Luxair LA-60-Curva Installation, Maintenance And Usage Download Page 8

 

 

Use 

The hood is designed to be used either for exhausting or filter version. 
The models with no suction motor only operate in ducting mode, and must be connected to an external suction device (not supplied). 
The connecting instructions are supplied with the peripheral suction unit. 

 

 

Ducting version

 

In this case the fumes are conveyed outside of the building by means of a special pipe connected with the connection ring located on 
top of the hood. 

Attention!

 The exhausting pipe is not supplied and must be purchased apart. 

Diameter of the exhausting pipe must be equal to that of the connection ring. 
In the horizontal runs the exhausting pipe must be slightly slanted (about 10°) and directed upwards to vent the air easily from the 
room to the outside. 

Attention!

 If the hood is supplied with active charcoal filter, then it must be removed. 

Connect the hood and discharge holes on the walls with a diameter equivalent to the air outlet (connection flange). 
Using the tubes and discharge holes on walls with smaller dimensions will cause a diminution of the suction performance and a 
drastic increase in noise. 
Any responsibility in the matter is therefore declined. 

!

 

Use a duct of the minimum indispensible length. 

!

 

Use a duct with as few elbows as possible (maximum elbow angle: 90°). 

!

 

Avoid drastic changes in the duct cross-section. 

!

 

Use a duct with an as smooth as possible inside. 

!

 

The duct must be made of certified material. 

 

 

Filter version

 

One active charcoal filter is needed for this and can be obtained from your usual retailer. 
The filter removes the grease and smells from the extracted air before sending it back into the room through the upper outlet grid. 

Installation 

The minimum distance between the supporting surface for the cooking equipment on the hob and the lowest part of the range hood 
must be not less than 65cm from electric cookers and gas or mixed cookers. 
If the instructions for installation for the gas hob specify a greater distance, this must be adhered to. 

 

     

Electrical connection

 

The  mains  power  supply  must  correspond  to  the  rating  indicated  on  the  plate  situated  inside  the  hood.  If  provided  with  a  plug 
connect the hood to a socket in compliance with current regulations and positioned in an accessible area, after installation. If it not 
fitted with a plug (direct mains connection) or if the plug is not located in an accessible area, after installation,   apply a double pole 
switch in accordance with standards which assures the complete disconnection of the mains under conditions relating to over-current 
category III, in accordance with installation instructions. 

Warning!

 Before re-connecting the hood circuit to the mains supply and checking the efficient function, always check that the mains 

cable is correctly assembled. 
The hood is provided with a special power cable ; if the cable is damaged, request a new one from Technical Service. 

 

Mounting 

Expansion wall plugs are provided to secure the hood to most types of walls/ceilings. However, a qualified technician must verify 
suitability of the materials in accordance with the type of wall/ceiling. The wall/ceiling must be strong enough to take the weight of the 
hood. Do not tile, grout or silicone this appliance to the wall. Surface mounting only. 

 

Grease filter 

 

Traps cooking grease particles. 

This must be cleaned once a month (or when the filter saturation indication system – if envisaged on the model in possession – 
indicates  this  necessity)    using  non  aggressive  detergents,  either  by  hand  or  in  the  dishwasher,  which  must  be  set  to  a  low 
temperature and a short cycle. 
When washed in a dishwasher, the grease filter may discolour slightly, but this does not affect its filtering capacity. 
To remove the grease filter, pull the spring release handle. 

 
 

Summary of Contents for LA-60-Curva

Page 1: ...INSTALLATION MAINTENANCE AND USAGE 5 YEARS PARTS 2 YEARS LABOUR WARRANTY Register Now For LA 60 90 Curva...

Page 2: ......

Page 3: ......

Page 4: ...HOOD MUST BE INSTALLED ON MINIMUM 5 125mm ROUND DUCTING OR RECTANGULAR EQUIVALENT...

Page 5: ......

Page 6: ......

Page 7: ...g system for this appliance must not be connected to any existing ventilation system which is being used for any other purpose such as discharging exhaust fumes from appliances burning gas or other fu...

Page 8: ...d the lowest part of the range hood must be not less than 65cm from electric cookers and gas or mixed cookers If the instructions for installation for the gas hob specify a greater distance this must...

Page 9: ...ing point Speed 2 15 minutes 2 fixed flashing point Speed 3 10 minutes 3 fixed flashing point Speed 4 5 minutes 4 fixed flashing point During time running if key 1 or 4 is pressed the hood turns off i...

Page 10: ...model in possession indicates this necessity using non aggressive detergents either by hand or in the dishwasher which must be set to a low temperature and a short cycle When washed in a dishwasher t...

Page 11: ...t also be returned to Luxair within 31days s t c u d o r p r u o n o y t n a r r a w d e d n e t x e e h t e v i e c e r o t r e d r o n i n o i t a l l a t s n i r e t f A Once we receive your Warran...

Page 12: ...RS LABOUR WARRANTY YEARS Luxair UK Limited Luxair House Unit 4 5 Barker Business Park Melmerby Ripon HG4 5NB Telephone 01765 641888 Fax 01765 641889 Email info luxairhoods com www luxairhoods com Foll...