2

Heating Systems

G

Y

W RH

B

O

RC

Tape Off *

  * If replacing a Honeywell TM-11,
     tape off wire “R”; connect wire “B”
     to terminal “RH.”
** If replacing a Honeywell thermostat
     with a clock wire “C,” tape off wire “C”

G

5

4

B

RC

V

R*

H

W

F

R

H

Tape Off **

C

Tape Off

TC

FAN RELAY

          COOLING COMPRESSOR

                   HEATING CONTROL

                             HEATING TRANSFORMER

                                        DAMPER OR CHANGEOVER VALVE

                                                

(POWERED IN HEAT)

                                                DAMPER OR CHANGEOVER VALVE
                                        

                   

(POWERED IN COOL)

                                                           COOL TRANSFORMER

Cooling Systems

G

Y

W RH

B

O

RC

Y

V

R

C

RC

G

F

TC

Tape Off

FAN RELAY

          COOLING COMPRESSOR

                   HEATING CONTROL

                             HEATING TRANSFORMER

                                        DAMPER OR CHANGEOVER VALVE

                                                

(POWERED IN HEAT)

                                                DAMPER OR CHANGEOVER VALVE
                                        

                   

(POWERED IN COOL)

                                                           COOL TRANSFORMER

* If both Y and C wire are 

present, tape  off  “C” wire.

*

Heating/Cooling Systems

4- or 5-Wire with One Transformer

G

Y

W RH

B

O

RC

C

Y

G

F

W

V

R

RC

B

O

(Optional)

(Optional)

Tape Off

TC

FAN RELAY

          COOLING COMPRESSOR

                   HEATING CONTROL

                             HEATING TRANSFORMER

                                        DAMPER OR CHANGEOVER VALVE

                                                

(POWERED IN HEAT)

                                                DAMPER OR CHANGEOVER VALVE
                                        

                   

(POWERED IN COOL)

                                                           COOL TRANSFORMER

* If both Y and C wire are 

present, tape off “C” wire.

*

FAN RELAY

          COOLING COMPRESSOR

                   HEATING CONTROL

                             HEATING TRANSFORMER

                                        DAMPER OR CHANGEOVER VALVE

                                                

(POWERED IN HEAT)

                                                DAMPER OR CHANGEOVER VALVE
                                        

                   

(POWERED IN COOL)

                                                           COOL TRANSFORMER

Heating/Cooling Systems

5- or 6-Wire with Two Transformers

G

Y

W RH

B

O

RC

Y

C

G

F

W

4

A

RH

B

O

(Optional)

(Optional)

V

R

R

C

Tape Off

TC

*

* If both Y and C wire are 

present, tape off “C” wire.

WIRING DIAGRAMS

Summary of Contents for LUXPRO PSM40SA

Page 1: ... Do not install until all construction work and painting have been completed 2 TOOLS REQUIRED Wirestripper or knife drill with 3 16 bit screwdriver level and a pencil 3 REMOVING OLD THERMOSTAT Please read all instructions carefully As you complete each step check the adjoining square Disconnect electricity and turn off gas to the heater Remove cover from old thermostat Disconnect wires from thermo...

Page 2: ...R VALVE POWERED IN COOL COOL TRANSFORMER If both Y and C wire are present tape off C wire Heating Cooling Systems 4 or 5 Wire with One Transformer G Y W RH B O RC C Y G F W V R R C B O Optional Optional Tape Off TC FAN RELAY COOLING COMPRESSOR HEATING CONTROL HEATING TRANSFORMER DAMPER OR CHANGEOVER VALVE POWERED IN HEAT DAMPER OR CHANGEOVER VALVE POWERED IN COOL COOL TRANSFORMER If both Y and C w...

Page 3: ...N 24 VAC HEAT TRANSFORMER G Y W RH RC O B TYPICAL HOOKUP FOR 3 WIRE HEAT SYSTEM IF THIRD WIRE IS FAN WIRE Figure 9 GAS VALVE 110 FAN 24 VAC TRANSFORMER G Y W RH RC O B TYPICAL HOOKUP FOR 2 WIRE 24V HEATING SYSTEM AND MILLIVOLT SYSTEM Figure 8 GAS VALVE 110 24 VAC TRANSFORMER OR THERMOPILE G Y W RH RC O B These diagrams below are provided for new installations or unreferenced wires N O T E If you h...

Page 4: ...ur convenience Place Base Figure 3 over Sub Base and attach by tightening three captive screws Fasten loosely to wall using two mounting screws Place a level against the bottom of the Base adjust until it is level and then tighten mounting screws to secure Find anticipator setting on old thermostat Setting on new thermostat should be the same Do this by carefully sliding the long pointer Figure 2 ...