2. SPECIFICATIONS

2-1 General Specifications

Circuit

Custom one-chip of microprocessor LSI
circuit.

Display

LCD size : 52 mm x 38 mm (Dot Matrix)
LCD with green backlight ( ON/OFF ).

Measurement

CO2 (Carbon dioxide )
Humidity
Dew point Temp., Wet bulb Temp.
Temperature 

Sensor

CO2

NDIR

* Nondispersive infrared sensor

structure

Humidity

Precision capacitance sensor

Temp.

Precision thermistor

Datalogger

Auto 

 2 sec to 3600 sec.

Sampling Time

@ Sampling time can set to 1 second,

Setting range

but memory data  may loss.

Manual 

Push the data logger button 
once will save data one time.

@ Set the sampling time to 

0 second.

@ Manual mode, can also select the 

1 to 99 position ( Location ) no.

Data error no.

0.1% of total saved data max.

Memory Card

SD memory card. 1 GB to 16 GB.

Advanced 

 * SD memory card Format

setting

 * Set clock time 

 * Set sampling time 

@ main setting

 * Auto power OFF management

 * Set beep Sound ON/OFF

 * Decimal point of SD card setting

 * Temp. unit setting

 * Alarm value setting

 * Altitude value setting

2

All manuals and user guides at all-guides.com

Summary of Contents for CO2-9914SD

Page 1: ...h SD CARD DATA RECORDER marks a step forward for you into the field of precision measurement Although this Meter is a complex and delicate instrument its durable structure developed Please read the fo...

Page 2: ...tion before execute datalogger function 11 6 2 Auto Datalogger Set sampling time 1 second 12 6 3 Manual Datalogger Set sampling time 0 second 13 6 4 Check time information 13 6 5 Check sampling time i...

Page 3: ...sition 99 Air quality measurement application multi function CO2 Carbon dioxide Humidity Dew Wet temperature measurement CO2 range 0 to 10 000 ppm x 1 ppm Humidity range 10 to 95 RH x 0 1 RH Dew point...

Page 4: ...c Sampling Time Sampling time can set to 1 second Setting range but memory data may loss Manual Push the data logger button once will save data one time Set the sampling time to 0 second Manual mode c...

Page 5: ...Normal operation w o SD card save measure data and LCD Backlight is OFF ment Approx DC 136 5 mA When SD card save the data and LCD Backlight is OFF Approx DC 166 mA Humidity Normal operation w o SD ca...

Page 6: ...Resolution 1 ppm Carbon Accuracy 40 ppm dioxide 1 000 ppm 50ppm 3 of reading 23 5 1 000 ppm 3 000 ppm 50ppm 5 of reading typically 3 000 ppm 10 000 ppm Repeatability 20 ppm 3 000 ppm Temperature Rang...

Page 7: ...perature measurement Wet bulb Temp Humidity Range 21 6 to 50 0 Resolution 0 1 Range 6 9 to 122 0 Resolution 0 1 Remark Wet bulb display value is calculated from the Humidity Temp measurement automatic...

Page 8: ...3 FRONT PANEL DESCRIPTION Fig 1 6 All manuals and user guides at all guides com...

Page 9: ...8 Logger Button Enter Button 3 9 Stand 3 10 Battery Compartment Cover 3 11 Battery Cover Screw 3 12 Tripod Fix Nut 3 13 CO2 Humidity Probe Input Socket 3 16 DC 9V Power Adapter Input Socket 3 17 Rese...

Page 10: ...obes but the meter Display can show the one probe two kind Function measurement value at the same time c If the meter already plug the above 1 probes when make the SD card to record the data it can sa...

Page 11: ...ay show four functions reading At the same time test four kinds of functions and display show four functions reading At the same time test tow kinds of functions and display show two functions reading...

Page 12: ...the Hold Button 3 3 Fig 1 once then the display will show the REC symbol only execute the memory function continuously b Press the REC Button 3 4 Fig 1 again the REC MIN symbol along with the minimum...

Page 13: ...strongly do not use memory cards that have been formatted by other meter or by a computer Reformat the memory card with your meter c Time setting If the meter is used at first time it should to adjust...

Page 14: ...5 b Pause the datalogger During execute the Datalogger function if press the Logger Button 3 8 Fig 1 once will pause the Datalogger function stop to save the measuring data into the memory circuit te...

Page 15: ...the Button 3 5 Fig 1 the lower no position no will flashing It can use the Button 3 5 Fig 1 or Button 3 6 Fig 1 to set the measuring Location no 1 to 99 for example room 1 to room 99 to identify the m...

Page 16: ...ll generate a new file name C2A01001 XLS After exist the Datalogger then execute again the data will save to the C2A01001 XLS until Data column reach to 30 000 columns then will generate a new file fo...

Page 17: ...the computer 3 Power ON the computer and run the EXCEL software Down load the saving data file for example the file name AQB01001 XLS AQB01002 XLS from the SD card to the computer The saving data will...

Page 18: ...16 All manuals and user guides at all guides com...

Page 19: ...r Minute Second P OFF Auto power OFF management BEEP Set beeper sound ON OFF DEC Set SD card Decimal character T C F Set the Temp unit to or ALARM Set the alarm value ALTITUDE Set the altitude value E...

Page 20: ...hat already saving into the SD card 8 2 Set clock time Year Month Date Hour Minute Second When the upper display show DATE 1 Use the Button 3 5 Fig 1 or Button 3 6 Fig 1 to adjust the value Setting st...

Page 21: ...ute Second value Remark The adjusted value will be flashed 2 After set all the sampling time value Hour Minute Second press the SET Button 3 7 Fig 1 once will save the sampling value with default then...

Page 22: ...ta structure of SD card is default used the as the decimal for example 20 6 1000 53 But in certain countries Europe is used the as the decimal point for example 20 6 1000 53 Under such situation it sh...

Page 23: ...2 After set the Alarm value press the Enter Button 3 8 Fig 1 will save the Alarm value with default 3 When measurement value Alarm set value the buzzer will sound for warning Remark For the O2 functi...

Page 24: ...pensation value feet 2 After set the Alarm value press the Enter Button 3 8 Fig 1 will save the CO2 height compensation feet value with default 9 POWER SUPPLY from DC ADAPTER The meter also can supply...

Page 25: ...fix the problem The system RESET procedures will be either following method During the power on use a pin to press the Reset Button 3 17 Fig 1 once a while will reset the circuit system 12 RS232 PC SE...

Page 26: ...data probe 2 5 When send the Temp CO2 data probe 2 6 D12 D11 Annunciator for Display 01 PPM 19 RH 04 02 PPM_CO2 G4 _Dew G5 _WET G7 Dew G6 WET G8 D10 Polarity 0 Positive 1 Negative D9 Decimal Point DP...

Page 27: ...d structure already get patent or patent pending in following countries Germany Nr 20 2008 016 337 4 JAPAN 3151214 CHINA ZL 2008 2 0189918 5 ZL 2008 2 0189917 0 25 151211 CO29914SD All manuals and use...