background image

      52 Railroad Ave                                                    www.preciseled.com                       

      Valley Stream, NY 11580                                          [email protected]            

File Name: DRIV-LP-24V-96W SPEC A02   JAN. 5, 2020                                                                                                                                Page 

 

We reserve the right to change specifications without prior notice.

   

2020

 

PreciseLED 

DRIV-LP-24V-96W

Project Name:
Fixture Type:

Lutron LP Serise 24VDC, 5-96Watts 3-Wire/digital EcoSystem

120/277V 0.1% Dimming LED Driver

Hi-lume

®

 Premier 0.1% Constant Voltage Driver (L3D0)

®

S P E C I F I C AT I O N   S U B M I T TA L

Page

Job Name:

Job Number:

Model Numbers:

LED Dimming Driver

Architectural Dimming

369883c   1   09.13.16

The Hi-lume

®

 Premier 0.1% Constant Voltage Driver 

(L3D0) is a high-performance LED driver capable of 
controlling up to 96 W of 24 V

constant voltage 

loads. This driver provides smooth and continuous 
dimming down to 0.1% low-end. It is ideal for use with 
strip lighting in applications such as coves, under or 
over cabinet lighting and pathway lighting. The driver is 
UL

®

 Listed with an integrated wiring compartment and 

can be mounted up to 150 ft (45 m) away from the 
load.

Features

• Continuous, flicker-free dimming from 100% to 0.1% 

1

.

• Soft-on, Fade-to-Black

TM

 

operation for EcoSystem

®

 

controls: fades smoothly between 0% and 0.1% when 
turned on and off for an incandescent like experience. 

2

• PWM dimming meets IEEE1789 over the entire 

dimming range.

• UL

®

 Listed for United States and Canada (cULus

®

).

• NOM certified for Mexico.
• Field Adjustment Knob offers customer low-end light 

output tuning for better fixture-to-fixture matching. 

• Guaranteed dimming performance when used with 

Lutron

®

 controls:

  –  HomeWorks

®

 QS, Energi Savr Node

TM

 units with 

EcoSystem

®

 

controls, GRAFIK Eye

®

 QS with 

EcoSystem

®

 

controls, PowPak

®

 with EcoSystem

®

 

dimming modules, PowPak

®

 with EcoSystem

®

 

wireless fixture controls, and Quantum

®

 systems, 

allowing for integration into a planned or existing 
EcoSystem

®

 lighting control solution.

  –  Lutron

®

 3-wire controls and interfaces.

• Protected from miswires of input power, up to 277 V

~

to EcoSystem

®

 control inputs.

..

•  Rated lifetime of 50,000 hours at 40 °C (104 °F) 

ambient temperature and maximum loading.

• FCC Part 15 compliant for commercial applications at 

120–277 V

and residential applications at 120 V

~

.

• In rush limiting allows full loading of circuit breakers 

without nuisance tripping.

1

  Light output at 0.1% depends on installation and light engine efficacy.

2

  Soft-on, Fade-to-Black

TM

 dimming technology is not available for 3-wire controls.

Hi-lume

®

 Premier 0.1% EcoSystem

®

 / 3-wire 

Constant Voltage 24 V

-

 LED Driver with 

Soft-on, Fade-to-Black

TM

• 100% end-of-line performance tested at a Lutron

®

 

factory.

• RoHS compliant.
• Restores all settings after power failure.
• Barrier provided for Class 2 separation in the wiring 

compartment.

• Redundant connections on line and control terminals 

for easy daisy chain wiring.

• Redundant connections on output terminals allow for 

easy wiring of two LED load home runs.

• Class 2 output designed to withstand hot swap.
• For more information please visit: www.lutron.com

Hi-lume

R

 Premier 0.1% Constant Voltage Driver (L3D0)  

5.5 in (140 mm) W x 2.0 in (51 mm) H x 10.5 in (267 mm) L

50016452a

lutron.com

0 784276

166027

120 - 277 

V      50 / 

60 Hz   0,

92 - 0,40 A

   110 W M

ax

Soft-on, Fade-to-Black

TM

EcoSyste

m

TM

 3-wire Co

nstant Vo

ltage LED

 Driver

LED Drive

r 4RM5

L3D0-96W24V-U

Allumage 

doux, fondu 

au noir

EcoSyste

m

TM

Pilote 3-fil

 tension c

onstante p

our DEL

USA / Can

ada: 1.844

.LUTRON

1 (1.844.5

88.7661)

Input | En

trée:

Output | S

ortie:

24 V      4

 A Max   C

lass 2

B2

Warranty 

void if inne

r plastic co

ver is rem

oved.

Garantie a

nnulée si l

e couverc

le plastiqu

e intérieur

 est ouver

t.

Field Adju

stment Kn

ob

Bouton de

 Réglage p

our utilisat

ion en cha

ntier

Hi-lume

®

Premier 0.1%

Suitable fo

r damp loc

ations.

Convient a

ux emplac

ements hu

mides.

Use 20 - 1

2 AWG wi

re only.

Utiliser un 

fil de 0,50 

- 2,5 mm² 

seulement

.

WARNING

:

 Shock ha

zard. May r

esult in se

rious injury

 or death. 

Disconnec

t power be

fore openi

ng top lid, servicing or installing.

AVERTISSEMENT

 :

 Danger d'

électrocuti

on. Peut c

auser de g

raves

lésions ou

 le décès d

e la person

ne. Coupe

r l’alimenta

tion du

disjoncteu

r avant de

 procéder à l

’ouverture

 de couver

cle supérie

ur,

au montag

e ou à l’en

tretien de l

’installation

.

Pats | Bre

vets: 7,91

1,156

Lid screws

: 8-32 x 3/

8” thread-

rolling, ser

rated

Vis du cou

vercle: 8-3

2 x 3/8” ro

ulage de f

ilets, dente

lées

1/4 in (6,5 mm)

Cu Al

1

by 

Lutron

Summary of Contents for DRIV-LP-24V-96W

Page 1: ...ing FCC Part 15 compliant for commercial applications at 120 277 V and residential applications at 120 V In rush limiting allows full loading of circuit breakers without nuisance tripping 1 Light output at 0 1 depends on installation and light engine efficacy 2 Soft on Fade to BlackTM dimming technology is not available for 3 wire controls Hi lume Premier 0 1 EcoSystem 3 wire Constant Voltage 24 V...

Page 2: ...ower failure Typical standby power consumption 0 25 W at 120 V and 0 4 W at 277 V Open circuit protected output Short circuit and overload protected output Output 24 V constant voltage at high end Output Load Range 25 W to 96 W at high end PWM dimming frequency meets IEEE1789 at all dim levels Power Factor 0 95 at maximum power Total Harmonic Distortion THD 20 at maximum power Performance continue...

Page 3: ...essed if service or troubleshooting is necessary Driver is grounded by terminal connection Terminal blocks on the driver accept solid or stranded wire per terminal from 20 AWG to 12 AWG 0 50 mm2 to 2 5 mm2 Maximum wire length between the LED driver and the start of the linear strip for different wire sizes is listed below The table below can be used independently of line voltage powering the LED D...

Page 4: ...ge V Input Current1 A Typical Power Factor1 Typical THD1 Output Power1 W Output Voltage1 V 3 Wire or EcoSystem Control2 For 24 V Constant Voltage LED Loads L3D0 96W24V U 120 0 92 0 99 7 5 25 96 24 277 0 40 0 97 11 25 96 24 1 At maximum output power 2 For wiring options see Wiring section pages 9 11 NOTE Specifications are subject to change without notice Power Factor vs Output Power THD vs Output P...

Page 5: ...ie 24 V 4 A Max Class 2 B2 Warranty void if inner plastic cover is removed Garantie annulée si le couvercle plastique intérieur est ouvert Field Adjustment Knob Bouton de Réglage pour utilisation en chantier Hi lume Premier 0 1 Suitable for damp locations Convient aux emplacements humides Use 20 12 AWG wire only Utiliser un fil de 0 50 2 5 mm seulement WARNING Shock hazard May result in serious in...

