Lutron Electronics MS-7011 Operation Manual Download Page 2

TABLE OF CONTENTS

1. FEATURES.............................................................

1

2. SPECIFICATIONS...................................................

2

3. FRONT PANEL DESCRIPTION..................................

6

3-1 Display.............................................................

6

3-2 Power Button...................................................

6

3-3 REC. Button......................................................

6

3-4 Hold Button......................................................

6

3-5 ,  

Button.....................................................

℃ ℉

6

3-6 Function Button ...............................................

6

3-7 Battery Compartment/Cover..............................

6

3-8 Temp. Probe input Socket ................................

6

3-9 Humidity Probe input Socket .............................

6

3-10 RS-232 Output Terminal..................................

6

3-11 Stand.............................................................

6

3-12 Probe Plug .....................................................

6

3-13 Probe handle..................................................

6

3-14 Probe main body.............................................

6

3-15 Sensing head with inner filter..........................

6

3-16 Protection cover for Sensing head....................

6

4.   MEASURING PROCEDURE.....................................7

4-1 Humidity content measurement.........................7
4-2 Dew point measurement................................... 8
4-3 Type K thermometer measurement....................8
4-4 Data Hold.........................................................8
4-5 Data Record (Max, Min reading)........................ 9

5. OFFSET TEMPERATURE ADJUSTMENT for

 Type K THERMOMETER......................................... 10

6. AUTO POWER OFF DISABLE................................... 12

7. RS232 PC SERIAL INTERFACE.................................12

8. BATTERY REPLACEMENT........................................13

9. OPTIONAL PROBES & ACCESSORIES.......................14

Summary of Contents for MS-7011

Page 1: ...x and delicate instrument its durable structure developed Please read the following instructions carefully and always keep this manual within easy reach OPERATION MANUAL Heavy duty probe Dew point Typ...

Page 2: ...6 3 11 Stand 6 3 12 Probe Plug 6 3 13 Probe handle 6 3 14 Probe main body 6 3 15 Sensing head with inner filter 6 3 16 Protection cover for Sensing head 6 4 MEASURING PROCEDURE 7 4 1 Humidity content...

Page 3: ...ure linearity and precision cold junction compensation circuit high accuracy Microprocessor circuit assures maximum possible accuracy provides special functions and features Large LCD with two display...

Page 4: ...ty Content High precision thin film capacitance sensor Temperature Thermistor Type K Thermocouple probe thermometer Data Hold Freeze the display reading by push button Memory Maximum Minimum value Rec...

Page 5: ...Meter 195 x 68 x 30 mm 7 6 x 2 6 x 1 2 inch Humidity Probe length 600 mm Content Probe head diameter 10 mm Probe Cable length 1 5 meters Accessories Instruction manual 1 PC Included Humidity content p...

Page 6: ...70 RH 3 RH Range 0 to 50 32 to 122 Temp Resolution 0 1 degree Accuracy 0 8 1 5 Dew Point Range 25 3 to 48 9 Resolution 0 1 Range 13 5 to 120 1 Resolution 0 1 Remark Dew Point display value is calculat...

Page 7: ...Type K Thermometer Range 100 0 to 1300 0 Resolution 0 1 Accuracy 50 0 to 1300 0 0 2 0 5 50 1 to 100 0 0 2 1 Range 148 0 to 2372 0 Resolution 0 1 Accuracy 58 0 to 2372 0 0 2 1 58 1 to 148 0 0 2 1 8 5...

Page 8: ...3 5 Button 3 6 Function Button 3 7 Battery Compartment Cover 3 8 Temp Probe input Socket 3 9 Humidity Probe input Socket 3 10 RS 232 Output Terminal 3 11 Stand 3 12 Probe Plug 3 13 Probe handle 3 14 P...

Page 9: ...3 15 Fig 1 4 Penetrate the Sensing head 3 15 Fig 1 along with Probe main body 3 14 Fig 1 into the measurement materials such as Grain Corn Rice Cotton Paper refer to Fig 2 The meter s display will sho...

Page 10: ...3 6 Fig 1 the LCD will show the unit DEW or 4 3 Type K thermometer measurement 1 Take out the humidity probe away from the Humidity Probe input Socket 3 9 Fig 1 If not take out the humidity probe the...

Page 11: ...he maximum value just press the Hold Button 3 4 Fig 1 for a while then the display will show the REC symbol only execute the memory function continuously b Press the REC Button 3 3 Fig 1 again the REC...

Page 12: ...on the front panel However in general conditions customers are always not recommended to execute the Offset Temperature Adjustment Procedures without qualified calibration equipment Offset Temp Adjust...

Page 13: ...er digits 0 0 0 2 6 When desired value available release the fingers from the Hold Button 3 4 Fig 1 and REC Button 3 3 Fig 1 to finish the Offset Temperature Adjustment Procedures CONSIDERATION The ca...

Page 14: ...ata Record function with a REC symbol on the display for long period measurement 7 RS232 PC SERIAL INTERFACE The instrument has RS232 PC serial interface via a 3 5 mm terminal 3 10 Fig 1 The data outp...

Page 15: ...D9 Decimal Point DP position from right to the left 0 No DP 1 1 DP 2 2 DP 3 3 DP D8 to D1 Display reading D1 LSD D8 MSD For example If the display reading is 1234 then D8 to D1 is 00001234 D0 End Word...

Page 16: ...ple 40 to 482 Probe Ultra fast response naked bead Model TP 01 thermocouple general purpose application Type K Measure Range 50 to 900 Thermocouple 50 to 1650 Probe Dimension 10 cm tube 8 mm Dia Model...

Reviews: