Control
System setup
35
© Lutz-Jesco GmbH 2014
Subject to technical changes.
140327
Solenoid-Diaphragm Dosing Pump
MAGDOS LP
Operating Instructions
BA-10231-02-V03
You can choose from the following options:
Not active
(factory default setting),
Alarm = contact
(issues an alarm when the float contact is
closed),
Alarm = open
(issues an alarm when the float contact is open;
setting for standard Lutz-Jesco GmbH level monitoring systems).
2.
Use the
or
key to choose the desired function and press
OK
.
"Level input" is set.
10.6.6.1 "Level input" configuration
10.6.7 Set "Diaphragm rupture" menu item
As an option, the MAGDOS LP dosing pump is supplied with a leak
sensor in the diaphragm flange; in the case of a diaphragm rupture, the
sensor passes on a signal to the dosing pump and stops it.
For more information, refer to “Diaphragm rupture sensor leak sensor”
on page 21.
For information on the connection, see “Diaphragm rupture input” on
page 30.
1.
Use the
or
key to choose the
Diaphragm rupture
menu
item and press
Setup
.
You can choose from the following options:
Not active
(factory default setting),
Alarm = contact
(issues an alarm if the sensor output is closed
for five strokes; setting for standard Lutz-Jesco GmbH leak sensor),
Alarm = open
(issues an alarm if the sensor output is open for
five strokes).
2.
Use the
or
key to choose the desired function and press
OK
.
"Diaphragm rupture" is set.
10.6.8 Set "Release input" menu item
Option of starting or stopping the dosing pump externally.
For information on the connection, see “Release input” on page 29.
For information on starting and stopping the dosing pump, see “External
On/Off via Release input” on page 48.
1.
Use the
or
key to choose the
Release input
menu item and
press
Setup
.
You can choose from the following options:
Not active
(factory default setting),
Run = contact
(enables the dosing pump if both contacts are
closed),
Run = open
(enables the dosing pump if both contacts are open).
2.
Use the
or
key to choose the desired function and press
OK
.
"Release input" is set.
10.6.9 Set "Dosing control" menu item
The FLOWCON LP 1, which is available as an optional extra, allows you
to monitor the dosing medium's flow motion after a dosing pump stroke.
For instructions on the hydraulic installation, see “FLOWCON LP 1 flow
meter” on page 20.
For information on the connection, see “Dosing control input” on
page 30.
The system displays the selected setting of the level input as
an icon on the start screen of each operating mode. For an
explanation of the icons, see page 32.
Status
Display
Level input
Dosing pump
Alarm =
contact
Alarm =
open
Tank full
Running
Tank at
minimum
(alert)
Running
Tank
empty
(main
alarm)
Stopped
Table 10-9: Level input configuration
i
The system displays the selected setting of the Release input
as an icon on the start screen of each operating mode. For an
explanation of the icons, see page 33.
Please follow the operating instructions for the
FLOWCON LP 1 flow meter. It contains instructions regarding
operation using the MAGDOS LP.
i
i