Installation  

  
There are specific regulations like BGV C1 (old VBG 70) or country related regulations which 
need to attend during the installation. The installation has to be handled by skilled persons 
only!   

Suspension device hast to be built and calculated in order to handle up to 10 times its 

specific load limit over a time of one hour without permanent or harmful deformation.  

Installation has to be done with a separate, independent suspension device like a safety 

chain. A second suspension device has to be built in order to assure that in case of error no 
part of an installation can fall off.  

Trespassing the danger zone below the installation during the assembling is prohibited.  

Installer has to take care of all safety and machinery installations are approved by authorized 

persons before first operation or after changes before restarting.  

Installer has to take care of all safety and machinery installations are approved by skilled 

persons at least once a year.  

Installer has to take care of all safety and machinery installations are approved by authorized 

persons every four years during the acceptance inspection. Spotlight should ideally installed 
outside peoples lounge area.  

Attention

 

 

Installation overhead needs a high level of experience. This includes (but is not just limited 

to) calculation and definition of load capacity, used installation material and regular safety 
inspections of used material and the fixture itself. Never try to do the installation by yourself if 
you are not qualified, instead you have to instruct a skilled installer. Inappropriate 
installations can cause injuries and/or damage of property. Spotlight has to be installed 
outside areas where people can touch it.  

Professional truss system or similar licensed suspension systems have to be used if the 

spotlight is used in suspension from ceiling or other constructions. Spotlights can never be 
installed freely suspended!  

Spotlights can cause injuries when fall off. If you are not trained in questions of safety for the 

different kinds of installation do NOT install the spotlight! Assure that the mounting surface 
can hold at least ten times the point load of the spotlight before installing the fixture.  

Assure the specified safety distances to flammable material. 

 

Attach the spotlight with its yoke and the use of a suitable hook/clamp to your truss system. 

The therefor used opening has a diameter of about 12 mm. According to your installation 
also similar but approved suspension devices are possible.  

When installing the spotlight overhead make sure to safe the fixture by a safety chain which 

is specified at least with a load limit of 12 times of the spotlights weight. Only safety chain 
with approved connective can be used. Attach the safety chain to its designated opening and 
attach it to the truss system or a similar and safe attachment point. Assure to close the 
fasteners as specified.  

To adjust the angle of the fixture open the locking screw, set the fixture in its position and 

close it by hand.  

Summary of Contents for B EXPO500TW

Page 1: ...1...

Page 2: ...2 User Manual Table of contents Product introduction 3 Safety Notes 4 Maintenance 7 Installation 8 Control Menu 10 DMX Mode 11 Technical Specifications 13...

Page 3: ...se make sure that the packaging is in good condition and that following items will be found in the box B EXPO500TW fixture 3m DMX cable 1 5m power cable with powercon Safety chain Description of the B...

Page 4: ...to avoid danger Lenses glasses or UV filters must be replaced if they are visually damaged or their effectiveness is impaired e g by broken glass or by deep scratches Ensure that wires never come in...

Page 5: ...wear parts in the device Maintenance and service must be performed only by an authorized service partner Before operate this unit please carefully read this users guide and keep if needed in future I...

Page 6: ...epsy Especially at beam effect extreme caution and observance of these safety instructions is mandatory Don t put or install the device on a surface that subject to vibration or bumps Ta 45 The device...

Page 7: ...temperature from menu Check the fan speed info from menu Replace new LED Set dimmer channel at 255 and strobe channel at 0 5 Replace new power supply Device not response to DMX Faulty communication I...

Page 8: ...of used material and the fixture itself Never try to do the installation by yourself if you are not qualified instead you have to instruct a skilled installer Inappropriate installations can cause inj...

Page 9: ...eways like left picture The mounting place must be sufficient stable and be able to support a weight of 10 times of the unit s weight When the fixture is hanged always additionally secure the device w...

Page 10: ...Information Lamp Temp Fan Speed FAN1 XXXR FAN2 XXXR FAN3 XXXR Soft version Settings Fixture Set Temper C F Fahrenheit Celsius Celsius Fans Mode Auto Silent High Backlight 01 300s 10s Flip Display ON O...

Page 11: ...e mode at standard 18 channels mode and there are several models need to be independently controlled we just simply address first fixture at 1 and second fixture at 21 third one at 41 etc If the devic...

Page 12: ...sistance please just contact authorized dealers Hibernation the device will enter sleeping mode if activated after a period of disconnecting DMX signal to save the power consumption and will return im...

Page 13: ...3 9 x 38 6 cm 20 1 x 17 32 x 15 16 Net weight 11 kg 24 3 lbs Gross weight 12 kg 26 5 lbs Mounting options Hanging 3x M12 hole Standing n a 2nd suspension safety wire 1x eye in back of unit to pass car...

Page 14: ...420 lux Light output 55 Lux 5m 708 lux Lux 10m 230 lux Lux 15m 115 lux Photometric data B Expo500TW CW Light output 21 Lux 5m 4720 lux Lux 10m 1200 lux Lux 15m 580 lux Light output 55 Lux 5m 1100 lux...