![LUX LUMEN StarGuide Maxi Manual Download Page 16](http://html1.mh-extra.com/html/lux-lumen/starguide-maxi/starguide-maxi_manual_1951400016.webp)
StarGuide Maxi
LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM
p.16/24
350 mA
T: +32 3 293 35 50
–
www.lux-lumen.com
STEP 2:
Start the installation at the last unit in the series, by connecting the black
cable on the unit
, with the black ‘loop
-
back cable’ by using
a
Scotchlok™
connector.
Please note: This is the only place, where a black cable is connected with
another black cable.
Insert the trimmed wire ends into the Scotchlok
™
connector. Do not strip
the wires. Make sure all wires are inserted fully to the end of the tunnels,
past the metal connector element.
Take a pliers, and put the Scotchlok
™
connector between the jaws.
Make sure the two wires remain fully inserted in the connector.
Squeeze the handles of the pliers as far as the red cap getting flush with the
rim of the connector body.
You will notice the gel, which is located
in the red cap, being injected in the
cable insertions.
After verifying that the cable is still in
good position, you can put the
Scotchlok™
connector in the tube.