LUX 301 321 Original Instructions Manual Download Page 9

9

Remaining risks

There will still be residual risks even when the device 
is used according to the instructions and under 
observation of all of the safety notes in this set of 
operating instructions:

• Touching the tool in the uncovered section.
• Reaching into the operating tool.
• Kickback from work pieces and work piece 

parts.

Personal protective clothing

Your device at a glance

 P. 3, item 1

1.

Stroke regulator

2.

Locking screw for cutting angle

3.

Switch for pendulum stroke

4.

Saw blade

5.

Foot plate

6.

Dust protection

7.

LED

 P. 4, item 2

8.

On/Off switch

9.

Locking button for permanent operation

10. Switch for blower
11. Locking screw for parallel stopper
12. Storage compartment for saw blade
13. Opening for extraction strut

Scope of delivery

• Jig-saw
• Saw blade
• Parallel stopper
• Extraction strut
• Operating instructions

Using for the first time

Fitting the saw blade

 P. 4, item 3

Suitable saw blades: 

 P. 5, item 4, 

 Technical 

data – p. 11.

– Pull the locking sleeve (14) backwards and hold.
– Place the saw blade (4) as far as it will go into the 

holder.

– Release the locking sleeve (14).
– Ensure that the blade is securely fitted into 

place.

Affixing the extraction strut

 P. 5, item 5

– Fit the extraction strut (15) into the opening (13) 

as shown.

Operation

Check before switching on!

Check to make sure the unit is in a safe operating 
condition:

– Check to make sure there are no visible defects.
– Check to make sure all unit components are cor-

rectly mounted.

Switching on and off

– Switching on: Press the On/Off button (8).
– Switching off: Release the On/Off switch.
– Permanent operation: Press the locking button 

with the On/Off switch (9) held down.

– Set the required stroke rate with the rotating reg-

ulator (1).

Wear goggles when working with the de-
vice.

Wear ear defenders when working with the 
device.

When working with tools that cause con-
siderable dust, wear a dust protection 
mask.

Do 

not

 wear protective gloves when work-

ing with the device.

Wear tight fitting clothes when working 
with the device.

If you have long hair, cover or wear a hair 
net.

WARNING! Risk of death through elec-
tric shock! 

The use of this variant outside 

Switzerland is not permissible for safety 
reasons, as this poses a risk of electric 
shock or fire.
The variant of the product sold in Switzer-
land may only be used in Switzerland, as it 
is equipped with a Swiss plug.
You can identify the variant by means of the 
item number on the product (the instruc-
tions always contain 

all

 item numbers):

Item number Switzerland: 381 124
Item number in other EU countries: 398 094, 
301 321

DANGER! Risk of injury! 

Pull out the 

power plug before conducting any mainte-
nance work on the device.
Shortly after sawing, the saw blade may be 
very hot. Risk of burning! Allow a hot blade 
to cool down. Never clean a hot saw blade 
with flammable liquids.
Even a saw blade which is at a standstill 
can still cut! Always wear gloves when 
replacing the saw blade.

GB

Stichsaege_381124_398094_301321.book  Seite 9  Mittwoch, 16. September 2015  2:19 14

Summary of Contents for 301 321

Page 1: ...STS 750 381124 398094 301321 GB Jig saw GR Stichsaege_381124_398094_301321 book Seite 1 Mittwoch 16 September 2015 2 19 14...

Page 2: ...2 GB Original instructions 6 GR 12 Stichsaege_381124_398094_301321 book Seite 2 Mittwoch 16 September 2015 2 19 14...

Page 3: ...3 1 2 3 4 5 7 6 1 Stichsaege_381124_398094_301321 book Seite 3 Mittwoch 16 September 2015 2 19 14...

Page 4: ...4 8 9 10 11 12 13 2 4 14 3 Stichsaege_381124_398094_301321 book Seite 4 Mittwoch 16 September 2015 2 19 14...

Page 5: ...5 4 15 13 5 16 11 6 Stichsaege_381124_398094_301321 book Seite 5 Mittwoch 16 September 2015 2 19 14...

Page 6: ...s will reduce risk of electric shock Avoid body contact with earthed or grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of elec tric shock if your body is...

Page 7: ...entical replace ment parts This will ensure that the safety of the power tool is maintained General Power Saw Safety Warnings Keep hands away from cutting area and the blade If both hands are holding...

Page 8: ...able liq uids There is a risk of fire and explosion Keep the handles dry and free of grease Slippery handles can lead to accidents Always comply with the all applicable domes tic and international saf...

Page 9: ...ake sure all unit components are cor rectly mounted Switching on and off Switching on Press the On Off button 8 Switching off Release the On Off switch Permanent operation Press the locking button wit...

Page 10: ...f you saw too slowly the plastic will heat up become soft and adhere to the teeth of the blade The cut will be untidy and you will need to clean the blade Things to note when sawing metal When sawing...

Page 11: ...his information is designed to help the user to better assess the dangers and risks The specified vibration emission value was measured in accordance with a normed test procedure and can be used in or...

Page 12: ...12 12 12 16 16 16 17 18 18 18 GR Stichsaege_381124_398094_301321 book Seite 12 Mittwoch 16 September 2015 2 19 14...

Page 13: ...13 GR Stichsaege_381124_398094_301321 book Seite 13 Mittwoch 16 September 2015 2 19 14...

Page 14: ...14 GR Stichsaege_381124_398094_301321 book Seite 14 Mittwoch 16 September 2015 2 19 14...

Page 15: ...15 LED 2 LED GR Stichsaege_381124_398094_301321 book Seite 15 Mittwoch 16 September 2015 2 19 14...

Page 16: ...5 6 7 LED P 4 2 8 ON OFF 9 10 11 12 13 P 4 3 P 5 4 18 14 4 14 P 5 5 15 13 ON OFF 8 ON OFF ON OFF 9 1 45 2 5 2 381124 398094 301321 GR Stichsaege_381124_398094_301321 book Seite 16 Mittwoch 16 Septemb...

Page 17: ...17 5 0 1 3 P 5 6 16 11 10 10 U GR Stichsaege_381124_398094_301321 book Seite 17 Mittwoch 16 September 2015 2 19 14...

Page 18: ...21 230 V 50 Hz 750 W 800 3000 min 1 II 85 mm 8 mm LWA 101 dB A K 3 dB A LPA 90 dB A K 3 dB A 23 68 m s K 1 5 m s P 5 4 381124 398094 301321 GR Stichsaege_381124_398094_301321 book Seite 18 Mittwoch 16...

Page 19: ...theless if you have cause for dissatisfaction please bring the item together with the proof of purchase to the store from which you bought it For our products legal claims for defects are valid from t...

Page 20: ...V 160915 Emil Lux GmbH Co KG Emil Lux Stra e 1 42929 Wermelskirchen GERMANY Stichsaege_381124_398094_301321 book Seite 20 Mittwoch 16 September 2015 2 19 14...