3.

 

General Guidelines 

Refer to the 

Velleman® Service and Quality Warranty 

on the last pages of this manual. 

 

 

Keep this device away from dust and extreme temperatures. Make sure the ventilation 
openings are clear at all times. For sufficient air circulation, leave at least 1" (± 2.5 cm) 
in front of the openings. 

 

Protect this device from shocks and abuse. Avoid brute force when operating the 
device. 

 

 

Familiarise yourself with the functions of the device before actually using it. Do not allow operation 

by unqualified people. Any damage that may occur will most probably be due to unprofessional use 
of the device. 

 

All modifications of the device are forbidden for safety reasons. Damage caused by user modifications 
to the device is not covered by the warranty. 

 

Only use the device for its intended purpose. All other uses may lead to short circuits, burns, 

electroshocks, lamp explosion, crash, etc. Using the device in an unauthorised way will void the 
warranty. 

 

Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and 
the dealer will not accept responsibility for any ensuing defects or problems. 

 

Mechanical wear and LEDs are not covered by warranty. 

 

A qualified technician should install and service this device. 

 

Do not switch the device on immediately after it has been exposed to changes in temperature. 
Protect the device against damage by leaving it switched off until it has reached room temperature. 

 

This device is designed for professional use on stage, in discos, theatres, etc. The device should only 
be used indoors with an alternating current of 240 VAC, 50 Hz. 

 

Lighting effects are not designed for permanent operation: regular operation breaks will prolong their 
lives. 

 

Use the original packaging if the device is to be transported. 

 

Keep this manual for future reference. 

4.

 

Features 

The PIXMOVE 6 is a newly designed motorized linear LED luminaire in the Prolights range. It is conceived 
to achieve high-brightness and versatility. The LX116 has 6 x 8 W RGBW LEDs that can be controlled in 
pixel-to-pixel mode, with 250° motorized tilt inclination through DMX. Several pre-programmed dynamic 
effects are available in the internal memory, which can be combined with multiple reproduction methods 
and colour macros. This PIXMOVE 6 is perfect for architectural constructions on stage. 

 

 

12 x 8 W RGB high-power LEDs 

 

motorized tilt axis with rotation to 250° 

 

auto mode with presets for automatic programmes with speed control 

 

master/slave mode for stand-alone operations 

 

DMX controlled from basis to advanced modes  

o

 

6-channel mode: RGBW, tilt, tilt speed 

o

 

8-channel mode: RGBW, dimmer, shutter, tilt, tilt speed 

o

 

10-channel mode: RGBW, shutter, macro, auto, auto speed, dimmer, tilt, tilt speed 

o

 

26-channel mode: RGBW for each pixel, tilt, tilt speed 

 

colour temperature presets from 3200 K to 10000 K 

 

static reproduction of a colour via stand-alone mode 

 

flicker-free (400 Hz) 

 

power and signal link via powerCON and 3-pin XLR  

Summary of Contents for LX116

Page 1: ...LX116 PIXMOVE 12 12 X 8 W RGBW LED WITH TILT MOVEMENT USER MANUAL...

Page 2: ...LX116 V 02 22 10 2014 2 Velleman nv terminator How to turn the controller line from 3 pins into 5 pins plug and socket...

Page 3: ...r use only Keep this device away from rain moisture splashing and dripping liquids Never put objects filled with liquids on top of or close to the device Keep this device away from children and unauth...

Page 4: ...ice against damage by leaving it switched off until it has reached room temperature This device is designed for professional use on stage in discos theatres etc The device should only be used indoors...

Page 5: ...n the bracket screws Make sure there is no flammable material within a 0 5 m radius of the device Have a qualified electrician carry out the electric connection Connect the device to the mains with th...

Page 6: ...options in descending order decrease value Menu menu submenu 1 submenu 2 description Auto Auto 1 Speed T Speed 100 Auto programme selection with programme speed and motor speed setting Auto 2 Auto12...

Page 7: ...press ENTER to confirm 6 Repeat these steps for all slave units Master unit 1 Connect the master device to the mains to switch it on 2 Set the master unit to work in one of the running modes 3 Connect...

Page 8: ...slow 8 channel mode channel from to function description 1 000 255 red from 0 100 2 000 255 green from 0 100 3 000 255 blue from 0 100 4 000 255 white from 0 100 5 000 255 dimmer from 0 100 6 000 010...

Page 9: ...enses the mounting supports and the installation location e g ceiling suspension trussing should not be deformed modified or tampered with e g do not drill extra holes in mounting supports do not chan...

Page 10: ...he event of damage or injury resulting from incorrect use of this device For more info concerning this product and the latest version of this manual please visit our website www luxibel com The inform...

Page 11: ...shocks falls dust dirt humidity and by the article as well as its contents e g data loss compensation for loss of profits consumable goods parts or accessories that are subject to an aging process du...

Reviews: