System Planning
Version 1.02, January 2019
Page 8 of 25
4.4
Temperature Specifications
Storage Temperature
Operating Temperature
eCopilot10
-40°C to +80°C
-30°C to +60°C
eCopilot7
-40°C to +80°C
-30°C to +60°C
eBox
-40°C to +80°C
-30°C to +60°C
sBox
-40°C to +80°C
-30°C to +60°C
4.5
Location Requirements
4.5.1
eCopilot10
-
Requires 56 mm of space behind the panel.
-
There is no need for additional space for harness.
-
Choose a position so that the display will be viewable.
4.5.2
eCopilot7
-
Requires 56 mm of space behind the panel.
-
There is no need for additional space for harness.
-
Choose a position so that the display will be viewable.
4.5.3
sBox (Sensor box)
-
The sBox harness needs additional XX mm space
-
Some space should be taken in account also for the pito-static tubes connection
-
Choose a position near CG of plane
4.5.4
eBox (Engine box)
-
It’s recommended to be installed behind firewall (cockpit side)
-
The eBox harness needs additional XX mm space
-
Choose a position near CG of plane
4.6
Grounding and power supply requirements
High current consumers (radio, transponders,…) must be separated from eCopilot system
with separate power line.
Never use airframe as a source of the ground. Air frame must be grounded only on one
place, where is connected to the battery. Currents through airframe are not recommended.
4.7
Cooling Requirements
Currently there are no cooling requirements. If possible, ventilation should pass through the
instrument panel to exchange some warm air. That will drop the temperature behind the
panel a few degrees.
4.8
Mounting Requirements
Most LXNAV units are fastened with screws.
Summary of Contents for eCopilot10
Page 3: ...7 1 Export Diagnostic Files 22 8 Revision History 23 ...