Cleaning
•
Clean the external optics with a soft cloth.
•
Always be sure to dry all parts completely before plugging the unit back
in.
•
Cleaning frequency depends on the environment in which the unit
operates (i.e. smoke, fog residue, dust, dew).
•
Do not immerse the device in any liquid.
Maintenance
•
All screws should be tightened and free of corrosion.
•
The housing, the lenses, the mounting supports and the installation
location (e.g. ceiling, suspension, trussing) should not be deformed,
modified or tampered with; e.g. do not drill extra holes in mounting
supports, do not change the location of the connections…
•
Mechanically moving parts must not show any signs of wear and tear.
•
The electric power supply cables must not show any damage. Have a
qualified technician maintain the device.
•
There are no user-serviceable parts, apart from the fuse.
•
Refer to an authorized dealer for service and/or spare parts.
11.
Technical Specifications
power supply
230 Vac 50 Hz
power consumption
56 W
light source
5050 smd LEDs 50 000 h
refresh rate
400 Hz
pitch
25 mm
dimensions
1000 x 108 x 140 mm
weight
4.5 kg
Use this device with original accessories only. Velleman nv cannot
be held responsible in the event of damage or injury resulting from
(incorrect) use of this device.
For more info concerning this product and the latest version of this
manual, please visit our website www.luxibel.com.
The information in this manual is subject to change without prior
notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All
worldwide rights reserved. No part of this manual may be copied,
reproduced, translated or reduced to any electronic medium or otherwise
without the prior written consent of the copyright holder.