background image

Installation Instructions

Please Leave for Occupant

SV-100SF-PI

24 V~ Plug-In Transformer

Input: 120 V~  50/60 Hz  0.93 A Output: 24 V~  50/60 Hz  3.59 A 95 VA Class 2 (PELV)

Please read before installing.

Description

The SV-100SF-PI, see Figure 1, is a 24 V~, Class 2

(PELV) plug-in transformer that is used with a 

Sivoia or

Sivoia QED motorized roller blind. The transformer pro-

vides enough power for one 

Sivoia or Sivoia QED

Electronic Drive Unit to operate a 100 square foot (9.29 m

2

)

shade. (225 square foot (20.9 m

2

) for a high torque Motor

Drive Unit). The transformer is designed to be plugged into

a standard 120 V~ receptacle. The transformer contains a

circuit breaker on the secondary side to protect the device

in the event of a miswire.

Caution - All wiring must be in accordance with

national and local electrical codes.

Caution - Do not short the output AC terminals.

Caution - Ensure that the earth ground is 

connected to the 

Sivoia or Sivoia QED Electronic 

Drive Unit.

Installation

Note: Each transformer can power only 

one Sivoia or

Sivoia QED Electronic Drive Unit.

1. Run Electronic Drive Unit power wiring to the

transformer. Run the low-voltage power and earth

ground wiring from the Electronic Drive Unit to the

screw terminals on the secondary side of the

transformer. See Figure 2.

2. Check that the output AC terminals are not 

shorted.

3. Plug the transformer into a 120 V~ receptacle.

Note: If the Electronic Drive Unit does not power up after

plugging in the transformer, press the circuit breaker

reset button located on the transformer.

Power Wiring Types and Maximum

Lengths

Type

Maximum Length

________________________________________________

3 conductor #16 AWG 

200 ft. (60 m)

3 conductor #18 AWG 

150 ft. (45 m)

3 conductor #20 AWG 

100 ft. (30 m)

3 conductor #22 AWG 

60 ft. (18 m)

Figure 1

Sivoia QED

TM

English

Reviews: