Rev #02
Version 1.0
November 2020
Page 10 of 18
While flying QNH display will looks like next picture.
QNH display will be automatically closed few seconds after last button was pressed.
5.3
Setup mode
Long press middle button to enter setup mode. Setup is used to configure your Airdata
indicator.
A setup menu with following options will be displayed:
Display
– use this menu to set brightness, customize numerical parameters, set theme
color and needle size
Airspeed
– Define speed markings, airspeed calibration table and method for true
airspeed calculation.
Vertical speed
– change vertical speed filter and total energy compensation, if needed.
Temperature
– define temperature offset.
Battery
– select chemistry of battery, which is being used for ADI in order to have
proper battery indication
Warnings
– ADI can display user defined warnings for speed and altitude.
Units
– define system of measure.
System time
– enter current time and data for recording purposes.
Password
– used to reach system setup and various calibrations.
When SD card is inserted all settings will be copied to it once you exit setup
mode. Settings are stored in file named settings.bin. Insert such SD card to other
ADI and you will be prompt to copy settings from SD card to device. With this
method you can easily duplicate settings.