Multi-Location Installation without Neutral

2, 3

Brass

Black

Blue

Green

Ground

Lighting 
Load

Hybrid Keypad or 

Remote Dimmer

Brass

Black

Blue

Green

Ground

Remote Dimmer or 

Hybrid Keypad

120 V

  

50 / 60 Hz

Brass

Black

Blue

Green

Ground

Hot/Live

Neutral

Remote Dimmer or 

Hybrid Keypad

Silver

Multi-Location Installation with Neutral

3, 4

Brass
Silver

Black

Blue

Green

Ground

Brass

Black

Blue

Green

Ground

Remote Dimmer

120 V

  

50 / 60 Hz

Brass

Black

Blue

Green

Ground

Hot/Live

Neutral

Remote Dimmer

Hybrid Keypad

Wiring Diagram 1b

Lighting 
Load

Single Location Installation without Neutral

1, 2

Wiring Diagram 2a

Brass

Black

Blue

1

Green

Ground

Hot/Live

Neutral

Lighting 
Load

Hybrid Keypad

120 V

  

50 / 60 Hz

Silver

Single Location Installation with Neutral

1

Wiring Diagram 1a

120 V

  

50 / 60 Hz

Brass
Silver

Black

Blue

1

Green

Ground

Hot/Live

Neutral

Hybrid Keypad

Lighting 
Load

Load Specifications:

1

  

Load Type: 

Hybrid Keypads are designed for use with permanently installed incandescent, magnetic 

low-voltage, or tungsten halogen only. To reduce the risk of overheating and possible damage to other 
equipment, do not install Hybrid Keypads to control receptacles or motor-operated appliances. 

2

  Low-Voltage Applications:

 Use Hybrid Keypads with magnetic (core and coil) low-voltage transformers 

only. Not for use with electronic (solid-state) low-voltage transformers. Operation of a low-voltage circuit 
with lamps inoperative or removed may result in transformer overheating and premature failure. Lutron 
strongly recommends the following: 

 

•  

Do not operate low-voltage circuits without operative lamps in place.

 

•  

Replace burned-out lamps as quickly as possible.

 

•  

Use transformers that incorporate thermal protection or fused transformer primary windings to 
prevent transformer failure due to overcurrent.

Important Notes

 WARNING -

 

Entrapment hazard - 

To avoid the risk of entrapment, 

serious injury, or death, these controls must not be used to control 

equipment which is not visible from every control location or which 

could create hazardous situations such as entrapment if operated accidentally. 

Examples of such equipment which must not be operated by these controls 

include (but are not limited to) motorized gates, garage doors, industrial doors, 

microwave ovens, heating pads, etc. It is the installer’s responsibility to ensure 

that the equipment being controlled is visible from every control location and 

that only suitable equipment is connected to these controls. Failure to do so 

could result in serious injury or death.

Codes:

 Install in accordance with all local and national electrical codes.

Grounding:

 When no “grounding means” exist in wallbox, the 2011 National 

Electrical Code

R

 (NEC

R

) allows a control to be installed as a replacement if 1) 

a nonmetallic, noncombustible faceplate is used with nonmetallic attachment 

screws or 2) the circuit is protected by a ground fault circuit interrupter (GFCI). 

When installing a control according to these methods, cap or remove green 

wire before screwing control into wallbox.

Neutral Wire:

 Hybrid Keypads have an available neutral wire terminal that can 

be connected to the neutral wire in a wallbox where the Hybrid Keypad is to 

be installed. Connecting the neutral wire to a Hybrid Keypad allows a lower 

minimum load to be used. Also, normal keypad operation will be available even 

if the attached load is not installed or if the lamp is burned out. If a neutral 

wire connection is available, connect it to the silver terminal. If a neutral wire 

connection is desired but not available in the wallbox, contact a licensed 

electrician for installation.

Environment:

 Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 

0% to 90% humidity, non-condensing. Indoor use only.

Spacing:

 If mounting one control above another, leave at least 4 ½ in (114 mm) 

vertical space between them.

Wallplates:

 Lutron

R

 Claro

R

 and Satin Colors

R

 wallplates are strongly 

recommended for best color match and clean aesthetic appearance. Do not 

paint keypads, buttons, or wallplates.

Cleaning:

 To clean, wipe with a clean damp cloth. 

Do NoT

 use any chemical 

cleaning solutions.

Wallboxes: 

Lutron recommends using 3 ½ in (89 mm) deep wallboxes for easier 

installation. Several controls may be installed in one multigang wallbox.

Remote Dimmers:

 Use only Remote Dimmers (RD-RD) with Hybrid Keypads. 

Up to 9 RD-RD controls may be used with a Hybrid keypad. 

RF Device Placement:

 RF dimmers, switches, keypads and shades / draperies 

must be located within 30 ft (9 m) of an RF signal repeater. For systems without 

an RF signal repeater, all RF dimmers, switches, keypads and shades / draperies 

must be located within 30 ft (9 m) of each other. Remote dimmers and switches 

are not required to be within a specific range.

Engraving:

 The Prepaid Engraving Certificate included with the Hybrid 

Keypad can be redeemed for a custom engraved replacement kit. To order a 

replacement kit please follow the instructions at: www.lutron.com/buttons

Load Type

1

Minimum Load

Maximum Load

With Neutral

Without Neutral

Incandescent

15 W

50 W

450 W

MLV

2

15 W / VA

50 W / VA

350 W / 450 VA

Multigang Installations

In multigang installations, several controls are grouped horizontally in one 
multigang wallbox. When combining controls in a wallbox, derating is required; 
however, no derating is required for Remote Dimmers.

Derating Chart 

Load Type

End of Gang

Middle of Gang

Incandescent

350 W

250 W

MLV

250 W / 350 VA

200 W / 250 VA

Installation

            

  WARNING -

 

Shock hazard -

 To avoid the risk of electric shock,

 

locate 

and remove fuse or lock circuit breaker in the OFF position before 
proceeding. Wiring with power ON could result in serious injury or death.

1.

  Turn power OFF at fusebox or circuit breaker.

2.  

Check the installation for short circuits before installing control(s). With power 
OFF, install standard mechanical switch(es) between Hot and load. Restore 
power. If lights do not work or a breaker trips, check wiring. Correct wiring 
and check again. Install control(s) only when short is no longer present. 
Warranty is void if keypad is installed in a shorted circuit.

3.

  Wire keypads according to one of the following options:

a.  

Terminals: 

 

Trim or strip wallbox wires to the length indicated by the strip gauge on the 
back of the keypad.

•  Push-In Terminals: Use with 14 AWG (1.5 mm

2

solid copper wire  

only

. DO NOT use stranded or twisted wire.

Insert wires fully. To release wire, insert small, flat screwdriver into slot  
below push-in terminal. Push screwdriver in while pulling wire out.
 

OR

•  Screw Terminals:

 

use with 12 AWG (2.5 mm

2

) or 14 AWG (1.5 mm

2

)  

solid copper wire only

. DO NOT use stranded or twisted wire. 

Wrap wire around screw terminal. Tighten securely to 5 in-lb (0.55 N•m).

b.  

Wire Connectors: 
Prepare wires. When making wire connections, follow the recommended 
strip lengths and combinations for the supplied wire connector.

Note: Wire connector provided is suitable

 

for copper wire only.

Wire Connector:

•  Strip insulation 3/8 in (10 mm) for 14 AWG (1.5 mm

2

)  

or 12 AWG (2.5 mm

2

) wire

•  Strip insulation 7/16 in (11 mm) for 18 AWG 

 

(0.75 mm

2

) wire

•  Use to join one or two 14 AWG (1.5 mm

2

) or 12 AWG

 

  

(2.5 mm

2

) wires with one 18 AWG (0.75 mm

2

) ground wire.

For installations WITH a neutral wire:

 

See 

Wiring Diagrams 1a

 or 

1b

.

For installations WITHOUT a neutral wire:

 

See 

Wiring Diagram 2a

 or 

2b

.

Note: If a neutral wire connection is available, connect it to the silver terminal.

4.

  Push all wires back into the wallbox and loosely fasten the Hybrid Keypad to the 

wallbox using the control mounting screws provided. Do not pinch the wires.

5.

  Attach Lutron

R

 Claro

R

 or Satin Colors

R

 wallplate adapter and wallplate. See 

the 

Mounting Diagram

.

  a.  Install the wallplate adapter onto the front of the Hybrid Keypad.
  b.  Tighten the keypad mounting screws until wallplate adapter is flush to the 

wall (do not over-tighten).

  c.  Snap the wallplate onto the wallplate adapter and verify that the Hybrid 

Keypad is aligned properly.

  d.  If the Hybrid Keypad is misaligned, remove wallplate and loosen the 

mounting screws to adjust the Hybrid Keypad appropriately. When the Hybrid 
Keypad is alligned properly, snap the wallplate onto the wallplate adapter.

6.

  Restore power. Check for correct local operation. See 

operation

.

Installation Instructions

Please Read Before Installing

1

 

 When using controls in single location installations, tighten the blue terminal without any 

wires attached. DO NOT connect the blue terminal to any other wiring or to ground.

2

  In installations without a neutral wire connection, tighten the silver terminal without any 

wires attached. DO NOT connect the silver terminal to any other wiring or to ground.

3

 

 Up to 9 Remote Dimmers  may be connected to the Hybrid Keypad. Total blue terminal 

wire length may be up to 250 ft (76 m). 

4

  Neutral wire Hybrid Keypads must be connected on the load side of a multi-location 

installation.

operation

Lamp Replacement

 WARNING -

 

Shock hazard -

 For any procedure other than routine lamp 

replacement, power must be disconnected at the main electrical panel. 
Working with power ON could result in serious injury or even death. 

For routine lamp replacement, remove power from the fixture(s) by pulling the 
FASS

T

 switch out on both the Hybrid Keypad and all Remote Dimmers

Troubleshooting Guide

Lutron Elec tron ics Co., Inc. 

7200 Suter Road

Coopersburg, PA 18036-1299
P/N 044-299 Rev. A   10/2011

Symptom

Probable Cause and Action

Lights do not 
respond to a 
Hybrid Keypad 
button press 
or do not go to 
desired levels.

Improper programming

   •  Program according to the system Setup Guide.

If the system is GUI programmed, ensure that the load 
has been assigned to the keypad button in the GUI.
If the system is programmed through walk-around 
programming, ensure that the load has been assigned to 
the keypad button.
Power not present at keypad

   •  Circuit breaker tripped or OFF. Reset or turn ON 

circuit breaker.

The FASS

T

 switch is pulled out.

   •  Push 

FASS

T

 switch in.

Wiring

   •  Wires shorted. Make sure the blue terminal is not 

grounded or shorted to any other wires.

   •   Wiring error. Wire the Hybrid Keypad according to 

the 

Installation

 section and the appropriate 

Wiring 

Diagram

.

Lamps burned out or not installed

   •   Replace or install lamps.

Dioded lamps

   •   If dioded lamps are being used, replace with 

 

non-dioded lamps.

Out of RF range

   •  Reposition to be within 30 ft (9 m) of an RF signal 

repeater.

Attached lights 
turn OFF shortly 
after being turned 
ON.

Wiring

   •   Wiring error. Wire the Hybrid Keypad according to 

the 

Installation

 section and the appropriate 

Wiring 

Diagram

.

Load is less than minimum load requirement

   •  Make sure the connected load meets the 

appropriate minimum load requirement for that 
control. See 

Load Specifications

.

All LEDs on the 
Hybrid Keypad 
flash when any 
button is pressed.

The Hybrid Keypad is in Factory Settings mode and has 
not been configured to work in a system.

•  Follow the steps in t

he system Setup Guide to program 

the Hybrid Keypad.

Wallplate is warm

Solid-state control dissipation

   •  Solid-state Hybrid Keypads internally dissipate 

about 2% of the total connected load. It is normal 
for Hybrid Keypads to feel warm to the touch during 
operation.

Note: Refer to th

e

 system Setup Guide for additional troubleshooting 

suggestions.

Returning Hybrid Keypads to Factory Settings

Returning a Hybrid Keypad to its Factory Settings will remove it from the 
system and erase all dimmer settings and keypad programming.

Step 1:  

Triple tap any button (except raise / lower) on the Hybrid Keypad. DO 
NOT release after third tap.

Step 2:  

Keep the button pressed on the third tap until all the status LEDs start 
to flash slowly (approximately 3 seconds).

Step 3:  

Immediately release the button and triple tap the button again. The 
status LEDs on the Hybrid Keypad will flash quickly.

The Hybrid Keypad has now been returned to Factory Settings.

Warranty: 

For warranty information, please see the Warranty enclosed with the 

product, or visit www.lutron.com/resiinfo

English

Mounting Diagram

Wallplate adapter and wallplate 
purchased separately.

NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. Lutron, Claro, Satin Colors, RadioRA and   are registered trademarks and RadioRA 2 and FASS are trademarks of 
Lutron Electronics Co., Inc.    
©2011 Lutron Electronics Co., Inc.

Technical Assistance:

 

U.S.A. and Canada (24 hrs / 7 days)

 

Brazil (Monday-Friday 8:30am - 5:30pm BRT)

1.800.523.9466 

 

 

+55 (11) 3257.6745

Mexico 8am – 8pm ET 

 

Other countries 8am – 8pm ET

+1.888.235.2910 

 

 

+1.610.282.3800

Use these instructions to install the model numbers listed above. 

For system Setup Guide and tools visit: www.lutron.com/radiora2

Designer-style Hybrid Keypad

120 V

~

  50 / 60 Hz

Typical Power Consumption*:

 0.75 W

Remote Dimmer: RD-RD

Typical Power Consumption*: 0 W

* Typical Power Consumption test conditions: load is off, all backlights on medium intensity, two LEDs on 

(two presets active), keypad powered at 120 V

Twist wire 

connector 

tight.

O

N

O

F

F

O

N

O

F

F

O

N

O

F

F

Wiring Diagram 2b

RRD-H1RLD
RRD-H2RLD

RRD-H3BSRL
RRD-H4S

RRD-H5BRL
RRD-H6BRL

NOTE:  Orientation arrow MUST point UP.

Status LEDs

Show which 

button 

has been 

activated.

Raise / Lower Buttons 

Lights increase / decrease in intensity and 

shades / draperies raise / lower.

FASS

T

 

Front 

Accessible 

Service 

Switch

Keypad Buttons

Press to activate desired levels of lighting or 

positions of shades /draperies.
By default, the internal dimmer is controlled by the 

top keypad button. Tap to toggle load ON / OFF.

Replacement 

Kit

Keypad 

Mounting 

Screws

Adapter 

Mounting 

Screws

Wallplate 

Adapter

Wallplate

O

N

O

F

F

O

N

O

FF

O

N

O

FF

Wallbox

Hybrid 

Keypad