background image

INSTRUCTION MANUAL

13C20

SAVE THIS INSTRUCTIONS

LED-BP-SLIM Series

  1.  To prevent electric shock, switch off the mains power supply until installation is complete and AC 
       power is supplied to this product.

  2.  This product requires an un-switched AC power supply of 120-277V, 50/60Hz.

  3.  Make sure all connections are in accordance with the National or Canadian Electrical code and 
       any local regulations.

  4.  To reduce the risk of electrical shock, disconnect both normal and emergency power supplies 
       and connector of this product before servicing. 

  5.  It can provide minimum 90 minutes illumination under the emergency mode.

  6.  

The product is UL Listed for field installation, and use with grounded.

  7.  The LED-BP-Slim units are suitable for use in dry or damp locations. Do not mount in or near 
       gas, heaters, air outlets or other hazardous location.

  8.  Use this product in 0°C

 minimum, 

55°C

 

maximum ambient temperatures (Ta).

  9.  Do not attempt to service the batteries. A sealed, non-maintenance battery is used that is not 
       field replaceable. Contact the manufacturer for information or service.

10.  

The use of accessory equipment not recommended by the manufacturer may cause an unsafe 

       condition and void warranty. 

11.  Do not use this product for other than intended use.

12.  Installation and service should be performed by qualified service personnel.

13.  This product should be mounted in locations and at heights where it will not readily be subjected 
       to tampering by unauthorized personnel.

E206507

BC

IMPORTANT SAFEGUARDS

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

LINEAR EMERGENCY EQUIPMENT
UNIVERSAL INPUT 

THIS PRODUCT CONTAINS A RECHARGEABLE LI-ION BATTERY.
THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

Li-ion

Summary of Contents for LED-BP-SLIM Series

Page 1: ...tlets or other hazardous location 8 Use this product in 0 C minimum 55 C maximum ambient temperatures Ta 9 Do not attempt to service the batteries A sealed non maintenance battery is used that is not field replaceable Contact the manufacturer for information or service 10 The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition and void warranty 11 Do not use...

Page 2: ...fter installation Drill a 1 2 12 mm hole for mounting the LTS Connect the wires from LTS to the LED BP SLIM model according to the wiring diagram on page 3 INSIDE THE LUMINAIRE LED test switch LED BP SLIM XX TB LED BP SLIM MODEL SPECIFICATIONS MODEL EMERGENCY OUTPUT CONSTANT 4 5 WATTS 13 5 WATTS LED BP SLIM 4 5W LED BP SLIM 4 5W TB VOLTAGE OUTPUT 5 200 VDC 15 300 VDC LED BP SLIM 9W LED BP SLIM 9W ...

Page 3: ...LUMINAIRE FOR DC LED LOAD N L L IN L OUT LED Test Switch Red White LED DRIVER N L Red White LED Test Switch LED LOAD LED LED Red Blue Blue White Red Blue White Input Output Output Gray White Black Green Yellow Switch Black White Black HOT Common GND LINEAR EMERGENCY EQUIPMENT Green Yellow N L L IN L OUT LED Test Switch Red White LED Test Switch N L Red Blue Blue White Red Blue White AC LED TUBE BU...

Page 4: ...es out 1 800 982 4587 www lvscontrols com LED BP SLIM 4 5W TB LED BP SLIM 9W TB Item No L1 mm inch 200 7 87 W mm inch H mm inch 260 10 24 345 13 58 410 16 14 190 7 48 250 9 84 335 13 19 400 15 70 30 1 18 22 0 87 30 1 18 22 0 87 30 1 18 22 0 87 30 1 18 22 0 87 M Mounting mm inch LED BP SLIM 13 5W TB LED BP SLIM 18W TB Dimension unit mm inch LED BP SLIM 4 5W LED BP SLIM 9W Item No L1 mm inch 258 10 ...

Page 5: ...ys after initial power on Then monthly tests will be performed every 30 days b Annual Auto test will occur every 52 weeks after initial power on Monthly Auto Test The Monthly Auto Test shall be executed every 30 days and will test Normal to emergency transfer function emergency charging and discharging conditions are normal Monthly test time is approximately 30 60 seconds Annual Auto Test Annual A...

Page 6: ...uminaire Lumens per Watt efficacy in Rated Data specifications F Multiply luminaire Lumens per Watt by Emergency rated output of the ELBP XX S series Refer to the table below 3 Determine Suitability of Means of Egress Lighting Levels Using industry standard lighting design software with the IES files for the emergency luminaires verify that the above calculated emergency lumens are sufficient to meet ...