Page 6: ...oSystem 120 277V 0 1 Dimming LED Driver Hi lume Premier 0 1 Constant Voltage Driver L3D0 SPECIFICATION SUBMITTAL Page Job Name Model Numbers LED Dimming Driver Architectural Dimming 369883c 6 09 13 16 Mounting Options1 2 1 Any other mounting configuration will require additional mechanical support Improper installation may result in hazards to personnel or property 2 Mount the driver in a position ...

Page 7: ... 16 Barrier Installation and Driver Spacing Requirements Measurements are shown as in mm Optional barrier can be placed either between the input and control terminals Option 1 when the EcoSystem links are wired as Class 2 or between the control and output terminals Option 2 when EcoSystem links are wired as Class 1 For 3 wire control barrier could be placed in either location See Lutron Applicatio...

Page 8: ... Utiliser un fil 0 50 2 5 mm2 seulement Warranty void if inner plastic cover is removed Garantie annulée si le couvercle plastique intérieur est ouvert B2 LISTED LED Driver 4RM5 Hi lume Premier 0 1 WARNING Shock hazard May result in serious injury or death Disconnect power before opening top lid servicing or installing AVERTISSEMENT Danger d électrocution Peut causer de graves lésions ou le décès d...

Page 9: ... 16 1 19 NF 103P NF 103P 277 1 8 1 14 Skylark dimmer SF 10P SF 12P 277 1 8 1 14 SF 103P SF 12P 277 3 1 8 1 14 Diva dimmer DVF 103P DVF 103P 277 1 8 1 14 DVSCF 103P DVSCF 103P 277 1 8 1 14 Ariadni dimmer AYF 103P AYF 103P 277 1 8 1 14 Maestro dimmer MAF 6AM MAF 6AM 277 1 6 1 14 MSCF 6AM MSCF 6AM 277 1 6 1 14 Maestro Wireless dimmer MRF2 F6AN DV 1 6 1 14 RadioRA 2 dimmer RRD F6AN DV 1 6 1 14 Dual vo...

Page 10: ...Module with EcoSystem RMJ ECO32 DV B URMJ ECO32 DVB 5 9 or higher 32 per EcoSystem link PowPak Wireless Fixture Control with EcoSystem 1 FCJ ECO FCJS ECO 0796554 or higher 3 per EcoSystem link Energi Savr NodeTM unit with EcoSystem QSN 1ECO S QSN 2ECO S QSN 2ECO PS120 UQSN 1ECO S UQSN 2ECO S 9 027 or higher 64 per EcoSystem link GRAFIK Eye QS unit with EcoSystem QSGRJ _E QSGR _E 9 009 or higher 64...

Page 11: ...Numbers LED Dimming Driver Architectural Dimming 369883c 11 09 13 16 Wiring continued Continuous LED Light Run In a continuous LED light run it is best to connect the load wires in the middle of the LED light run Please consult load manufacturer best practices for any additional consideration in load installation When connecting several LED light homeruns ensure that the wire lengths and wattages ...

Page 12: ...er up to 277 V to EcoSystem control inputs EcoSystem Digital Link Wiring EcoSystem Digital Link terminals accept 20 AWG to 12 AWG 0 50 mm2 to 2 5 mm2 solid or stranded copper wire per terminal Make sure that the supply breaker to the drivers and EcoSystem Digital Link Supply is OFF when wiring E1 and E2 terminals of the drivers can be daisy chained as shown to the right Using two different colors ...

Page 13: ...amp locations Convient aux emplacements humides Use 20 12 AWG wire only Utiliser un fil de 0 50 2 5 mm seulement WARNING Shock hazard May result in serious injury or death Disconnect power before opening top lid servicing or installing AVERTISSEMENT Danger d électrocution Peut causer de graves lésions ou le décès de la personne Couper l alimentation du disjoncteur avant de procéder à l ouverture d...

Page 14: ...residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can ...