![Lutron Electronics VB-8206SD Operation Manual Download Page 25](http://html1.mh-extra.com/html/lutron-electronics/vb-8206sd/vb-8206sd_operation-manual_1950961025.webp)
7-4 Set beeper sound ON/OFF
When the lower display show " bEEP "
1)Use the " Button " ( 3-6, Fig. 1 ) or " Button "
▲
▼
( 3-5, Fig. 1 ) to select the upper value to " yES " or
" no ".
yES - Meter's beep sound will be ON with default.
no - Meter's beep sound will be OFF with default.
is power ON.
2)After select the upper text to " yES " or " no ", press the
" Enter Button " ( 3-4, Fig. 1 ) will save the setting
function with default.
function with default.
7-5 Set sampling time ( seconds )
When the lower display show " SP-t "
1)Use the " Button " ( 3-6, Fig. 1 ) or " Button " (
▲
▼
3-5, Fig. 1 ) to adjust the value ( 1, 2, 5, 10, 30,60,
120, 300, 600, 1800,3600 seconds ).
2)After the Sampling value is selected, press the "
Enter Button " ( 3-4, Fig. 1 ) will save the setting
function with default.
7-6 SD memory card Format
When the lower display show " Sd F "
1)Use the " Button " ( 3-6, Fig. 1 ) or " Button " (
▲
▼
3-5, Fig. 1 ) to select the upper value to " yES " or
" no ".
23