ADVANCED SETTINGS - SYSTEM CONFIGURATION
!
IMPORTANT: By inadvertently modifying system configuration settings, you may seriously
degrade HVAC system performance.
>>
Choose system heating and cooling equipment - remember all you need to do is toggle the
appropriate button until the correct setting appears.
•
Choose
HEAT PUMP
or
2 STAGE HEAT PUMP
or
AIR CONDITIONING
or
NO COMPRESSOR
-
please review the wiring table and diagram for wiring instructions.
•
Choose
FURNACE OFF
(No Furnace) or
ELECTRIC FURNACE
or
EMERGENCY ELECTRICAL
FURNACE
(additional electric furnace which will come on in emergency mode in conjunction
with electric furnace) or
GAS FURNACE
or
OIL FURNACE
or
2 STAGE GAS FURNACE
; please
review the wiring table and diagram for wiring instructions.
• CYCLE RATE
: Set Maximum compressor cycles per hour. We recommend that the factory default
be maintained for optimal performance..
• AUTO CHANGE
: Set the minimum difference between Auto Mode, Heat and Cool temperature set-
points. We recommend that the factory default be maintained for optimal performance.