filled with liquids,   

such as vases, shall not be placed on the apparatus. 

 

To reduce the risk of electric shock, do not remove the cover. 

 

No user serviceable parts inside. Refer servicing to qualified service personnel. 

Summary of Contents for PB-6120

Page 1: ...Mixing Amplifier with Zone Selector PB 6120 PB 6250 PB 6380 USER MANUAL Before operating please read this manual carefully Professional Public Address System ...

Page 2: ...siren Three levels of priority muting MIC1 siren chime 5 LED signal level meter 6 zones output with all call button control Individual volume control for each input master volume bass and treble control Speaker outputs 100V 70V and 4Ω Power supply AC 220V 240V and DC 24V Thermal over load short circuit protection with siren warning Left blank for memo ...

Page 3: ...REAR PANEL 1 Phantom power switch 9 Fan exhaust window 17 Record input 2 MIC1 XLR 6 3mm Input 10 AUX 1 MIC5 switch 18 Speaker output COM 3 MIC2 XLR 6 3mm Input 11 MIC5 6 3mm input 19 Zone output COM 4 MIC3 XLR 6 3mm Input 12 AUX1 Line Input 20 Emergency input terminal 5 MIC4 XLR 6 3mm Input 13 AUX2 Line Input and 24V all call output 6 Output terminals 14 AUX2 MIC6 switch 21 DC24V fuse 7 6 zone out...

Page 4: ...n should be COM 4Ω COM 70V COM 100V Normally the rated power 70V 100V output terminal is used in output connection The connected speaker should have a matching transformer and the gross power of speakers should be less than the rated power of the amplifier Rated Impedance 4Ω output terminal can be used when speakers are fixed closely and the gross impedance of speakers should be 4Ω MIC2 MIC3 MIC1 ...

Page 5: ...led 4Ω 70V 100V together Only choose one pair of output terminals for speaker connection The connection should be COM 4Ω COM 70V COM 100V 4Ω 70V 100V COM COM COM SPEAKERS 8Ω 8Ω 4Ω 70V 100V COM COM COM MATCHING TRANS MATCHING TRANS 4Ω 70V 100V COM COM COM MATCHING TRANS MATCHING TRANS ...

Page 6: ...ailable 6 3mm MIC1 2 3 4 5 6 and XLR MIC 1 2 3 4 MIC1 4 are compatible with two input jacks XLR and 6 3mm MIC 5 6inputs are compatible with AUX 1 2 inputs MIC5 AUX1 and MIC6 AUX2 can be selected through the switches on the back panel MIC1 has the highest level of priority muting function and can override all input signals Note To prevent feedback howling keep volume level down to minimum before co...

Page 7: ...itoring the other input signals PRECAUTION OF INSTALLATION 1 Do not block ventilation holes 2 Do not use this amplifier if the power cord is frayed or broken 3 The amplifier should not be placed in any of the areas 1 Poor ventilation 2 Exposed to sunlight directly 3 High ambient temperature or adjacent to heat generating equipment 4 High humidity or heavy dust 5 Susceptible to vibration 4 Make sur...

Page 8: ...d power MIC1 2 3 4 5 6 80dB S N Ratio AUX 1 2 80dB Bass 12 dB at 100 Hz Tone Control Treble 12 dB at 10 KHz Protection AC fuses 1 DC fuses 1 overload short circuit Temperature MIC1 overrides other input signals Attenuation 0 30 dB SIREN overrides other input signals except MIC1 Attenuation 0 30 dB Muting Function CHIME overrides other input signals except MIC1 SIREN Attenuation 0 30 dB Power Suppl...