Multi-Location Installation without Neutral
2, 3
Brass
Black
Blue
Green
Ground
Lighting
Load
Hybrid Keypad or
Remote Dimmer
Brass
Black
Blue
Green
Ground
Remote Dimmer or
Hybrid Keypad
120 V
50 / 60 Hz
Brass
Black
Blue
Green
Ground
Hot/Live
Neutral
Remote Dimmer or
Hybrid Keypad
Silver
Multi-Location Installation with Neutral
3, 4
Brass
Silver
Black
Blue
Green
Ground
Brass
Black
Blue
Green
Ground
Remote Dimmer
120 V
50 / 60 Hz
Brass
Black
Blue
Green
Ground
Hot/Live
Neutral
Remote Dimmer
Hybrid Keypad
Wiring Diagram 1b
Lighting
Load
Single Location Installation without Neutral
1, 2
Wiring Diagram 2a
Brass
Black
Blue
1
Green
Ground
Hot/Live
Neutral
Lighting
Load
Hybrid Keypad
120 V
50 / 60 Hz
Silver
Single Location Installation with Neutral
1
Wiring Diagram 1a
120 V
50 / 60 Hz
Brass
Silver
Black
Blue
1
Green
Ground
Hot/Live
Neutral
Hybrid Keypad
Lighting
Load
Load Specifications:
1
Load Type:
Hybrid Keypads are designed for use with permanently installed incandescent, magnetic
low-voltage, or tungsten halogen only. To reduce the risk of overheating and possible damage to other
equipment, do not install Hybrid Keypads to control receptacles or motor-operated appliances.
2
Low-Voltage Applications:
Use Hybrid Keypads with magnetic (core and coil) low-voltage transformers
only. Not for use with electronic (solid-state) low-voltage transformers. Operation of a low-voltage circuit
with lamps inoperative or removed may result in transformer overheating and premature failure. Lutron
strongly recommends the following:
•
Do not operate low-voltage circuits without operative lamps in place.
•
Replace burned-out lamps as quickly as possible.
•
Use transformers that incorporate thermal protection or fused transformer primary windings to
prevent transformer failure due to overcurrent.
Important Notes
WARNING -
Entrapment hazard -
To avoid the risk of entrapment,
serious injury, or death, these controls must not be used to control
equipment which is not visible from every control location or which
could create hazardous situations such as entrapment if operated accidentally.
Examples of such equipment which must not be operated by these controls
include (but are not limited to) motorized gates, garage doors, industrial doors,
microwave ovens, heating pads, etc. It is the installer’s responsibility to ensure
that the equipment being controlled is visible from every control location and
that only suitable equipment is connected to these controls. Failure to do so
could result in serious injury or death.
Codes:
Install in accordance with all local and national electrical codes.
Grounding:
When no “grounding means” exist in wallbox, the 2011 National
Electrical Code
R
(NEC
R
) allows a control to be installed as a replacement if 1)
a nonmetallic, noncombustible faceplate is used with nonmetallic attachment
screws or 2) the circuit is protected by a ground fault circuit interrupter (GFCI).
When installing a control according to these methods, cap or remove green
wire before screwing control into wallbox.
Neutral Wire:
Hybrid Keypads have an available neutral wire terminal that can
be connected to the neutral wire in a wallbox where the Hybrid Keypad is to
be installed. Connecting the neutral wire to a Hybrid Keypad allows a lower
minimum load to be used. Also, normal keypad operation will be available even
if the attached load is not installed or if the lamp is burned out. If a neutral
wire connection is available, connect it to the silver terminal. If a neutral wire
connection is desired but not available in the wallbox, contact a licensed
electrician for installation.
Environment:
Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C),
0% to 90% humidity, non-condensing. Indoor use only.
Spacing:
If mounting one control above another, leave at least 4 ½ in (114 mm)
vertical space between them.
Wallplates:
Lutron
R
Claro
R
and Satin Colors
R
wallplates are strongly
recommended for best color match and clean aesthetic appearance. Do not
paint keypads, buttons, or wallplates.
Cleaning:
To clean, wipe with a clean damp cloth.
Do NoT
use any chemical
cleaning solutions.
Wallboxes:
Lutron recommends using 3 ½ in (89 mm) deep wallboxes for easier
installation. Several controls may be installed in one multigang wallbox.
Remote Dimmers:
Use only Remote Dimmers (RD-RD) with Hybrid Keypads.
Up to 9 RD-RD controls may be used with a Hybrid keypad.
RF Device Placement:
RF dimmers, switches, keypads and shades / draperies
must be located within 30 ft (9 m) of an RF signal repeater. For systems without
an RF signal repeater, all RF dimmers, switches, keypads and shades / draperies
must be located within 30 ft (9 m) of each other. Remote dimmers and switches
are not required to be within a specific range.
Engraving:
The Prepaid Engraving Certificate included with the Hybrid
Keypad can be redeemed for a custom engraved replacement kit. To order a
replacement kit please follow the instructions at: www.lutron.com/buttons
Load Type
1
Minimum Load
Maximum Load
With Neutral
Without Neutral
Incandescent
15 W
50 W
450 W
MLV
2
15 W / VA
50 W / VA
350 W / 450 VA
Multigang Installations
In multigang installations, several controls are grouped horizontally in one
multigang wallbox. When combining controls in a wallbox, derating is required;
however, no derating is required for Remote Dimmers.
Derating Chart
Load Type
End of Gang
Middle of Gang
Incandescent
350 W
250 W
MLV
250 W / 350 VA
200 W / 250 VA
Installation
WARNING -
Shock hazard -
To avoid the risk of electric shock,
locate
and remove fuse or lock circuit breaker in the OFF position before
proceeding. Wiring with power ON could result in serious injury or death.
1.
Turn power OFF at fusebox or circuit breaker.
2.
Check the installation for short circuits before installing control(s). With power
OFF, install standard mechanical switch(es) between Hot and load. Restore
power. If lights do not work or a breaker trips, check wiring. Correct wiring
and check again. Install control(s) only when short is no longer present.
Warranty is void if keypad is installed in a shorted circuit.
3.
Wire keypads according to one of the following options:
a.
Terminals:
Trim or strip wallbox wires to the length indicated by the strip gauge on the
back of the keypad.
• Push-In Terminals: Use with 14 AWG (1.5 mm
2
)
solid copper wire
only
. DO NOT use stranded or twisted wire.
Insert wires fully. To release wire, insert small, flat screwdriver into slot
below push-in terminal. Push screwdriver in while pulling wire out.
OR
• Screw Terminals:
use with 12 AWG (2.5 mm
2
) or 14 AWG (1.5 mm
2
)
solid copper wire only
. DO NOT use stranded or twisted wire.
Wrap wire around screw terminal. Tighten securely to 5 in-lb (0.55 N•m).
b.
Wire Connectors:
Prepare wires. When making wire connections, follow the recommended
strip lengths and combinations for the supplied wire connector.
Note: Wire connector provided is suitable
for copper wire only.
Wire Connector:
• Strip insulation 3/8 in (10 mm) for 14 AWG (1.5 mm
2
)
or 12 AWG (2.5 mm
2
) wire
• Strip insulation 7/16 in (11 mm) for 18 AWG
(0.75 mm
2
) wire
• Use to join one or two 14 AWG (1.5 mm
2
) or 12 AWG
(2.5 mm
2
) wires with one 18 AWG (0.75 mm
2
) ground wire.
For installations WITH a neutral wire:
See
Wiring Diagrams 1a
or
1b
.
For installations WITHOUT a neutral wire:
See
Wiring Diagram 2a
or
2b
.
Note: If a neutral wire connection is available, connect it to the silver terminal.
4.
Push all wires back into the wallbox and loosely fasten the Hybrid Keypad to the
wallbox using the control mounting screws provided. Do not pinch the wires.
5.
Attach Lutron
R
Claro
R
or Satin Colors
R
wallplate adapter and wallplate. See
the
Mounting Diagram
.
a. Install the wallplate adapter onto the front of the Hybrid Keypad.
b. Tighten the keypad mounting screws until wallplate adapter is flush to the
wall (do not over-tighten).
c. Snap the wallplate onto the wallplate adapter and verify that the Hybrid
Keypad is aligned properly.
d. If the Hybrid Keypad is misaligned, remove wallplate and loosen the
mounting screws to adjust the Hybrid Keypad appropriately. When the Hybrid
Keypad is alligned properly, snap the wallplate onto the wallplate adapter.
6.
Restore power. Check for correct local operation. See
operation
.
Installation Instructions
Please Read Before Installing
1
When using controls in single location installations, tighten the blue terminal without any
wires attached. DO NOT connect the blue terminal to any other wiring or to ground.
2
In installations without a neutral wire connection, tighten the silver terminal without any
wires attached. DO NOT connect the silver terminal to any other wiring or to ground.
3
Up to 9 Remote Dimmers may be connected to the Hybrid Keypad. Total blue terminal
wire length may be up to 250 ft (76 m).
4
Neutral wire Hybrid Keypads must be connected on the load side of a multi-location
installation.
operation
Lamp Replacement
WARNING -
Shock hazard -
For any procedure other than routine lamp
replacement, power must be disconnected at the main electrical panel.
Working with power ON could result in serious injury or even death.
For routine lamp replacement, remove power from the fixture(s) by pulling the
FASS
T
switch out on both the Hybrid Keypad and all Remote Dimmers
Troubleshooting Guide
Lutron Elec tron ics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299
P/N 044-299 Rev. A 10/2011
Symptom
Probable Cause and Action
Lights do not
respond to a
Hybrid Keypad
button press
or do not go to
desired levels.
Improper programming
• Program according to the system Setup Guide.
If the system is GUI programmed, ensure that the load
has been assigned to the keypad button in the GUI.
If the system is programmed through walk-around
programming, ensure that the load has been assigned to
the keypad button.
Power not present at keypad
• Circuit breaker tripped or OFF. Reset or turn ON
circuit breaker.
The FASS
T
switch is pulled out.
• Push
FASS
T
switch in.
Wiring
• Wires shorted. Make sure the blue terminal is not
grounded or shorted to any other wires.
• Wiring error. Wire the Hybrid Keypad according to
the
Installation
section and the appropriate
Wiring
Diagram
.
Lamps burned out or not installed
• Replace or install lamps.
Dioded lamps
• If dioded lamps are being used, replace with
non-dioded lamps.
Out of RF range
• Reposition to be within 30 ft (9 m) of an RF signal
repeater.
Attached lights
turn OFF shortly
after being turned
ON.
Wiring
• Wiring error. Wire the Hybrid Keypad according to
the
Installation
section and the appropriate
Wiring
Diagram
.
Load is less than minimum load requirement
• Make sure the connected load meets the
appropriate minimum load requirement for that
control. See
Load Specifications
.
All LEDs on the
Hybrid Keypad
flash when any
button is pressed.
The Hybrid Keypad is in Factory Settings mode and has
not been configured to work in a system.
• Follow the steps in t
he system Setup Guide to program
the Hybrid Keypad.
Wallplate is warm
Solid-state control dissipation
• Solid-state Hybrid Keypads internally dissipate
about 2% of the total connected load. It is normal
for Hybrid Keypads to feel warm to the touch during
operation.
Note: Refer to th
e
system Setup Guide for additional troubleshooting
suggestions.
Returning Hybrid Keypads to Factory Settings
Returning a Hybrid Keypad to its Factory Settings will remove it from the
system and erase all dimmer settings and keypad programming.
Step 1:
Triple tap any button (except raise / lower) on the Hybrid Keypad. DO
NOT release after third tap.
Step 2:
Keep the button pressed on the third tap until all the status LEDs start
to flash slowly (approximately 3 seconds).
Step 3:
Immediately release the button and triple tap the button again. The
status LEDs on the Hybrid Keypad will flash quickly.
The Hybrid Keypad has now been returned to Factory Settings.
Warranty:
For warranty information, please see the Warranty enclosed with the
product, or visit www.lutron.com/resiinfo
English
Mounting Diagram
Wallplate adapter and wallplate
purchased separately.
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. Lutron, Claro, Satin Colors, RadioRA and are registered trademarks and RadioRA 2 and FASS are trademarks of
Lutron Electronics Co., Inc.
©2011 Lutron Electronics Co., Inc.
Technical Assistance:
U.S.A. and Canada (24 hrs / 7 days)
Brazil (Monday-Friday 8:30am - 5:30pm BRT)
1.800.523.9466
+55 (11) 3257.6745
Mexico 8am – 8pm ET
Other countries 8am – 8pm ET
+1.888.235.2910
+1.610.282.3800
Use these instructions to install the model numbers listed above.
For system Setup Guide and tools visit: www.lutron.com/radiora2
Designer-style Hybrid Keypad
120 V
~
50 / 60 Hz
Typical Power Consumption*:
0.75 W
Remote Dimmer: RD-RD
Typical Power Consumption*: 0 W
* Typical Power Consumption test conditions: load is off, all backlights on medium intensity, two LEDs on
(two presets active), keypad powered at 120 V
Twist wire
connector
tight.
O
N
O
F
F
O
N
O
F
F
O
N
O
F
F
Wiring Diagram 2b
RRD-H1RLD
RRD-H2RLD
RRD-H3BSRL
RRD-H4S
RRD-H5BRL
RRD-H6BRL
NOTE: Orientation arrow MUST point UP.
Status LEDs
Show which
button
has been
activated.
Raise / Lower Buttons
Lights increase / decrease in intensity and
shades / draperies raise / lower.
FASS
T
Front
Accessible
Service
Switch
Keypad Buttons
Press to activate desired levels of lighting or
positions of shades /draperies.
By default, the internal dimmer is controlled by the
top keypad button. Tap to toggle load ON / OFF.
Replacement
Kit
Keypad
Mounting
Screws
Adapter
Mounting
Screws
Wallplate
Adapter
Wallplate
O
N
O
F
F
O
N
O
FF
O
N
O
FF
Wallbox
Hybrid
Keypad