Description
The NGRX-PB increases the GRX-3000 Main Control
single zone load capacity (Incandescent, Magnetic
Low Voltage, and Neon/Cold Cathode only) to
2000W/VA.
It mounts in a standard 2-gang wallbox (minimum
depth: 2 3/4”, recommended depth: 3 1/2”).
Note: The load of low voltage inductive transformers in VA=
the low-voltage lamp watts x 1.3 (representing a 30%
loss due to the transformers). Example: 5 low-voltage
lamps at 50W each= 250 lamp watts x 1.3 = 325VA.
Installation & Operation
New Installations:
Check each zone for short or open circuits. Turn
power off. Connect a standard switch between the hot
lead and that zone’s load wire, then turn power on. If
the load device does not operate, the circuit is open.
If the breaker trips (fuse blows), the circuit is shorted.
Correct any open or shorted condition and test again
before proceeding.
1.
Turn power off to GRX 3000 Series Main Control
Unit and the feed to the NGRX-PB Power Booster.
Warning:
Always turn off the circuit breaker or remove the
main fuse from the power line before doing any
work. Failure to do so can result in serious
personal injury.
2.
Strip insulation from wallbox wires as shown:
3.
Connect wiring as shown in Figure 1. Each
terminal will accept up to two wires (#12 to #18
AWG). Use 75 C° copper (CU) wire only.
Terminal tightening torque= 9in/lb.
3000
Series
DO NOT WIRE HOT
UP
UP
NGRX-PB, 2000W/V
A
120V
AC, 1600W/V
A
100V
AC
LUTRON
LISTED 243C IND. CONTROL
EQUIP
.
COOPERSBURG, P
A
USA
U
L
+
+
D HOT OUT
HOT IN
CONTROL
NEUTRAL
NGRX-PB
GRX-3002 GRX-3004
GRX-3003 GRX-3006
LUTRON
20A BREAKER
FROM
DISTRIBUTION
PANEL
EUTRAL FROM
TRIBUTION PANEL
LOAD
Any Zone
Figure 1. Wiring Diagram
Important Notes:
1. This control must be installed by a qualified
electrician.
2. Install in accordance with all applicable regulations.
3. Improper wiring can result in personal injury,
damage to the control, or damage to other
equipment.
4. Use only with core-and-coil (magnetic) type low
voltage transformers. Before attempting to
control a solid-state low voltage transformer,
call Lutron’s toll-free hotline and ask for
Application Note No. 19, Guide to Dimming
Low-Voltage Lighting (part number 362-219).
5. In dimmed low-voltage circuits, to avoid
excessively high current flow that can cause
transformer overheating and failure:
(a) Do not operate the unit with all of the lamps
removed or with any inoperative lamps.
(b) Replace any burned out lamps immediately.
(c) Use only transformers which incorporate
thermal protection or fused primary windings.
To 20A
breaker in
Distribution
Panel
To Neutral in
Distribution
Panel
Dimmed Hot from any zone
NGRX-PB
POWER BOOSTER
For Incandescent, Magnetic Low Voltage,
and Neon/ Cold Cathode Loads