background image

HomeWorks Digital 0.1% Constant Voltage Controller

®

S P E C I F I C AT I O N   S U B M I T TA L

Page

Job Name:

Job Number:

Model Numbers:

LED Dimming Controller

Architectural Dimming

3691213a   2   06.01.21

Specifications

Regulatory Approvals and Compliance

• Lutron Quality Systems registered to ISO 9001.2015
• Manufacturing facilities employ ESD reduction 

practices that comply with the requirements of 
ANSI / ESD  S20.20

• Meets ANSI C62.41 category A surge protection 

standards up to and including 4 kV

• FCC Part 15 
  – Class A (277 V

~

)

  – Class B (120 V

~

)

• CAN ICES‑005 (A) (277 V

~

)

• CAN ICES‑005 (B) (120 V

~

)

• LED controllers need to meet certain performance 

criteria in order for the completed luminaires to comply 
with Title 24 2019 requirements as detailed in Joint 
Appendix 8. All models meet both commercial  
(at 120 V

~

 / 277  V

~

) and residential (at 120 V

~

performance criteria throughout their entire load 
operating regions. Consult 2019 Residential 
Compliance Manual, Example 6‑3 Fade‑in Lighting 
for important information on meeting start‑up time 
requirements with fade‑in lighting.

• Meets UL

®

 8750 / CSA C22.2 No. 250.13‑14, “Light Emitting 

Diode (LED) Equipment For Use in Lighting Products”

• Class 2 output; meets UL

®

 1310 / CSA C22.2 No. 223‑M91

Performance

• Dimming Range: 100% to 0.1% 

1

• LED lighting turns on to any dimmed level without 

flashing to full brightness

• Operating Voltage: 120 / 277 V

~

 at 50 / 60 Hz

•  Rated lifetime of 50,000 hours at 40 °C (104 °F) 

ambient temperature and maximum loading

• For rated warranty, ambient temperature (t

a

) not to 

exceed 40 °C (104 °F) (maximum rated temperature) 

2, 3

• Patented thermal fold back protection
• Non‑volatile memory restores all controller settings 

after power failure

• Typical standby power consumption: 0.25 W at 

120 V

~

 and  0.4 W at 277 V

~

• Open‑circuit protected output
• Short‑circuit and overload‑protected output
• Output: 24 V

-

 constant voltage at high‑end

• Output Load Range: 2 W to 96 W at high‑end
• Power Factor: > 0.90 at maximum power
• Total Harmonic Distortion (THD): < 20% at 

maximum power

• NEMA 410 – 2011 compliant
• Inrush Current Limiting Circuitry: decreases circuit 

breaker tripping, switch arcing and relay failure; allows 
full loading of switch leg

• Inrush Current: < 2 A
• Device turn‑on time: < 100 ms from electronic off and, 

< 500 ms from power off

• LHD0‑96W24V‑U controller is programmed by Lutron 

manufacturing and is NOT configurable by the Lutron 
QwikFig configuration system

1

  Light output at 0.1% depends on installation and light engine efficacy.

2

  To maintain warranty, installer is responsible for ensuring that the controller ambient temperature does not exceed 40 ºC (104 ºF).

3

  Where t

a

 is the temperature of the air directly surrounding the controller.

2

Summary of Contents for LHD0-96W24V-U UL

Page 1: ...Guaranteed dimming performance when used with Lutron controls HomeWorks digital module Lutron 3 wire controls and interfaces Protected from miswires of input power up to 277 V to HomeWorks digital con...

Page 2: ...100 to 0 1 1 LED lighting turns on to any dimmed level without flashing to full brightness Operating Voltage 120 277 V at 50 60 Hz Rated lifetime of 50 000 hours at 40 C 104 F ambient temperature and...

Page 3: ...grounded by terminal connection Must be permanently connected fixed wiring for 277 V application Terminal blocks on the controller accept solid or stranded wire per terminal from 20 AWG to 12 AWG 0 5...

Page 4: ...For wiring options see Wiring section pages 8 10 NOTE Specifications are subject to change without notice Output Voltage vs Output Power Output Power W Output Power W Output Power W Output Voltage V...

Page 5: ...e Job Name Job Number Model Numbers LED Dimming Controller Architectural Dimming 3691213a 5 06 01 21 Enclosure Dimensions Measurements are shown as in mm Knockouts Sides 4 locations 1 2 in or 21 mm tr...

Page 6: ...tural Dimming 3691213a 6 06 01 21 Mounting Options1 2 1 Any other mounting configuration will require additional mechanical support Improper installation may result in hazards to personnel or property...

Page 7: ...links are wired as Class 2 or between the HomeWorks digital control and output terminals Option 2 when the HomeWorks digital links are wired as Class 1 For 3 wire control barrier could be placed in ei...

Page 8: ...7 1 6 1 14 Maestro Wireless dimmer MRF2 F6AN DV 1 6 1 14 RadioRA 2 dimmer RRD F6AN DV 1 6 1 14 Dual voltage 3 wire dimmer 21 4 HomeWorks QS dimmer HQRD F6AN DV 1 6 1 14 Fluorescent 3 wire LED 3 wire 2...

Page 9: ...chart below For assistance selecting controls contact our LED Center of Excellence at 1 844 LUTRON1 U S A and Canada only or LEDs lutron com Product Model Number Recommended System Version Controllers...

Page 10: ...consult load manufacturer best practices for any additional consideration in load installation When connecting several LED light homeruns ensure that the wire lengths and wattages match as closely as...

Page 11: ...erminal Make sure that the supply breaker to the controllers and HomeWorks digital link supply is OFF when wiring HD1 and HD2 terminals of the controllers can be daisy chained as shown to the right Us...

Page 12: ...The Field Adjustment Knob cannot fix light level mismatch among loads on the same controller For example two homeruns of different wattage For increasing the minimum light output of all the controlle...

Page 13: ...signed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in...

Reviews: