background image

26

d. Safety Setting: User can select the system safety mode ( IC CARD or UNLIMITED). If
select IC card, user must use Admin card to setting the main unit, or he/she can not use
setting function. And LCD will display” Please insert IC card”. If select “No Limit”, user can
set the system function without Admin card. ( Default setting is IC CARD” )
Method to of safety setting:Press “ Menu” key, and press key (

) three times switch to

safety setting interface, and then press key

to enter safety setting, press ( ) or ( ) to

select the mode, and press “Menu” key to back, system will exit and save the current
setting automatically

e. System Time setting: the time can be displayed one main unit and microphone LCD.

Display mode: xxxx(year)-xx(month)-xx(day), xx (hour):xx (minute)
Method to setting the system time:Press “ Menu” key, and press key (

) four times

switch to time setting interface, and then press key

to enter time setting, press (

),

( ) or ( ) to select , and press “Menu” key to back, system will exit and save the current
setting automatically

f. Tone setting: There is a warning chime if user open tone setting. Such as operate

without Admin card, microphone battery low and service call.
Method to setting the tone:Press “ Menu” key, and press key (

) five times switch to

tone setting interface, and then press key

to enter tone setting, press ( ) or ( ) to

select , and press “Menu” key to back, system will exit and save the current setting
automatically

g. MIC ID setting: System Mic ID number should be set from [001] to [127]

[Example] If you have 50 units, their ID numbers should be set from [001] to [050],
if any units have the same ID number, the system will not work properly. ID number
of chairman microphone should be [001], one system only allowed one piece
chairman microphone
Method to setting mic id:
Option 1:Press “ Menu” key, and press key (

) six times switch to ID setting

interface, and then press key

to enter AUTO-CODING, press (-) or (+)

Summary of Contents for H-8700

Page 1: ...OWNER S MANUAL INFRARED WIRELESS CONFERENCE SYSTEM Version REV1 0 2016 ...

Page 2: ...f distributor 8 1 5 Infrared transceiver unit 8 1 5 1 Picture of the actual object 8 1 5 2 Features of transceiver unit 9 1 5 3 Schematic diagram of transceiver unit 9 1 5 4 Parameter of transceiver unit 9 1 6 Battery charger 10 1 6 1 Picture of the actual object 10 1 6 2 Features of battery charger 10 1 6 3 Schematic diagram of battery charger 10 1 6 4 Parameter of battery charger 11 1 7 Infrared...

Page 3: ...20 2 5 3 Wiring between IR transceiver unit and main unit when using distributors 20 2 5 4 Caution item 21 2 6 Installation of IR microphone unit 22 2 6 1 Mounting and dismounting the battery 22 2 6 2 Mounting and dismounting the microphone 22 2 6 3 Examples of square arrangements 23 2 7 System setting 23 2 7 1 Main unit setting 23 2 7 2 Microphone setting 28 2 7 3 Video camera tracking function 2...

Page 4: ... units Installation can be done quick and smart without cumbersome arrangements d Fully functions Discuss Video tracing support FIFO 1 2 3 Limit 1 2 3 and chairman only mode microphones in one system up to 127 units e Microphones can be operated on either their built in rechargeable lithium ion batteries or AC power supply Battery life approx 6 hours during speech and approx 30 hours when standby ...

Page 5: ...unit data communication properly the blue LED will flashing rhythmically 4 System menu and function key 5 Audio channel indicator first channel for chairman mic others for delegate 6 Admin card interface 7 Audio Level indicator 8 RS232 data control interface to PC 9 RS232 data control interface to central control system 10 Audio out interface 11 XLR audio output interface 12 RS485 External video p...

Page 6: ...g range Radius 100M Power supply AC110V 50Hz 60Hz AC220V 50Hz 60Hz Consumption Rating 10W Operating temperature range 0 40 degree Dimensions 484 377 85mm N W 8kg 1 3 Infrared conference system microphone unit 1 3 1 Picture of the actual object 1 3 2 Features of infrared delegate microphone a Newly digital design b Portable table moving and microphone pipe can be pull out Extended pipe optional c E...

Page 7: ... should be 1 c Priority function chairman can turn off delegate microphones any time d Chairman only mode Delegate microphone can not be turned on again after chairman microphone press priority button The chairman need quit this mode first and then delegate microphone can be turned on again 1 3 4 Schematic diagram of infrared microphone 1 Annular red indicator lamp to show the microphone state 2 U...

Page 8: ...se 100Hz 12KHz S N Ratio 82dB T H D 0 5 Reference speaking distance 10 30cm Consumption Rating 8W Operating temperature range 0 40 degree Dimensions 168 145 60mm Length of gooseneck 400mm optional N W 1 2kg with battery Battery LIP battery12V 4000MAH 1 4 Distributor 1 4 1 Picture of the actual object 1 4 2 Features of distributor a Adopt impedance balancing branch connector 2 group input 1 group o...

Page 9: ...ble Red 6 LED indicator for group B cable Green 7 DC power jack 8 Power indicator LED 1 4 4 Parameter of distributor Items Parameter Carrier frequency band 4MHz 8MHz Insertion loss computation 1dBM Input Output Impedance 50Ω Input terminal 2 Output terminal 4 Terminal type TNC Dimensions 80 65 20mm Power Supply DC12V 2A N W 670g 1 5 Infrared transceiver unit 1 5 1 Picture of the actual object ...

Page 10: ...oup A cable Red 2 LED indicator for group B cable Green 3 IR signal receiving sensor 4 IR signal transmission sensor 5 IR signal output TNC terminal B 6 IR signal input TNC terminal A 7 Safety rope hole 1 5 4 Parameter of infrared conference system transceiver unit Items Parameter Carrier frequency band 4MHz 8MHz Power supply DC24V from Main unit Rated current 380mA Receiving sensitivity 100dBM Ga...

Page 11: ...y per charging c Intelligent charging management electro circuit to protect the LIP battery d Equipped with extendible handle and pulley easy for moving 1 6 3 Schematic diagram of battery charger 1 Pulley 2 Extendible handle 3 Charging status indicator LED 4 Battery holder 5 Power indicator 6 Power on off switch 7 AC adapter jack AC110V 220V 50Hz 60Hz ...

Page 12: ...t 1 7 2 Features of LIP battery a Excellent safety performance light weight High capacity ratio b Improved safety more resistant to overcharge less change for electrolyte leakage c High Capability Have nearly double the capacity with half the weight of NiCad or NiMH battery packs d Easy to install 1 7 3 Schematic diagram of LIP battery 1 Battery detach lock button 2 Battery locker 3 Negative 4 Pos...

Page 13: ...object 1 8 2 Schematic diagram of AC power adapter 1 AC Power plug 2 Transformer 3 DC plug 1 8 3 Parameter of AC power adapter Items Parameter Input voltage AC110V 220V 50Hz 60Hz Output voltage DC 18V 600mA Dimensions 98 70 55mm only transformer N W 750g ...

Page 14: ... or place them in locations with poor ventilation Doing so traps heat and may result in electric shock or fire If you do not use the units for long periods of time disconnect the power plugs from the outlet Main unit Battery charger Do not disassemble the units Touching the inside of the units may result in electric shock Do not expose the units to any strong shock Do not exposé the units to direc...

Page 15: ...ck Do not expose the units to any strong shock Do not expose the units to direct sunlight heat from heating appliances high temperatures or dust Do not expose the units to high humidity or moisture Water that accidentally enters the inside of the units may result in electric shock malfunction or fire Do not touch the power cables or plugs with wet band Main unit Battery charger Main unit is a clas...

Page 16: ...ons Use only the designated battery charger If the battery leaks and the liquid contacts your skin or clothing immediately flush with clean water If the battery leaks and the liquid contacts your eyes immediately wash thoroughly with clean water and seek medical assistance Do not throw the battery into fire or overheat it Doing so may result in a fire Do not disassemble or modify the battery Do no...

Page 17: ...3 Check quantity of transceiver unit Please check the ceiling height and coverage area of one transceiver unit with above information 2 3 2 to make sure real coverage area can receive the signal well Calculate formula A transceiver quantity B Real coverage area C Coverage area of one transceiver unit A B C Note IR transceiver unit quantity may increase according to the actual installation place Ce...

Page 18: ...rom high power and strong radiation equipment or it may influence the equipment performance c Use it in a well ventilated area 2 4 2 IR main unit to IR transceiver unit Connect two coaxial cables to the TNC terminal transceivers A B of IR main unit the other side connects to the TNC terminal of IR transceiver unit A B If system install more than 4pcs IR transceiver unit the other side should conne...

Page 19: ... main unit to sound system a Mono output Please connect AF OUT interface of IR main unit to input interface of sound equipment by Φ6 3 audio cable b Dual track Please connect XLR out interface of IR main unit to input interface of sound equipment by audio cable 2 4 4 IR main unit to video processor ...

Page 20: ...10 m and the transceiving range is approximately 150 degrees b Infrared operating range of the IR transceiver unit and the microphone unit c When install IR transceiver units on ceiling H the height of the ceiling M D the distance between IR transceiver units M Be sure to overlap the infrared operating areas by approximately 2M ...

Page 21: ... fastened 2 5 3 Wiring between IR transceiver unit and main unit when using distributors If the IR signals of each IR transceiver unit are not in the same phase the transceiving level may decrease To match the signal phase the length of the corresponding cables and should be the same main unit and distributor terminals can not be vacant The main unit can support 16 pcs transceivers maximum ...

Page 22: ... and connect to the center pin soldering it c Insert the shield net and insulating layer to screw nut connector d Connect ferrule to the screw nut connector s anti shedding position e Fasten it with plier 2 5 4 Caution item a Infrared operating distance varies depending on the color of the ceiling and walls b Noise may be generated by interference regardless of the operating distance between the I...

Page 23: ...plifier and cable wiring to this such as speaker output wiring of the digital power amplifier Up to 16 IR transceiver units can be installed of 1 main unit each channel can support 4 pieces transceivers total 4 channels 2 6 Installation of IR microphone unit 2 6 1 Mounting and dismounting the battery a Mounting battery Put the battery on the bottom side of the microphone unit insert the battery in...

Page 24: ... Examples of square arrangements Example Conference room area 30x20 600 m2 Real coverage area 25 15 375 m2 Height of the ceiling 4 5 m Minimum quantity of transceivers A B C see 2 3 3 400 63 6 pieces Please contact us if you need more detailed information during your installation 2 7 System setting 2 7 1 Main unit setting Please insert Admin card to the main unit before setting Default setting is ...

Page 25: ...n off that microphone first LIMIT MODE 2 System only allowed 2 pieces delegate microphones turned on at the same time if other delegate microphones want turn on user should turn off 1 or 2 microphones first LIMIT MODE 3 System only allowed 3 pieces delegate microphones turned on at the same time if other delegate microphones want turn on user should turn off 1 2 or 3 microphones first FIFO MODE 1 ...

Page 26: ...mode setting interface and then press Enter key to enter system mode selecting interface Press or to select the mode FIFO MODE 1 FIFO MODE 2 FIFO MODE 3 LIMIT MODE 1 LIMIT MODE 2 LIMIT MODE 3 press Menu key to back system will exit and save the current setting automatically b Volume setting User can set the system output volume level to match different audio equipment output level from 1 31 defaul...

Page 27: ...etting interface and then press key to enter time setting press or to select and press Menu key to back system will exit and save the current setting automatically f Tone setting There is a warning chime if user open tone setting Such as operate without Admin card microphone battery low and service call Method to setting the tone Press Menu key and press key five times switch to tone setting inter...

Page 28: ...ophone position with the help of this mode Method to setting Press Menu key and press key seven times switch to system setting interface and then press key to enter please turn on the microphone when you debug the microphone position TSQ Microphone transmission signal and RSQ microphone receiving signal can not be 0 the number is bigger the mic position is better TPW is the microphone current TX p...

Page 29: ...e will save the setting and exit automatically b Version User can check the system version by press Menu key and press key or switch to this version interface c Volume output level User can set microphone output volume level with the key VOL and VOL total 31 levels default is level 31 system will save the setting and exit in 5 seconds automatically d Call User can press the key CALL to send servic...

Page 30: ... unit with power switch main unit LCD will off 3 1 2 Main unit LCD display 1 Current system working mode 2 Current output volume level 3 Current date 4 Current time 3 1 3 Panel indicator 1 Status indicator Blue a The indicator will light if there has signal from microphone to main unit b If the microphone battery low less than 10 this indicator will flash c If main unit receive the call service co...

Page 31: ...nd press 1 second microphone OLED display will lighting and show welcome interface Powered off the microphone Please turn off the microphone with power switch hold and press 5 seconds microphone OLED display will off User can turn off the main unit first this time there is no signal and data communicate between main unit and microphone after 15 seconds microphone OLED display will show the message...

Page 32: ...please charge the battery Battery charged by DC power and microphone was powered by external DC power Battery full microphone was powered by external DC power If and icon alternately flashes it means the Li polymer battery is in abnormal state please check the mic microphone use correct battery or the battery contact plate is good 4 Monitor User can monitoring other speakers when insert headphone ...

Page 33: ...low again When battery capacity is not enough to powered the microphone microphone will turn off first and then powered off automatically to protect the battery Microphone OLED display will show Battery Low auto off in XX seconds 3 3 Charge the battery by DC power adapter User can use DC power adapter to charge the battery directly with microphone DC power adapter can charge the battery and supply...

Page 34: ...ed or removed without damage while the charging unit is switched on Charge the batteries to full capacity before using them for the first time Continuously charging the racier will not damage the batteries Batteries can therefore safely be left in their charging positions when they are not used in one month ...

Page 35: ...to the installation diagram Use them within the operating range Connect the cable between the main unit and the IR transceiver units properly Operating time of the microphone unit battery is short The battery is dying 1 Purchase a new battery The microphone unit battery can not be charged The charging lamp does not light The charging lamp is flashing Charging does not complete after 12 hours Are t...

Reviews: