7.2

 

Control Panel Navigation 

Access the control panel functions using the four panel buttons located directly underneath the display 

[6]

From left to right: 

 

Button 

Function 

<MENU> 

accesses the menu and scrolls through the menu options 

<UP> 

scrolls through the menu options in ascending order, or increases a numeric value 

<DOWN> 

scrolls through the menu options in descending order, or decreases a numeric value 

<ENTER> 

used to select and store the current menu or option within the menu 

 

 

The control panel display shows the menu items you select from the menu map. When a menu function is 
selected, the display will show immediately the first available option for the selected menu function. To 
select a menu item, press <ENTER>. 

 

Use the <UP> and <DOWN> buttons to navigate the menu map and menu options. Press <ENTER> to 
access the menu function currently displayed or to enable a menu option. To return to the previous option 
or menu without changing the value, press the <MENU> button. 

7.3

 

The Fluid Sensor 

This device is equipped with a fluid sensor to protect the pump. The sensor tests whether there is fluid inside 
the supply pipe. If not, the device shuts off the pump after 20 s and the display starts flashing. 
In this case, switch off the device and refill the reservoir with smoke liquid. 
If the display keeps flashing after you refill the reservoir, you need to reset the fluid sensor. Proceed as follows: 

 

Switch off the device, then switch it on again. 

 

Or, from DMX operating mode: set channel 1 to off (DMX value 0–9), then set to on (DMX value 10 or 
higher). 

 

 

Caution

: We strongly recommend that you 

keep the fluid sensor enabled

 at all times. If not, the 

device may be permanently damaged if it works without fluid. Note that this damage is not covered 
by the warranty. 

 

To check if the fluid sensor is enabled, proceed as follows: 

1.

 

Press <MENU> until <oiL> is displayed and press <ENTER> to confirm. 

2.

 

If the display shows <off>, use <UP> or <DOWN> to select <on>. 

3.

 

Press <ENTER> to confirm. 

The fluid sensor is now enabled and the pump is protected. 

7.4

 

LED Colour Selection 

In stand-alone mode, the LEDs light up while the device produces smoke. You can choose the colour of the LED 
beam in the settings menu. 

Note

: In DMX mode, the LEDs are controlled via DMX signals. See the DMX values table further in this manual 

for an overview of all the possibilities. 
To choose the colour of the LED beam for stand-alone mode, proceed as follows: 

1.

 

Press <MENU> until <Colo> is displayed and press <ENTER> to confirm. 

2.

 

Use <UP> or <DOWN> to select the desired colour: 

o

 

<OFF>: to switch the LEDs off. The LEDs do not light up while the device produces smoke. 

o

 

<Co1>–<Co9>: to select one of the predefined colours (red, green, blue, pink…). 

o

 

<rand>: to choose a randomly changing colour. The LEDs change colour every second while the device 
produces smoke. 

3.

 

Press <ENTER> to confirm. 

7.5

 

Operation With Remote Control 

To use the device with the remote control, wait until the device has heated up, and then press the button on 
the remote control. The LEDs light up in the selected colour and the device produces smoke during 5 seconds. 
The LEDs go out when the machine stops producing smoke. 

Summary of Contents for LX502

Page 1: ...LX502 LED PYRO 1500W FOGGER USER MANUAL...

Page 2: ...LX502 V 02 31 10 2013 2 Velleman nv A B C...

Page 3: ...LX502 V 02 31 10 2013 3 Velleman nv D E F...

Page 4: ...ualified person carry out the electric connection Disconnect the device from the mains to clean it to fill the reservoir or when it is not in use Handle the power cord by the plug only This device is...

Page 5: ...ice against damage by leaving it switched off until it has reached room temperature This device is designed for professional use on stage in discos theatres etc The device shall only be used indoors w...

Page 6: ...Turn the device upside down again and place the reservoir back in the device 6 Place the bracket over the reservoir and screw it down F 6 3 Preparation 1 Unscrew the cap 2 of the reservoir 1 2 Pour h...

Page 7: ...with smoke liquid If the display keeps flashing after you refill the reservoir you need to reset the fluid sensor Proceed as follows Switch off the device then switch it on again Or from DMX operating...

Page 8: ...0 255 Red dimmer 100 0 3 0 9 Green LEDs off 10 255 Green dimmer 100 0 4 0 9 Blue LEDs off 10 255 Blue dimmer 100 0 5 0 9 Changing colours off 10 255 Changing colours 6 0 9 Changing colour speed off 10...

Page 9: ...liquids not incl standard smoke liquid order code VDLSL5 5 L high density smoke liquid order code VDLSLH5 5 L pro high density smoke liquid order code VDLSLHT5 5 L cleaning liquid order code VDLCL Us...

Page 10: ...shocks falls dust dirt humidity and by the article as well as its contents e g data loss compensation for loss of profits consumable goods parts or accessories that are subject to an aging process du...

Reviews: