LX944600
Installation
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
1. A pressure wire connector is provided on metallic enclosures to permit connections of a minimum No. 8
AWG solid copper bonding conductor between any metal equipment, metal enclosures of electrical
equipment, metal water pipe, or conduit within 5 feet (1.5 m) of the unit as needed
to comply with local requirements. Polymeric enclosures are supplied with an internal equipment ground
bar.
2. THIS CONTROL MUST BE FACTORY INSTALLED OR INSTALLED BY A LICENSED ELECTRICIAN
ACCORDING TO STATE, NATIONAL, AND LOCAL ELECTRICAL CODE AND THE INSTRUCTIONS.
3. Use copper conductors only.
4. DANGER - To reduce the risk of injury do not permit children to use this product unless they are closely
supervised at all times.
5. Install to provide drainage of compartment for electrical components.
6. A ground-fault circuit interrupter (GFCI) designated line is to be installed in accordance with the National
Electrical Code, the Canadian Electrical Code and all local codes in effect at the time of installation. When
unit is provided with a GFCI, the GFCI must be tested monthly. To conduct the test the unit must be
operating. Push the test button. The unit should stop operating and the reset button should appear.
Push the reset button. The unit should now operate normally. If the interrupter fails to operate in this
manner, there is a ground current flowing, indicating the possibility of electric shock. Disconnect the power
until the fault has been corrected.
7. The electrical supply for this product must include a suitably rated switch or circuit breaker to open all
ungrounded supply conductors to comply with Section 422-20 of the National Electrical Code, ANSI/NFPA
70-1987. The disconnect must be readily accessible to the tub occupant but installed at least 5 feet (1.5m)
from tub water.
8. No electrical appliance may be placed within a 5 foot reach path from the water’s edge.
9. Use only non-conductive tubing to connect any air actuator.
10. Valve must be inaccessible to tub occupant and installed at least 5 feet away from the inside walls of
the tub.
READ AND SAVE THESE INSTRUCTIONS