Luxibel LX305 User Manual Download Page 6

 

LX305 

V. 02 – 22/05/2014 

©Velleman nv 

M&S Mode 

Master 

 

Selects Master mode 

Slave 

 

Selects Slave mode 

Temp xx° C 

 

 

Displays product’s internal temperature 

 

Power Linking 

The LX305 supports power linking. You can power up to 21 devices at 230 V. Never exceed this number. 

Power linking cords can be purchased separately. 

DMX Linking 

You can link the device to any DMX controller with a standard DMX serial connection. If you use another 

DMX compatible product with the LX305, you can control each device with a single DMX controller. 
 

7.2

 

Stand-Alone Mode 

In stand-alone mode, the device runs one of the built-in programs. 
To set the device to stand-alone mode: 
1.

 

Unplug any connection from the DMX input of the device. 

2.

 

Press MENU until <Auto> is displayed and press ENTER. 

3.

 

Use UP and DOWN to select the built-in program and press ENTER. 

7.3

 

Master/Slave Mode 

The master/slave mode allows for connecting several devices to a single master device in a daisy chain. 

All slave devices will then work synchronously with the master device. The first device in the daisy chain 

functions as the master device. 
To set the devices to master/slave mode: 
1.

 

Unplug any connection from the DMX input of the master device (the first device in the chain). 

2.

 

Connect the DMX input of the first slave device to the DMX output of the master device. 

3.

 

Connect the DMX input of the subsequent slave devices to the DMX output of the previous slave 

device. 

Master 
1.

 

Set up the unit as described in the section Stand-Alone Mode above. 

2.

 

Press MENU until <M&S Mode> is displayed and press ENTER. 

3.

 

Use UP and DOWN to select <Master> and press ENTER. 

Slave 
1.

 

On each slave device, press MENU until <M&S Mode> is displayed and press ENTER. 

2.

 

Use UP and DOWN to select <Slave> and press ENTER. 

7.4

 

DMX Mode 

The DMX mode allows you to control the device with any universal DMX controller. 

 

All DMX-controlled devices need a digital start address so that the correct device responds to the 

signals. This digital start address is the channel number from which the device starts to "listen” to 

the DMX controller. The same starting address can be used for a whole group of devices or an 

individual address can be set for every device. 

 

When all devices have the same address, all the units will listen to the control signal on one 

particular channel. In other words: changing the settings of one channel will affect all devices 

simultaneously. If you set individual addresses, each device will listen to a separate channel number. 

Changing the settings of one channel will only affect the device in question. 

To set the device to work with a DMX controller: 
1.

 

Press MENU until <Channel> is displayed and press ENTER. 

2.

 

Use UP and DOWN to select a channel and press ENTER. 

3.

 

Press MENU until <Address> is displayed and press ENTER. 

4.

 

Use <UP> and <DOWN> to set the DMX start address and press ENTER. 

 

Start addresses 
Use the table below to define the correct address. The table shows the settings for units 1 to 3. Apply the 

same principle for the other units. 

 

Summary of Contents for LX305

Page 1: ...LX305 Nuxiled 1000 DMX controlled LED strobe USER MANUAL...

Page 2: ...imilarly qualified persons in order to avoid any hazard Make sure that the available voltage does not exceed the voltage stated in the specifications of this manual This device falls under protection...

Page 3: ...ing defects or problems Mechanical wear and LEDs are not covered by warranty A qualified technician shall install and service this device Do not switch the device on immediately after it has been expo...

Page 4: ...e weight of the device Make sure that the maximum height of drop is limited so that no injuries can occur If the safety cables are long wrap them around the truss multiple times to reduce the height o...

Page 5: ...nts corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 resistor between pins 2 and 3 which is then plugged into the XLR output socket of t...

Page 6: ...f the previous slave device Master 1 Set up the unit as described in the section Stand Alone Mode above 2 Press MENU until M S Mode is displayed and press ENTER 3 Use UP and DOWN to select Master and...

Page 7: ...e channel function value percent setting 1 Flash intensity 000 005 006 255 Black out Minimum to maximum 2 Flash duration 000 255 Flash duration 15 990ms 3 Flash rate 000 005 006 255 No flash 1Hz 30Hz...

Page 8: ...us blinder effect 5 Segment 5 000 005 006 249 250 255 Blackout Flash rate slow to fast Continuous blinder effect 6 Segment 6 000 005 006 249 250 255 Blackout Flash rate slow to fast Continuous blinder...

Page 9: ...60 161 190 191 220 221 255 No function Auto Program 0 Auto Program 1 Auto Program 2 Auto Program 3 Auto Program 4 Auto Program 5 Auto Program 6 Auto Program 7 10 Auto speed 000 255 Auto speed slow to...

Page 10: ...ower supply 100 240 V 50 60 Hz PowerCon in and out power consumption 190 W LED source 324 x 0 5 W SMD 6500 K colour temperature 6500 K beam angle 120 DMX in and output 3 and 5 pin XLR dimensions 230 x...

Page 11: ...article e g by oxidation shocks falls dust dirt humidity and by the article as well as its contents e g data loss compensation for loss of profits o consumable goods parts or accessories that are sub...

Reviews: