4
Sivoia QED
Link:
Class 2/PELV Wiring
connections to EDUs,
Power Panels, or
other Keypads.
Male EDU Connector
Sivoia QED
Keypad Wiring
Installation Instructions
Occupant Copy
4
4. Each Keypad terminal will accept up to two 1.0 mm
2
(#18 AWG) wires.
Connect two 1.0 mm
2
(#18 AWG) wires to terminals 1 and
2 of the Keypad’s terminal block.
Connect two 1.0 mm
2
(#18 AWG) shielded, twisted pair
wires to terminals 3 and 4 of the Keypad’s terminal block.
1
2
3
4
Common
12V
MUX
MUX
AC1
AC2
EGND
Female EDU
Connector
Sivoia QED
EDU
Back of
Sivoia QED
Keypad
Installation
Keypad circuits are classified as Class 2 circuits (U.S.A.) and
PELV circuits (IEC). When installing and wiring to these
Keypads, follow all applicable national and/or local wiring
regulations.
Warning:
Always turn Off the circuit breaker or
remove the main fuse from the power line before
doing any work.
Failure to do so can result in
serious personal injury.
1. Turn power Off to all EDUs and power panels.
2. Mount standard German or UK backboxes (60 mm
measured centre to centre of mounting holes).
3. Strip insulation from wires so that 10 mm. (3/8 in) of bare
wire is exposed for 1.0 mm
2
(#18 AWG) wire.
ON
OFF
ON
OFF
ON
OFF
10 mm (3/8 in.)