background image

      52 Railroad Ave                                                    www.preciseled.com                       

      Valley Stream, NY 11580                                          [email protected]            

File Name: DRIV-LP-24V-96W SPEC A02   JAN. 5, 2020                                                                                                                                Page 

 

We reserve the right to change specifications without prior notice.

   

2020

 

PreciseLED 

DRIV-LP-24V-96W

Project Name:
Fixture Type:

Lutron LP Serise 24VDC, 5-96Watts 3-Wire/digital EcoSystem

120/277V 0.1% Dimming LED Driver

Hi-lume

®

 Premier 0.1% Constant Voltage Driver (L3D0)

®

S P E C I F I C AT I O N   S U B M I T TA L

Page

Job Name:

Job Number:

Model Numbers:

LED Dimming Driver

Architectural Dimming

369883c   14   09.13.16

Facilities Manager 

This device complies with part 15 of the FCC Rules. 
Operation is subject to the following two conditions:  
(1) This device may not cause harmful interference, 
and (2) this device must accept any interference 
received, including interference that may cause 
undesired operation.

NOTE:

 This equipment has been tested and found to 

comply with the limits for a Class B digital device, 
pursuant to part 15 of the FCC Rules. These limits are 
designed to provide reasonable protection against 
harmful interference in a residential installation. This 
equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful 
interference to radio communications. However, there 
is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause 
harmful interference to radio or television reception, 
which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the 
interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
—  Increase the separation between the equipment 

and receiver.

—  Connect the equipment into an outlet on a circuit 

different from that to which the receiver is 

connected.

—  Consult the dealer or an experienced radio/TV 

technician for help.

Service

Driver Warranty

For warranty information, please visit  
www.lutron.com/driverwarranty

Replacement Parts

When ordering Lutron

®

 replacement parts, please 

provide the full model number. Consult Lutron if you 
have any questions.

Further Information

For further information, please visit us at  
www.lutron.com or contact our LED Control Center of 
Excellence at 

1.877.346.5338

 (U.S.A. and Canada 

only) or 

[email protected]

14

Summary of Contents for DRIV-LP-24V-96W

Page 1: ...ing FCC Part 15 compliant for commercial applications at 120 277 V and residential applications at 120 V In rush limiting allows full loading of circuit breakers without nuisance tripping 1 Light output at 0 1 depends on installation and light engine efficacy 2 Soft on Fade to BlackTM dimming technology is not available for 3 wire controls Hi lume Premier 0 1 EcoSystem 3 wire Constant Voltage 24 V...

Page 2: ...ower failure Typical standby power consumption 0 25 W at 120 V and 0 4 W at 277 V Open circuit protected output Short circuit and overload protected output Output 24 V constant voltage at high end Output Load Range 25 W to 96 W at high end PWM dimming frequency meets IEEE1789 at all dim levels Power Factor 0 95 at maximum power Total Harmonic Distortion THD 20 at maximum power Performance continue...

Page 3: ...essed if service or troubleshooting is necessary Driver is grounded by terminal connection Terminal blocks on the driver accept solid or stranded wire per terminal from 20 AWG to 12 AWG 0 50 mm2 to 2 5 mm2 Maximum wire length between the LED driver and the start of the linear strip for different wire sizes is listed below The table below can be used independently of line voltage powering the LED D...

Page 4: ...ge V Input Current1 A Typical Power Factor1 Typical THD1 Output Power1 W Output Voltage1 V 3 Wire or EcoSystem Control2 For 24 V Constant Voltage LED Loads L3D0 96W24V U 120 0 92 0 99 7 5 25 96 24 277 0 40 0 97 11 25 96 24 1 At maximum output power 2 For wiring options see Wiring section pages 9 11 NOTE Specifications are subject to change without notice Power Factor vs Output Power THD vs Output P...

Page 5: ...ie 24 V 4 A Max Class 2 B2 Warranty void if inner plastic cover is removed Garantie annulée si le couvercle plastique intérieur est ouvert Field Adjustment Knob Bouton de Réglage pour utilisation en chantier Hi lume Premier 0 1 Suitable for damp locations Convient aux emplacements humides Use 20 12 AWG wire only Utiliser un fil de 0 50 2 5 mm seulement WARNING Shock hazard May result in serious in...

Page 6: ...oSystem 120 277V 0 1 Dimming LED Driver Hi lume Premier 0 1 Constant Voltage Driver L3D0 SPECIFICATION SUBMITTAL Page Job Name Model Numbers LED Dimming Driver Architectural Dimming 369883c 6 09 13 16 Mounting Options1 2 1 Any other mounting configuration will require additional mechanical support Improper installation may result in hazards to personnel or property 2 Mount the driver in a position ...

Page 7: ... 16 Barrier Installation and Driver Spacing Requirements Measurements are shown as in mm Optional barrier can be placed either between the input and control terminals Option 1 when the EcoSystem links are wired as Class 2 or between the control and output terminals Option 2 when EcoSystem links are wired as Class 1 For 3 wire control barrier could be placed in either location See Lutron Applicatio...

Page 8: ... Utiliser un fil 0 50 2 5 mm2 seulement Warranty void if inner plastic cover is removed Garantie annulée si le couvercle plastique intérieur est ouvert B2 LISTED LED Driver 4RM5 Hi lume Premier 0 1 WARNING Shock hazard May result in serious injury or death Disconnect power before opening top lid servicing or installing AVERTISSEMENT Danger d électrocution Peut causer de graves lésions ou le décès d...

Page 9: ... 16 1 19 NF 103P NF 103P 277 1 8 1 14 Skylark dimmer SF 10P SF 12P 277 1 8 1 14 SF 103P SF 12P 277 3 1 8 1 14 Diva dimmer DVF 103P DVF 103P 277 1 8 1 14 DVSCF 103P DVSCF 103P 277 1 8 1 14 Ariadni dimmer AYF 103P AYF 103P 277 1 8 1 14 Maestro dimmer MAF 6AM MAF 6AM 277 1 6 1 14 MSCF 6AM MSCF 6AM 277 1 6 1 14 Maestro Wireless dimmer MRF2 F6AN DV 1 6 1 14 RadioRA 2 dimmer RRD F6AN DV 1 6 1 14 Dual vo...

Page 10: ...Module with EcoSystem RMJ ECO32 DV B URMJ ECO32 DVB 5 9 or higher 32 per EcoSystem link PowPak Wireless Fixture Control with EcoSystem 1 FCJ ECO FCJS ECO 0796554 or higher 3 per EcoSystem link Energi Savr NodeTM unit with EcoSystem QSN 1ECO S QSN 2ECO S QSN 2ECO PS120 UQSN 1ECO S UQSN 2ECO S 9 027 or higher 64 per EcoSystem link GRAFIK Eye QS unit with EcoSystem QSGRJ _E QSGR _E 9 009 or higher 64...

Page 11: ...Numbers LED Dimming Driver Architectural Dimming 369883c 11 09 13 16 Wiring continued Continuous LED Light Run In a continuous LED light run it is best to connect the load wires in the middle of the LED light run Please consult load manufacturer best practices for any additional consideration in load installation When connecting several LED light homeruns ensure that the wire lengths and wattages ...

Page 12: ...er up to 277 V to EcoSystem control inputs EcoSystem Digital Link Wiring EcoSystem Digital Link terminals accept 20 AWG to 12 AWG 0 50 mm2 to 2 5 mm2 solid or stranded copper wire per terminal Make sure that the supply breaker to the drivers and EcoSystem Digital Link Supply is OFF when wiring E1 and E2 terminals of the drivers can be daisy chained as shown to the right Using two different colors ...

Page 13: ...amp locations Convient aux emplacements humides Use 20 12 AWG wire only Utiliser un fil de 0 50 2 5 mm seulement WARNING Shock hazard May result in serious injury or death Disconnect power before opening top lid servicing or installing AVERTISSEMENT Danger d électrocution Peut causer de graves lésions ou le décès de la personne Couper l alimentation du disjoncteur avant de procéder à l ouverture d...

Page 14: ...residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can ...

Reviews: