The data stream will be displayed in the following 

format :
gram 

11 digit data stream :

 D10    D9    D8    D7    D6    D5    D4    D3    D2    D1

Each digit indicate the following status :

D0

CR

CR = Enter (code is "A")

D1

LF

LF = Line feed (code is "D")

D2

g

D3 to D5

SPACE

D6 to D9

Display reading, D6=LSD, D9=MSD

D10

SPACE

oz

12 digit data stream :

 D11    D10    D9    D8    D7    D6    D5    D4    D3    D2    D1

Each digit indicate the following status :

D0

CR

CR = Enter (code is "A")

D1

LF

LF = Line feed (code is "D")

D2

Z

D3

O

D4 to D5

SPACE

D6 to D10

Display reading, D6=LSD, D10=MSD

D11

SPACE

7

9805-GM-500

Summary of Contents for GM-500

Page 1: ...SCALE marks a step forward for you into the field of precision measurement Although this DIGITAL SCALE is a complex and delicate instrument its durable structure developed Please read the following in...

Page 2: ...Button 2 3 3 Display 2 3 4 Power Switch 2 3 5 Rubber Pads 2 3 6 Battery Cover Compartment 2 3 7 DC 9V receptacle 2 3 8 RS232 Output Socket 2 3 9 Calibration Face Plate 2 3 10 Unit Switch 2 4 PLATFORM...

Page 3: ...clusive microprocessor LSI circuit high reliability 2 SPECIFICATIONS Display 18 mm 0 7 LCD 5 digits w annunciator Measuring Capacity 500 0 g 17 6 oz Resolution 0 1 g 0 005 oz Min Display Weight 0 3 g...

Page 4: ...hat use WT 200 optional for executing the self calibration RS 232 cable RS 232 cable for connecting between Model UPCB 01 scale the computer optional Software Counting scale software optional SCALE U0...

Page 5: ...3 2 Calibration Button 3 2a Tare Button 3 3 Display 3 4 Power Switch 3 5 Rubber Pads 3 6 Battery Cover Compartment 3 7 DC 9V receptacle 3 8 RS232 Output Socket 3 9 Calibration Plate 3 10 Unit Switch 4...

Page 6: ...but the LCD display will not show any marker 3 Turn the Power Switch 3 4 Fig 1 to the On position The Display 3 3 Fig 1 will show 8 8 8 8 8 for a few seconds then 0 will appear again 4 Apply the load...

Page 7: ...for the measurement accurately Consideration of Self Calibration The internal Self Calibration correction data is save to the memory circuit a while Once power off then the correction data will disapp...

Page 8: ...the scale is ready for ACV operation 9 RS232 PC SERIAL INTERFACE The instrument features an RS232 output via 3 5 mm Terminal 3 8 Fig 1 The connector output is a 11 digit data stream for gram 12 digit...

Page 9: ...CR Enter code is A D1 LF LF Line feed code is D D2 g D3 to D5 SPACE D6 to D9 Display reading D6 LSD D9 MSD D10 SPACE oz 12 digit data stream D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 Each digit indicate the...

Reviews: