LW MEASUREMENTS WPB 13lb Instruction Manual Download Page 2

 

SAFETY PRECAUTIONS 

All  safety  messages  are  identified  by  the  following  words  "

WARNING

"  and 

"CAUTION". These words mean the following: 

 

 

 

 

 

 

 

When  using  the  scale/balance,  the  following  safety  precautions  should  always 

be followed. 

 

 WARNING 

Use only the AC adapter with the scale/balance. Other adapters may cause 

damage.   

 

 CAUTION 

 

 

Avoid  installing  the  scale/balance  in  direct  sunlight;  this  may  cause 

malfunctions.   

 

Keep scale in room temperature, away from hot temperature. 

 

Avoid shock impact and loading over capacity.    Do not keep heavy object 

permanently on the platform. 

 

If  scale  is  not  used  for  an  extended  period,  keep  it  clean  and  stored  it  in 

plastic package. 

 

Replace all batteries at the same time 

– Do not replace only a portion of the 

6 batteries as this may cause a malfunction. If the scale  is not to be used 

for a long period of time, remove all batteries from the battery compartment 

to avoid leakage, which may cause damage to this scale.

 

 

Do not use scales onto the carpet base, it may cause scales inaccurate and 

need re-calibration. 

 

 
 

1

 

 

              SPECIFICATIONS 

 

Model number 

Capacity 

Division 

WPB 13lb 

6000g/13lb 

0.2g/0.0005lb 

WPB 33lb 

15000g/33lb 

0.5g/0.001lb 

        Platter 

210x160mm 

        Net/gross weight 

2500g/2900g 

 

       

Package 

Standard carton: 30.5×26.5×18.5 (cm

3

4 Units in one box: 55×32.5×41.5(cm

3

Operating Temperature 

0-40

(32-104

 

     

Power source 

6 AA dry cells or AC/DC 

Adapter 9V/100mA 

 
 

Counting procedures 

1. 

Press 

[ON/OFF]

 to turn on the scale.     

2. 

Wait for "0" to appear on the display. 

3. 

If necessary, press 

[ZERO] 

key to set the display to “0” 

4. 

Press 

[PCS]

 key to put the scale in PCS mode. ,the display   

                  will show P=X X       

5. 

Press 

[UNIT] 

key to select XX value (10, 20, 50, 100) 

6. 

Place a given number of samples of an item on the pan (the   

Sample Size should be 10, 20, 50 or 100 pieces).   

7. 

Press

 [PCS] 

key to accept sample quantity

the display   

                  will show PASS. 

8. 

Start counting by adding weight on the scale. 

9. 

Press

 [UNIT] 

key to return to the weighing mode. 

 

NOTE:  The  total  sample  weight  should  be  >  10e  and  unit 
sample weight > 0.5d. 

 
 

6

 

WARNING

 

Important  information  to  alert  you  to  a 
situation  that  might  cause  serious  injury  and 
damage  to  your  property  if  instructions  are 
not followed. 

CAUTION 

Important  information  that  tells  how  to 
prevent damage to equipment. 

Reviews: