background image

STEREO POWER AMPLIFIER M-700u

1

Precautions

Installation place

Install this unit in a location where good ventilation and heat 
radiation is assured.
Especially, placing this unit where direct sunlight is present, 
where the temperature rises excessively high such as close to 
a heater, or where it is humid or dusty may cause a malfunc-
tion even if heat is efficiently released.

Ventilation holes

Do not block the ventilation holes of the top and bottom pan-
els. If the amplifier is installed on a rack or the like, secure 
ample space for cooling and leave the door open. Do not pile 
up other things on the amplifier and never put articles on it. 
Failure to observe this may cause a malfunction.

Note:

For heat dispersal, do not install this equipment in a confined 
space such as a book case or similar unit.

Precautions in connecting with other 
components

When connecting this product with a control amplifier and 
such, be sure to turn off the power of this product and all oth-
er connected devices. Failure to observe this may generate 
a strong noise resulting in speaker damage or a malfunction.
The pin-plug to be inserted in each input terminal of this unit 
shall be pushed in firmly. If the grounding terminal is inade-
quately connected, noises including hum may be generated, 
resulting in an adverse S/N ratio.

Cautions in connecting speakers

When making speaker system connections, exercise extra 
care not to short-circuit between 

 and 

 of the speaker 

terminals and speaker input terminals of this unit.
If a large signal is applied to the amplifier with its circuit left 
short-circuited, a large current may be passed through the 
output circuit and cause a malfunction.

The sound is not generated shortly after 
the power supply is turned on.

This amplifier is equipped with a time muting circuit in order to 
separate the output circuit. Therefore, no sound is generated 
shortly after the power supply is turned on.
If the volume control is moved to a high sound level before 
the time muting circuit is canceled, a large sound is suddenly 
generated. Please be advised that the volume control of the 
input device such as a control amplifier shall be set to a low 
level at first and adjusted according to your taste after sound 
comes out of the speakers.

Protection circuit

This product is equipped with a protection circuit that is ac-
tivated upon detection of overcurrent, abnormally high tem-
perature, and DC drift to protect the amplifier and speakers.
When the protection circuit is activated, the output to the 
speaker terminal is shut off and the standby indicator lights 
up to show that this product is in the standby state. Please 
consult your dealer when the protection circuit is sometimes 
activated even after turning off the switch, disconnecting the 
power plug from the wall outlet, and connecting it again after 
a while.

Repair and adjustment

When repair and adjustments are needed, please ask the 
dealer where you bought the unit.

Cleaning

For cleaning, use a piece of soft cloth to wipe the unit such as 
cleaning cloth. When the dirt is hard to remove, use a small 
amount of neutral detergent to wipe, and then wipe the unit 
with dry cloth. Do not use a solvent like benzine or thinner 
because such a substance can often damage the exterior.

*  

Note

Wall

*

*

*

Exercise extra care when this unit is unpacked, assembled, 
transported, and installed because this unit is heavy.

SAFETY CAUTIONS

CAUTION

Summary of Contents for M-700U

Page 1: ...Owner sManual STEREO POWER AMPLIFIER M 700u...

Page 2: ...Contents Precautions 1 Features of This Unit 2 Names and Functions 4 Connections 8 Block Diagram 12 Specifications 13 Before Asking for Repair Services 14...

Page 3: ...current may be passed through the output circuit and cause a malfunction The sound is not generated shortly after the power supply is turned on This amplifier is equipped with a time muting circuit in...

Page 4: ...tion the input stage of the error detection circuit is 3 parallelized to improve distortion and noise BTL connection mode The BTL connection mode with use of 2 units of this product has achieved a hig...

Page 5: ...o the spiral wrap shielding on each core and the non plating processing on the core wire High grade analog meter Large sized analog meter with shower light is equipped Light OFF meter OFF is selectabl...

Page 6: ...standby state to operation state When the main power switch on the rear panel is turned on to set this unit to the standby state turn this switch on Then this unit is set to the operation state When...

Page 7: ...lights ON power meter display ON left The setting of the display switch is memorized in both STE REO and BTL MONO respectively 7 BTL indicator BTL Lights when the BTL selection switch on the rear pane...

Page 8: ...the front panel lights yellow to show that this unit turns to the standby state When this switch is turned off the standby indicator on the front panel turns off to show that the main power is turned...

Page 9: ...d to this unit When BTL MONO is selected this unit acts as a monaural power amplifier Therefore either right or left speaker sys tem can be connected exclusively If stereo playback is desired another...

Page 10: ...ed cable Please be very careful to prevent wrong connection between right and left channels If the right and left channels are con nected reversely the localization of sound images is deterio rated th...

Page 11: ...00u for the right channel Securely connect the terminal of the speaker system to the red SPEAKERS L terminal BTL of this unit and the terminal of the speaker system to the red SPEAKERS R terminal BTL...

Page 12: ...10 CONTROL AMP SPEAKER SYSTEM L R L R REMOTE CD SACD PLAYER CD SACD PLAYER L R L L R R Connections Normal stereo playback...

Page 13: ...STEREO POWER AMPLIFIER M 700u 11 CONTROL AMP CD SACD PLAYER CD SACD PLAYER L R L R REMOTE SPEAKER SYSTEM L R R R L L Set to BTL MONO Set to BTL MONO BTL stereo playback...

Page 14: ...OWER SWITCH AC RELAY 1 AC RELAY 2 TRANS AMP TEMP REG ODNF AMP RECT OP RECT ODNF RECT RELAY RECT PWR RECT PWR RECT COM TRANS CONTROL OUT SP L SPEAKER OUT L SPEAKER OUT R OUT SP R DC OC PRT TEMP PRT DC...

Page 15: ...20kHz 0 3 0dB 1Hz 130kHz S N ratio 115 dB IHF A weighted input short Damping factor 350 Attached equipment Main power switch Operation switch Input switch BTL selection switch Phase inverter switch Po...

Page 16: ...e minimum position Adjust the output level No sound is generated on one side The connecting cable is not connected on one side only Make cable connections securely Sound is generated but the sound vol...

Page 17: ...STEREO POWER AMPLIFIER M 700u 15 MEMO...

Page 18: ...16 MEMO...

Page 19: ......

Page 20: ...LUXMAN CORPORATION JAPAN AG00987E35A Printed in China...

Reviews: