Lutron Electronics EM-1910 Operation Manual Download Page 1

 Sound level, 7 in 1

ENVIRONMENT METER

 Model : EM-1910

Your purchase of this
ENVIRONMENT METER.
7 in 1 . marks a
step forward for you
into the field of
precision measurement.
Although this Meter is a
complex and delicate
instrument, its durable
structure will allow
many years of use if
proper operating
techniques are
developed. Please read
the following
instructions carefully
and always keep this
manual within easy
reach.

 OPERATION MANUAL

Summary of Contents for EM-1910

Page 1: ...rd for you into the field of precision measurement Although this Meter is a complex and delicate instrument its durable structure will allow many years of use if proper operating techniques are develo...

Page 2: ...11 Button operation label 6 3 12 Type K probe socket 6 3 13 Tripod Fix Nut 6 4 MEASURING PROCEDURES 7 4 1 Power on off 7 4 2 LCD backlight on off 7 4 3 Function selection 7 4 4 Unit selection 8 4 5 Re...

Page 3: ...ing with one hand Wristlet design provides extra protection to the instrument especially for user one hand operation High precision humidity sensor with fast response time Built in microprocessor circ...

Page 4: ...k Temp optional Operating Max 80 RH Humidity Operating 0 to 50 32 to 122 Temperature Over Input Indication of Display Power Supply UM4 AAA X 3 DC 4 5 V battery Power Approx DC 18 mA Consumption Weight...

Page 5: ...lass 2 Under 94 dB input signal the accuracy are 31 5 Hz 3 0 dB 63 Hz 2 0 dB 125 Hz 1 5 dB 250 Hz 1 5 dB 500 Hz 1 5 dB 1 K Hz 1 0 dB 2 K Hz 2 0 dB 4 K Hz 3 0 dB 8 K Hz 5 0 dB Remark The above spec are...

Page 6: ...x 10 Lux Ft cd 0 to 204 0 Fc 0 1 Ft cd 170 to 1 860 Fc 1 Ft cd Remark Ft cd feet candle Dew point Temp Unit Range Resolution Remark 25 3 to 49 0 0 1 Calculate from the 13 5 to 120 0 0 1 humidity Temp...

Page 7: ...values Celsius Fahrenheit Notes 27 32 80 90 Caution Fatigue is possible with prolonged exposure and activity Continuing activity could result in heat cramps 32 41 90 105 Extreme caution Heat cramps an...

Page 8: ...ton Power button 3 3 REC Button 3 4 LCD display 3 5 Wristlet 3 6 Lux Light Sensor 3 7 Sound level sensor mic 3 8 Humidity Temp sensor 3 9 RS 232 socket 3 10 Battery Compartment Cover 3 11 Battery Cove...

Page 9: ...3 seconds will power off 4 2 LCD backlight on off During power on press Power Button once then the LCD backlight will be on 5 seconds then off automatically 4 3 Function selection The meter can select...

Page 10: ...er tYPE Type K Temp optional Until the Display show the desired function just release the Hold button the meter will execute this function with default 4 4 Unit selection 1 During power on press the R...

Page 11: ...at index Light meter Lux Ft cd auto range Type K Temp 4 5 Reverse the Display direction automatically As intend to match the sensor convenient position Light sensor should put on the top case side to...

Page 12: ...convenience of going to the sensor position The humidity sensor should be placed under the top case side so as to prevent when Hold the case will not affect the humidity sensor detector if want to cha...

Page 13: ...mum value will appear on the display b Press the REC button again the MIN symbol along with the minimum value will appear on the display c To exit the memory record function press the REC button conti...

Page 14: ...Type K Temp measurement 5 RS232 PC SERIAL INTERFACE The instrument has RS232 PC serial interface via a 3 5 mm terminal 3 10 Fig 1 The data output is a 16 digit stream which can be utilized for user s...

Page 15: ...display reading is 1234 then D8 to D1 is 00001234 D9 Decimal Point DP position from right to the left 0 No DP 1 1 DP 2 2 DP 3 3 DP D10 Polarity 0 Positive 1 Negative D11 D12 Annunciator for Display 0...

Page 16: ...the cover 7 Optional Type K Temp probe Type K TP 01 Max short term operating Temperature 300 572 It is an ultra fast response naked bead thermocouple suitable for many general purpose application The...